background image

                                                       

 

                       

 

- 29 -

Warranty  

 
 

Thank you for choosing a Vinotemp cooling unit. 

 
Please enter the complete model and serial numbers in the space provided: 

 
Model_________________________________________________________ 
Serial No.______________________________________________________ 

 
Attach your purchase receipt to this owner’s manual. 
 
 

1.  Limited Warranty 

         
 
VINOTEMP warrants its products, parts only, to be free from defects due to 
workmanship or materials under normal use and service for twelve months after 
the initial sale. If the product is defective due to workmanship or materials, is 
removed within twelve months of the initial sale and is returned to VINOTEMP, in 
the original shipping carton, shipping prepaid, VINOTEMP will at its option, repair 
or replace the product free of charge.  
 
This warranty constitutes the entire warranty of the VINOTEMP with respect to its 
products and is in lieu of all other warranties, express or implied, including any of 
fitness for a particular purpose. In no event shall VINOTEMP be responsible for 
any consequential damages what is so ever. Any modification of VINOTEMP 
products shall void this warranty. 
 
 

Service under Warranty 

 
This service is provided to customers within the continental UNITED STATES 
only. VINOTEMP cooling units are warranted to produce the stated number of 
BTU/H. While every effort has been made to provide accurate guidelines, 
VINOTEMP can not warranty its units to cool a particular enclosure. 
             
In case of failure, VINOTEMP cooling units must be repaired by the factory or its 
authorized agent. Repairs or modifications made by anyone else will void the 
warranty. 
             
Shall a VINOTEMP cooling unit fail, contact the dealer for instructions, do not 
return the unit to the factory without authorization from VINOTEMP. If the unit 
requires repair, re-pack it in the original shipping carton and return it to the 
factory, shipping prepaid. VINOTEMP will not accept COD shipments. If the unit 
is determined to be faulty and is within the twelve month warranty period 

Содержание Wine-Mate WM-2520SSV

Страница 1: ...co om m Rack Split Cooling System Installation Operation Care Manual WM 2520SSV WM 4520SSV WM 6520SSV w ww ww w v vi in no ot te em mp p c co om m R Re ea ad d a an nd d s sa av ve e t th he es se e...

Страница 2: ...1 Important Safety Information WARNING Do not use a ground fault interrupter GFI A dedicated 10 AMP circuit for WM 2520SSV and 15 AMP for WM 4520 6520SSV are required...

Страница 3: ...le of Contents Cellar Construction 3 Features Specifications 4 Temperature Humidity 6 Care Guide 10 User Troubleshooting 11 Installer s Instructions 14 Electrical Wirings 25 Customer Support 28 Warran...

Страница 4: ...erature surrounding the enclosure shall not exceed the temperature of the cellar by more than 25 F No cellar wall shall receive direct sun or strong wind Lighting shall be of low wattage with a timer...

Страница 5: ...cellars 50 ft so that noise and compressor vibration are isolated SSV evaporator units are designed for installation inside a rack or in a wine room corner making them an ideal choice for small and m...

Страница 6: ...eight lb Evap Unit Cond Unit WM 2520SSV WM 252SFCV WM 252SCU 18x14x12 2100 180 230 R134a 220V 50Hz 0 4A 220V 50Hz 3A 45 40 WM 4520SSV WM 452SFCV WM 452SCU 18x14x12 3700 280 900 R134a 220V 50Hz 0 4A 22...

Страница 7: ...o lock unlock the keypad SET To enter in the programming mode SET To return to the temperature display 2 Lock and unlock the keys To lock the keys press up down keys until POF is displayed to unlock t...

Страница 8: ...etting Set the temperature at 55 F for the optimum aging of wine On initial start up the time required to reach the desired temperature will vary depending on the quantity of bottles temperature setti...

Страница 9: ...lar temperature is ALU higher or ALL lower than the set point Set 2 In order to test the call function set parameters Ald 0 and dAO 0 After testing set Ald 60 and dAO 23 9 How to set low cellar temper...

Страница 10: ...elay min 1 ot probe calibration 0 US maximum set point 65 LS minimum set point 50 idF defrost cycle interval time hour 12 MdF defrost cycle endurance time min 30 ALC temperature alarm type rE relative...

Страница 11: ...lean the condenser coil regularly Coil may need to be cleaned at least every 6 months Use a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty 2 Condensate Removing...

Страница 12: ...temperature is mainly controlled by the average air temperature If the set point is 55 F with the differential 4F the cooling unit turns on at 59 F of air temperature It may be higher than 59 F if it...

Страница 13: ...st side and leave minimum 1 foot clearance for the ambient air intake side c Check for excessive size d Check for installation location e Clean condenser f Check for fan and air short circulation 8 Co...

Страница 14: ...leak No water overflow but water leak a Check for any air leak b Use drain line c Check supply air flow or air TD crossing evaporator d Clean the drip tray e Seal the leak using silicone sealant 15 Co...

Страница 15: ...building and electrical codes The condensing unit and evaporator unit are connected by a liquid line and an insulated suction line that are supplied by the installer These lines must be properly sized...

Страница 16: ...15 CAUTION Liquid and suction line locations may differ from what are shown here please check on the units for proper installation Fig 3 WM 252 652SFCV Evaporator Unit...

Страница 17: ...16 Fig 4 WM 252 452SCU Condensing Unit Fig 5 WM 652SCU Condensing Unit...

Страница 18: ...A grille can be used to cover the supply and return with 0 2 clearance or 2 3 ft long duct can be added 4 There is a gravity drain system used so the unit shall be installed level or with a slight slo...

Страница 19: ...5 ft clearance for the exhaust side and leave minimum 1 foot clearance for the ambient air intake side 4 Service valve operations 1 Process Manometer 2 Receiver Discharge or Compressor Suction 3 Liqu...

Страница 20: ...rculated 3 Air probe can be pulled out of the temperature controller around 5 ft if additional wires are needed 18 gauge wires may be used to extend the air probe 5 Checking Control Settings 1 Use of...

Страница 21: ...ntrol Head pressure setting Cut in 170 psig Cut out 120 psig Differential 50 psig It closes on rise of pressure It may need to adjust the setting in the field to avoid fan short cycle Fig 13 Condenser...

Страница 22: ...difference is more than 10 ft or the line set exceeds 75 ft use both inverted U trap and suction accumulator 3 If the condensing unit is located more than 10 ft above the evaporator unit use U trap t...

Страница 23: ...peed position then rotate the setting located on the side or front clockwise to decrease the minimum speed or counter clockwise to increase the minimum speed The minimum speed should be adjusted until...

Страница 24: ...heat and low subcooling 3 High suction pressure and high head pressure Low superheat and high subcooling 4 High to normal suction pressure and high head pressure Low subcooling 5 High suction pressure...

Страница 25: ...nd high subcooling evaporator iced 11 Evaporator restricted 12 Expansion valve restricted 13 Both evaporator and condenser restricted liquid and suction lines connected wrong 14 Liquid line restricted...

Страница 26: ...are the field wirings Use minimum 14 gauge wires for power lines If equipped with low ambient condition kit use low ambient temperature wiring diagrams A safety switch is always recommended for the co...

Страница 27: ...26 Fig 17 WM 6520SSV Electrical Wiring Diagram Fig 18 Low Ambient Temperature WM 2520 4520SSV LA Electrical Wiring Diagram...

Страница 28: ...27 Fig 19 Low Ambient Temperature WM 6520SSV LA Electrical Wiring Diagram...

Страница 29: ...8 Customer Support If you need further assistance please contact us at Vinotemp International 17631 South Susana Road Rancho Dominguez CA 90221 Tel 310 886 3332 Fax 310 886 3310 Email info vinotemp co...

Страница 30: ...ties express or implied including any of fitness for a particular purpose In no event shall VINOTEMP be responsible for any consequential damages what is so ever Any modification of VINOTEMP products...

Страница 31: ...USE OF THE UNIT LOSS OF TIME OR COMMERCIAL LOSS ANY OUTER DAMAGES WHETHER INCIDENTAL CONSEQUENTIAL OR OTHERWISE THIS WARRANTY IS EXCLUSIBE AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR INPLIED...

Отзывы: