3.6
Signals and Remote Capabilities
3.6.1 Dry Contacts
The dry contact can be used to signal a remote device in event
of the following major alarms:
•
Lamp Fault
•
Ballast (Controller) Fault
•
UV Sensor Fault
•
Low UV Fault
Connection Logic Chart
Wire
Output Terminal
UV System in
Normal Operation
UV System in Major
alarm/not powered on
RED
N.O. (Normally Open
Contact)
The Electrical path
between these
contacts are closed
The Electrical path
between these contacts
are open
BLACK
COM. (Common)
COM. (Common)
The Electrical path
between these
contacts are open
The Electrical path
between these contacts
are closed
GREEN
N.C. (Normally Closed
Contact)
3.6.2 4-20 mA Interface
An optional 4-20 mA
interface allows the user to read the current
output by the UV sensor or the flow meter. The interface can be used
to send information to other monitoring systems.
4.0
C
ERTIFICATIONS
All Adenovirus systems are tested and certified to USEPA UVDGM, UL, CE, RoHS, and
Low Lead standards.