26
©
2005
Directed Electronics, Inc. all rights reserved
This jumper is used to determine the indicator light flash output polarity. In the (+) position, the
on-board relay is enabled and the unit will output (+)12V on the WHITE wires, H11/12. In the (-)
position, the two WHITE wires will supply a (-) output suitable for driving negative switching
indicator circuits.
Ultrasonic Sensor
The built-in remotely adjustable Ultrasonic sensor is used to provide coverage of a vehicle’s interior
cabin area. The sensors detect movement inside the vehicle by sensing air disturbance. They should
trigger the alarm if a thief has gained access to the interior of your vehicle.
Mounting the Control Module and Transducers
1. Choose a location under the dashboard for the control module that is close enough that the
transducers will reach the top of the A-pillar on both driver and passenger sides.
2. One transducer is longer than the other, so mount the transducer with the longest harness
furthest from the control module. Use the screws provided or insert the mounting tabs between
the dashboard and windscreen pillar.
3. Angle the sensors towards the top centre of the rear window. If mounted at the top of the A-
pillars make sure the transducers position does not affect use of the sun visor.
4. Route the sensor cables to the alarm control module and plug-in. It will report zone 2 if
triggered.
IMPORTANT!
DO NOT connect the WHITE indicator wires to a negative switching
vehicle circuit before changing the programming jumper to the negative polarity
position or damage to the vehicle may occur.
NOTE:
Current handling capacity for H11 and H12 Indicator circuits is 10 amps