Viper d1200.1 Скачать руководство пользователя страница 1

model

d600.1

d1200.1

Содержание d1200.1

Страница 1: ...model d600 1 d1200 1...

Страница 2: ...2 2002 Directed Electronics Inc...

Страница 3: ...uality audio reproduction Viper Audio power amplifiers come with a two year limited warranty if installed by an authorized Viper dealer If not installed by an authorized dealer Viper Audio power ampli...

Страница 4: ...improper service or other causes not arising out of defects in materials or construction ALL WARRANTIES INCLUDING BUT NOT LIMITED TO EXPRESS WARRANTY IMPLIED WARRANTY WARRANTY OF MERCHANTABILITY FITN...

Страница 5: ...ntary MOSFET outputs stable into 1 ohm loads Thermal DC offset reverse polarity and short circuit protection with status LED Master slave RCA jack functions support two amps bridged to one load Top mo...

Страница 6: ...r power connection within 8 to 10 inches of the battery terminal Use a fuse or circuit breaker rated slightly more than the on board fuse s of the amplifier s The gauge of power wire used should take...

Страница 7: ...ehicle may be picked up in the system Power and speaker wire connections on Viper Audio power amplifiers are performed with the use of specially designed connectors that allow for ease of wire termina...

Страница 8: ...tp pu ut t J Ja ac ck k This output sends an out of phase signal to a slave amplifier when connected in the External Synced Bridged combi nation Refer to the Combined Amplifiers section of this guide...

Страница 9: ...These fuse s protect the amplifier against internal elec trical damage and are meant to protect the amplifier only All other power connections should be fused at the source 5 1 12 2 V Vo ollt t P Po o...

Страница 10: ...10 2002 Directed Electronics Inc FIGURE 2 AMPLIFIER CONNECTIONS d600 1 REAR 2 1 5 4 6 3 FIGURE 3 AMPLIFIER CONNECTIONS d1200 1 REAR 2 1 5 4 6 3...

Страница 11: ...active crossover 3 V Va ar riia ab blle e B Ba as ss s E EQ Q Adds 0 to12db of additional boost to the subwoofer output when active 4 S Su ub b P Ph ha as se e A Ad djju us st tm me en nt t Controls t...

Страница 12: ...top If the window will not release easily use a small flat tool to pry it loose Pry slowly and evenly from several points to avoid deforming or cracking the window 2 Apply two of the precut pieces of...

Страница 13: ...subwoofer connection bottom view Two subwoofer connection bottom view N NO OT TE E The dual and subout terminals of the d600 1 d1200 1 are paralleled internally and the combined load impedance should...

Страница 14: ...onnection diagrams N NO OT TE E One master amplifier can control up to three slave amplifiers in this combination Multiple identical master slave combinations can be added to any given system External...

Страница 15: ...e e S Su ub b L Le ev ve ell C Co on nt tr ro oll Connect the Remote Sub Level Control to the master amplifier only The master amplifiers subwoofer gain is used to set the overall gain for all synced...

Страница 16: ...of the d600 1 d1200 1 are paralleled internally and the combined load imped ance should be taken into consideration when connecting multiple subwoofers SUB LEVEL MIN MAX INPUT I O SLAVE IN SYNC OUT BR...

Страница 17: ...trol is used to set the overall gain for both amplifiers and then the Remote Sub Level control can adjust the gain of both amplifiers 4 S Siig gn na all C Co on nn ne ec ct tiio on n Connect an RCA ca...

Страница 18: ...R L SLAVE MASTER REMOTE 1 2 2 Do Not Use 3 Do Not Use Master Slave 4 N NO OT TE E The dual and subout terminals of the d600 1 d1200 1 are paralleled inter nally and the combined load impedance should...

Страница 19: ...evel Control cable can be divided several times to connect to each master amplifier This can be accomplished by using one or more Directed Remote Sub Level cable splitters Standard single to double ph...

Страница 20: ...head unit to the 3 4 volume setting or until you start to hear distortion or clipping If you hear distortion before you reach the 3 4 volume setting of your head unit reduce the gain setting on the am...

Страница 21: ...VDC Fusing and Power 60A 90A Minimum Cable Requirements AWG 8 4 Per amp trunk mounted 750 1500 watts watts 400 800 watts watts 0 6 THD 0 7 600 1200 watts watts 0 8 THD 0 9 800 1600 watts watts 1200 2...

Страница 22: ......

Страница 23: ......

Страница 24: ...eld of advanced electronic technology Directed is ISO 9001 registered Directed is committed to delivering world class quality products and services that excite and delight our customers Directed Elect...

Отзывы: