Vintage Air 491252 Скачать руководство пользователя страница 7

7

www.vintageair.com

901356 REV A 02/27/19, PG 7 OF 8

Operation of Controls

Adjust to desired

speed.

Blower Speed

Adjust to desired

speed.

Adjust to desired

mode position 

(DASH position 

recommended).

Adjust to desired

speed.

Adjust to DEFROST position for maximum defrost, or 

between FLOOR and DEFROST positions for a bi-level 

blend (Compressor is automatically engaged).

Adjust to desired 

temperature.

For A/C operation, adjust to

coldest position to engage 

compressor (Adjust between 

HOT and COLD to reach

desired temperature).

A/C Operation

Heat Operation

Defrost/De-fog Operation

On Gen IV systems with three lever/knob controls, the temperature control toggles between heat and A/C 

operations. To activate A/C, move the temperature lever/knob all the way to cold and then back it off to the desired 

vent temperature. For heat operation, move the temperature lever/knob all the way to hot and then adjust to the 

desired vent temperature. The blower will momentarily change speed, each time you toggle between operations, to 

indicate the change. 

Blower Speed

Blower Speed

This lever/knob controls

blower speed, from 

OFF to HI.

This lever/knob controls 

the mode positions,

from DASH to FLOOR

to DEFROST, with a 

blend in between.

This lever/knob controls

the temperature,

from HOT to COLD.

Blower Speed

Mode Control

Temperature Control

Temperature Control

Temperature Control

Temperature Control

Mode Control

Mode Control

Mode Control

For maximum heating, adjust 

to hottest position (Adjust 

between HOT and COLD to 

reach desired temperature).

Adjust to desired

mode position

(FLOOR position 

recommended).

Blower 

Speed

Mode 

Control

Temperature 

Control

Содержание 491252

Страница 1: ...pany Streamline 3 Knob Horizontal Wide Panel Black Anodized 491252 901356 REV A 02 27 19 PG 1 OF 8 18865 Goll St San Antonio TX 78266 Phone 800 862 6658 Sales sales vintageair com Tech Support tech vi...

Страница 2: ...with the heater on before evacuating Leak check and charge to specifications The Proper Amount of Refrigerant is Critical to Proper System Operation Vintage Air Recommends Our System be Charged by We...

Страница 3: ...rizontal Wide Control Panel Black Anodized Gen IV Universal Control Harness Before beginning installation open all packages and check contents of shipment Please report any shortages directly to Vinta...

Страница 4: ...nly hold the panel against the dash They do not locate the panel laterally If the opening is oversized the panel may shift during use Install the control panel face through the opening in the dash Pla...

Страница 5: ...el wiring harness into the control panel and the ECU on the evaporator See Figure 4 below Wire according to the wiring diagram on Page 6 5 6 Figure 4 Control Panel Face Dash Control Panel PC Board Ass...

Страница 6: ...VUR 232002 VUA CIRCUIT BREAKER 30 AMP WIDE OPEN THROTTLE SWITCH OPTIONAL DASH LAMP IF USED Dash Lamp Is Used Only With Type 232007 VUR Harness Warning Always Mount Circuit Breaker As Close to the Batt...

Страница 7: ...temperature lever knob all the way to cold and then back it off to the desired vent temperature For heat operation move the temperature lever knob all the way to hot and then adjust to the desired ven...

Страница 8: ...ontal Wide Black Anodized No 1 2 Qty 1 1 Part No 491253 232007 VUR Description Streamline 3 Knob Horizontal Wide Control Panel Black Anodized Gen IV Universal Control Harness 1 2 NOTE Images may not d...