8

901300-VUZ REV I 10/29/14, SLIMLINE HCD PG 8 OF 13

TYPICAL HOSE ROUTING DIAGRAM

DIRECTION OF R

EFRIGERANT FLOW INDICATED BY ARROWS

RECEIVER/DRIER

(NOTE FLOW DIRECTION)

#6 LIQUID LINE

SAFETY SWITCH

BINARY (ENGINE DRIVEN FAN)

TRINARY (ELECTRIC FAN)

COMPRESSOR

CONDENSER

# 8 DISCHARGE

HOSE

EVAPORATOR

# 10 SUCTION HOSE

Содержание 11300-VUZ-A

Страница 1: ...SLIMLINE HEAT COOL DEFROST 11300 VUZ A 11400 VUZ A 901300 VUZ REV I 10 29 14 SLIMLINE HCD PG 1 OF 13 an ISO 9001 2008 Registered Company OFF LO MED HI ENCO A C HEAT DEF C...

Страница 2: ...9 10 11 12 13 COVER TABLE OF CONTENTS PACKING LIST INFORMATION PAGE DEFROST DUCT INSTALLATION INSTALLATION INSTALLATION CONT HOSE ROUTING O RING FITTING INSTRUCTIONS HEATER HOSE INSTALLATION WIRING DI...

Страница 3: ...GE AIR WITHIN 15 DAYS AFTER 15 DAYS VINTAGE AIR WILL NOT BE RESPONSIBLE FOR MISSING OR DAMAGED ITEMS 1 2 3 4 5 1 1 1 1 6 55323 VUE A 55423 VUE A 64143 VUE 633810 VUA 63300 VUE 06200 VUE EVAPORATOR SUB...

Страница 4: ...IN HEATER HOSE YOU MUST PURCHASE 8 FEET OF 5 8 DIA HEATER HOSE FROM VINTAGE AIR 31800 VUD OR FROM YOU LOCAL PARTS RETAILER VINTAGE AIR SYSTEMS ARE DESIGNED TO OPERATE WITH R134a REFRIGERANT ONLY USE O...

Страница 5: ...WILL EXIT THE FIREWALL AND OR KICK PANEL AS PLANNED THE HOSES MUST BE RUN EXACTLY THE WAY THEY WILL BE WHEN FINISHED BEFORE CUTTING THEM TO LENGTH DUCT HOSE ROUTING AND A C VENT LOCATIONS SHOULD ALSO...

Страница 6: ...HER FIGURE 2 FIGURE 3 OFF LO MED HI ENCO A C DEF C OFF ECONO C A C MED HEAT DEF ATTACH EVAPORATOR BRACKETS TO EVAPORATOR SEE FIGURE 2 POSITION EVAPORATOR WITH BRACKETS UNDER DASH MARK AND DRILL TWO 2...

Страница 7: ...HESE POINTS WITH A GREASE PENCIL DETERMINE THE BEST LOCATION FOR THE DRIER THAT WILL ALLOW ADEQUATE ROOM FOR THE HOSE AND FITTINGS THAT CONNECT THE DRIER TO THE BULKHEAD FITTING MOUNT THE DRIER KEEP T...

Страница 8: ...TYPICAL HOSE ROUTING DIAGRAM DIRECTION OF REFRIGERANT FLOW INDICATED BY ARROWS RECEIVER DRIER NOTE FLOW DIRECTION 6 LIQUID LINE SAFETY SWITCH BINARY ENGINE DRIVEN FAN TRINARY ELECTRIC FAN COMPRESSOR C...

Страница 9: ...UTCH WIRE RUNS FROM THE THERMOSTAT TO THE COMPRESSOR SAFETY SWITCH AND FROM THE SAFETY SWITCH TO THE COMPRESSOR BE CAREFUL TO ENSURE THAT THIS WIRE IS NOT PINCHED OR IN A POSITION TO RUB ON A SHARP ED...

Страница 10: ...MENDATIONS WILL CAUSE HEATER CORE TO CORRODE PREMATURELY AND POSSIBLY BURST IN THE A C MODE AND OR FREEZING WEATHER VOIDING YOUR WARRANTY CHECK COMPLETE A C ASSEMBLY FOR PROPER OPERATION VINTAGE AIR R...

Страница 11: ...ACUUM SOURCE GREY DEFROSTER DOOR HEATER CONTROL VALVE VACUUM RESERVOIR 87 87 86 86 85 85 30 30 87a 87a BLUE GREEN WHITE GROUND GROUND GROUND WHITE WHITE WHITE LARGE DIODE BLACK GROUND SMALL DIODE MODE...

Страница 12: ...ET TOO COLD AND THE EVAPORATOR IS ICING UP AND RESTRICTING AIRFLOW ALLOW THE ICE TO MELT AND SET THE THERMOSTAT WARMER COUNTERCLOCKWISE 1 8 OF A TURN EACH ADJUSTMENT UNITL THE SYMPTOMS DIMINISH 2 SYMP...

Страница 13: ......

Страница 14: ...5 1 1 1 1 6 55323 VUE A 55423 VUE A 64143 VUE 633810 VUA 63300 VUE 06200 VUE EVAPORATOR SUBCASE H C D w STD LOUVERS EVAPORATOR SUBCASE H C D w BLK LOUVERS FRONT EVAPORATOR BRKT KIT UNIVERSAL DEFROST D...