background image

                                                       

 

                       

 

- 2 -

Important Safety Information 

 
 

 

 
 

 

DO NOT USE A GROUND FAULT INTERRUPTER (GFI). 

 

A DEDICATED 20 AMPCIRCUIT IS HIGHLY RECOMMENDED. 

Содержание WINE-MATE WM-4500SSH

Страница 1: ...Split System Installation Operation Care Manual WM 2500SSH 4500SSH WM 6500SSH 8500SSH V Vi in no ot te em mp p I In nt te er rn na at ti io on na al l C Co or rp p w ww ww w v vi in no ot te em mp p c...

Страница 2: ...1 TABLE OF CONTENTS Important Safety Information 2 Feature Description 3 Installation Instruction 5 Use and Temperature Control 9 Care Guide 11 Troubleshooting 12 Customer Support 14 Warranty 15...

Страница 3: ...2 Important Safety Information DO NOT USE A GROUND FAULT INTERRUPTER GFI A DEDICATED 20 AMPCIRCUIT IS HIGHLY RECOMMENDED...

Страница 4: ...frigerated enclosure as far as 50 feet which will bring you extremely quiet operation The dimension and capacity are specified as follows Model Capacity Btu h 55 90 F Unit Cooler Cond Unit Electrical...

Страница 5: ...4 Evaporator Unit Condensing Unit...

Страница 6: ...nd shaded from direct sun It should not be exposed to temperatures higher than 125 F or lower than 20 F Air flow from the unit cooler should be unobstructed for at least 1 foot 2 Refrigeration Install...

Страница 7: ...te and charge system with R134A Refrigerant amount will vary depending on the length of line set 3 Air Sensor The air sensor is recommended to place in the wine room If it is in a return duct the temp...

Страница 8: ...ack white and green wires that come from the cooling unit in the electrical terminal Remove the electrical box and mount it close to the wine room so the air sensor can reach the wine room Use extra w...

Страница 9: ...8 6500SSH Electrical Wiring Diagram 8500SSH Electrical Wiring Diagram...

Страница 10: ...wine On initial start up the time required to reach the desired temperature will vary depending on the quantity of bottles temperature setting and surrounding temperature Allow 24 hours to stabilize...

Страница 11: ...s are effective beginning from the successive cycle For an immediate effect it is necessary to turn power to the UniStat off for a few seconds It is possible to choose between an electric defrost the...

Страница 12: ...need to be cleaned at least every 6 months Unplug the system or disconnect power Use a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty Plug cooling system or re...

Страница 13: ...or condenser fan f Clean condenser g Call service for removing refrigerant h Call service for OEM information 3 Fan motor running but compressor not running a Incorrect power supply b Incorrect or loo...

Страница 14: ...t wirings c Failed components a Check for proper fuse or breaker b Check for wirings and connections c Call service 8 Noisy operation a Mounting area not firm b Loose parts c Compressor overloaded due...

Страница 15: ...14 Customer Support If you still have problems please contact us at Vinotemp International 17631 South Susana Road Rancho Dominguez CA 90221 Tel 310 886 3332 Fax 310 886 3310 Email info vinotemp com...

Страница 16: ...ies express or implied including any of fitness for a particular purpose In no event shall VINOTEMP be responsible for any consequential damages what is so ever Any modification of VINOTEMP products s...

Страница 17: ...USE OF THE UNIT LOSS OF TIME OR COMMERCIAL LOSS ANY OUTER DAMAGES WHETHER INCIDENTAL CONSEQUENTIAL OR OTHERWISE THIS WARRANTY IS EXCLUSIBE AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR INPLIED...

Отзывы: