background image

10 

1.

 

Place charger and machine in a well ventilated area. 

2.

 

Turn machine off (47). 

3.

 

Take away the recovery tank (2), Exposing battery compartment. 

4.

 

Plug the charging cable to the grounded wall outlet (100v~240v).. 
Connect the charging cable to the machine socket. 

5.

 

The charging indicator light (30) turn on means It is in charging, green light means battery charging 
is completed. 

6.

 

Upon  the  completion  of  charging,  first  unplug  the  charging  cable  from  the  wall  outlet  and  then 
disconnect from machine. 

7.

 

Replace the recovery tank. 

 

NOTE 

For further information about the operation of the battery charger (29), see the relevant paragraph. 

 

SQUEEGEE CLEANING 

 

NOTE 
The squeegee must be clean and its blades must be in good condition in order to     
getting a good drying performance. 

 

CAUTION! 

It is advisable to wear protective gloves when cleaning the squeegee because there may be sharp debris. 

SQUEEGEE BLADE CHECK AND REPLACEMENT 

1. Take off the squeegee as shown in the previous paragraph. 
2. Check to see if the edge of the front/rear blades are cracked or split, if necessary replace them with 
new. 
3. Unscrew six the thumb nut (37) to get off the blades. 
4. Check the front/rear blades for integrity, cut and tears. If they are not adequate, overturn or replace 
them. 
5. Install the squeegee in the reverse order of removal. 

BRUSH /PAD DRIVER CLEANING 

 

CAUTION

 

It is advisable to wear protective gloves when cleaning the brush/pad because there may be sharp debris. 

 

1. Remove the brush/pad as shown in the previous paragraph. 
2. Clean and wash the brush/pad with water and detergent. 
3. Check the brush bristles for integrity and wearing status; if necessary, replace the brush. 
4. Check the pad for wearing status; if necessary, replace the pad driver. 

TANK/VACUUM GRID WITH FLOAT CLEANING AND COVER 

GASKET CHECK 

 

CAUTION

 

It is advisable to wear protective gloves when cleaning the tank and vacuum/suction assembly because 

there may be sharp debris. 

 

USER MANUAL 

Содержание AS380/15B-AU

Страница 1: ...VF89865 REV 01 2015 7 13 AS380 15B AU User Manual Original instructions Company information www vipercleaning eu info eu vipercleaning com...

Страница 2: ......

Страница 3: ...WKH PDFKLQH FRQIRUPLW ZLWK WKH ODZ LQ IRUFH NOTE Two copies of the original declaration of conformity are provided together with the machine documentation IDENTIFICATION DATA The machine serial numbe...

Страница 4: ...ubber dryer Instructions for use Manual Electronic battery charger manual if installed Scrubber dryer Spare Parts List SAFETY The following symbols indicate potentially dangerous situations Always rea...

Страница 5: ...battery charging produces highly explosive hydrogen gas During battery charging lift the recovery tank and perform this procedure in well ventilated areas and away from naked DPHV WARNING Carefully r...

Страница 6: ...95 KHQ XVLQJ RRU FOHDQLQJ GHWHUJHQWV IROORZ WKH LQVWUXFWLRQV RQ WKH ODEHOV RI WKH GHWHUJHQW ERWWOHV 7R KDQGOH RRU FOHDQLQJ GHWHUJHQWV ZHDU VXLWDEOH JORYHV DQG SURWHFWLRQV Do not use the machine as a m...

Страница 7: ...tank 2 as shown in the relevant paragraph 3 Unscrew the bolt from batteries 16 then remove or change 4 Install the batteries on the machine according to the diagram below 5 Install the recovery tank...

Страница 8: ...rotate the brush pad clockwise until it is released from drive wheel hub WARNING Do not turn on the machine in this position as below The brush pad could disengage and cause injury Squeegee installati...

Страница 9: ...ain 2 Rinse the solution tank with clean water after every use This will help prevent chemical build up and clogging of the solution lines 3 Screw up the drain cap 22 Recovery tank draining NOTE Recov...

Страница 10: ...Remove the brush pad holder 2 Empty the tanks as shown in the previous parsagraph 3 Perform the daily maintenance procedures see the maintenance chapter 4 Store the machine in a clean and dry place wi...

Страница 11: ...or carbon brush check or replacement 2 Vacuum system motor carbon brush check or replacement 2 1 And after the first 8 working hours 2 This maintenance procedure must be performed by an authorized vip...

Страница 12: ...harp debris SQUEEGEE BLADE CHECK AND REPLACEMENT 1 Take off the squeegee as shown in the previous paragraph 2 Check to see if the edge of the front rear blades are cracked or split if necessary replac...

Страница 13: ...ce them MACHINE STRUCTURE 1 Recovery tank lid 2 Recovery tank 3 Solution tank 4 Brush cover 5 Protective rollers 6 Brush 7 Front handle shell 8 Control panel 9 Rear handle shell 10 Handle rubber 11 Ha...

Страница 14: ...hose 35 Squeegee wheels 36 Axle 37 Thumb nut 38 Vacuum system motor 39 Brush motor 40 Drive belt 41 Belt 42 Squeegee rotation plate 43 Squeegee lift plate 44 Squeegee fixing plate 45 Motor fixing pla...

Страница 15: ...13 USER MANUAL...

Страница 16: ...ion tank capacity 15L Recovery tank capacity 15L Wheel diameter 254MM Brush motor data 24V 250W Vacuum motor data 24V 300W Electromagnetic valve data 24V Maximum gradient 2 Sound lever 68 dBA Batterie...

Страница 17: ...r key board Vacuum system motor does not work brush indicator lights 53 flash The vacuum system motor is overloaded Check the vacuum system motor The suction power is insufficient The recovery tank is...

Страница 18: ...Ltd Unit 1 13 Bessemer Street Blacktown NSW 2148 Phone 1300 556 710 E mail Warranty au nilfisk com NEW ZEALAND Nilfisk Limited Suite F Building E 42 Tawa Drive Albany Auckland 0632 Phone 64 9414 1996...

Страница 19: ...Company information www vipercleaning eu info eu vipercleaning com...

Отзывы: