Control Panel Dimensions
Control Panel Installation
Select a suitable location for the control panel, considering heater control valve location, wiring harness length
and operator convenience.
After selecting a location for the control panel, mask the area 2 ½” (tall) x 6 ½” (wide).
Using the dimensions provided above, mark or scribe the control panel opening location onto the dash.
When you are certain that your dimensions and markings are correct, cut the dash to make the control
panel opening.
NOTE: Measure twice. Cut once. This opening MUST be a precise fit. Cut the opening
undersize, and then file to fit. The mounting screws only hold the panel against the dash. They do
not locate the panel laterally. If the opening is oversized, the panel may shift during use.
Install the control panel face through the opening in the dash. Place the control panel PC board assembly
behind the dash, and secure it to the control panel face using the (4) 8-32 x 3/8” screws (See Figures 1 &
2, below, and Figure 3, Page 5). NOTE: When tightening the control panel mounting screws, hand
tighten until the screw contacts the back side of the dash. Then, using a screwdriver, tighten an
additional 1/2 turn. Do not over tighten, as this may cause damage to the PC board or the dash.
1.
2.
3.
4.
(4) Control Panel
Mounting Screws
Control Panel PC
Board Assembly
Control
Panel Face
Figure 1
Figure 1
5.318”
4.250”
1.068”
Opening
in Dash
(4) Control Panel
PC Board Mounting
Screws
Figure 2
Level This Line
Thread Into Back
Side of Control
Panel Face