background image

                                                       

 

                       

 

- 3 -

Feature Description 

 

  Wine-Mate split cooling system is designed and used to provide a cold 

temperature between 50~65 

°

F for a properly insulated wine room at a 

normal environment.  

  The wine room will maintain humidity of 50~70% RH even when the 

environment becomes dry and humid. 

  These temperatures and humilities are optimized for long term storage of 

wine.  

  The condensing unit can be located away from the wine cellar or other 

refrigerated enclosure as far as 50 feet, which will bring you quiet 
operation.  

  The SSD units provide two way air supply operation. The evaporator units 

can be installed on the ceiling in a cabinet or room. 

  

The dimensions and capacities are specified as follows: 
 

 

MODEL

 

EVAP UNIT 

W”xH”xD”

 

COND 

UNIT 

L”xH”xD”

 

Btu/h 

(55/90

°

F) 

CFM

 

BOTTLE 

CAPACITY 

(55/75

°

F)

 

REFRIGERANT

 

ELECTRICAL 

EVAP UNIT/ 

COND UNIT

 

WEIGHT(lb) 
EVAP UNIT/ 
COND UNIT

 

VINO-

2500SSD 

WM-25SFCD 

17.5X7.5X23 

WM-

25SCU 

18x14x12 

2500/350 

250 

cu ft 

1200 

bottles 

R134a 

115V-60HZ-1A / 

115V-60HZ-

5.7A 

35/40 

VINO-

4500SSD 

WM-45SFCD 

17.5X10.5X23 

WM-

45SCU 

18x14x12 

4500/460 

1000 
 cu ft 

4500 

bottles 

R134a 

115V-60HZ-1A / 

115V-60HZ-

6.9A 

40/60 

VINO-

6500SSD 

WM-65SFCD 

21X11.75X30 

WM-

65SCU 

24x17x18 

6500/660 

1500 
 cu ft 

6500 

bottles 

R134a 

115V-60HZ-

1.5A / 115V-

60HZ-12A 

66/90 

VINO-

8500SSD 

WM-85SFCD 

21X13.5X30 

WM-

85SCU 

24x17x18 

8500/810 

2000 
 cu ft 

8500 

bottles 

R134a 

115V-60HZ-

1.5A / 115V-

60HZ-15A 

95/115 

 

 
 
 
 
 
 
 
 
 
 
 
 

Содержание WINE-MATE VINO2500SSD

Страница 1: ...allation Operation Care Manual VINO2500SSD 4500SSD VINO6500SSD 8500SSD V Vi in no ot te em mp p I In nt te er rn na at ti io on na al l C Co or rp p w ww ww w w wi in ne em ma at te e c co om m READ A...

Страница 2: ...LE OF CONTENTS Important Safety Information 2 Feature Description 3 Installer s Instruction 6 Temperature Control Humidity Adjustment 13 Care Guide 18 User Troubleshooting 19 Customer Support 22 Warra...

Страница 3: ...2 Important Safety Information DO NOT USE A GROUND FAULT INTERRUPTER GFI A DEDICATED 20 AMP CIRCUIT IS HIGHLY RECOMMENDED...

Страница 4: ...s can be installed on the ceiling in a cabinet or room The dimensions and capacities are specified as follows MODEL EVAP UNIT W xH xD COND UNIT L xH xD Btu h 55 90 F CFM BOTTLE CAPACITY 55 75 F REFRIG...

Страница 5: ...4 Fig 1 1 WM25 85SFCD Evaporator Unit Fig 1 2 WM25 45SCU Condensing Unit...

Страница 6: ...5 Fig 1 3 WM65 85SCU Condensing Unit...

Страница 7: ...ust be properly sized for the distance between the two units After the units and the lines are installed the system must be pressure tested If no leaks are found evacuate and charge system with R134A...

Страница 8: ...uid indicator sight glass liquid line evaporator unit including liquid line solenoid valve and thermostatic expansion valve or automatic expansion valve suction line and returning to condensing unit T...

Страница 9: ...ion pressure and high head pressure High superheat and high subcooling n Low suction pressure and high head pressure High superheat and high subcooling o low to normal suction pressure and high head p...

Страница 10: ...9 7 Electrical Wiring Fig 2 2 VINO2500 4500SSD Electrical Wiring Diagram VTSTAT Fig 2 3 VINO2500 4500SSD Wiring Diagram DIGITAL CONTROLLER...

Страница 11: ...10 Fig 2 4 VINO6500SSD Electrical Wiring Diagram VTSTAT Fig 2 5 VINO6500SSD Electrical Wiring Diagram DIGITAL CONTROLLER...

Страница 12: ...11 Fig 2 6 VINO8500SSD Electrical Wiring Diagram VTSTAT UJ6220Z Fig 2 7 VINO8500SSD Wiring Diagram DIGITAL CONTROLLER UJ6220Z...

Страница 13: ...t running a Incorrect power supply b Incorrect or loose wirings c Failed components d Liquid refrigerant in the compressor e Low pressure switch shutting down the unit a Check for proper voltage b Che...

Страница 14: ...ial start up the time required to reach the desired temperature will vary depending on the quantity of bottles temperature setting and surrounding temperature Allow 24 hours to stabilize the temperatu...

Страница 15: ...conds It is possible to choose between an electric defrost the compressor is deactivated and the defrost relay is activated and a hot gas defrost both the compressor and the defrost relay are activate...

Страница 16: ...ital Controller 1 Display During normal operating conditions the display shows the value measured by the air regulation probe In case of active alarm the temperature flashes alternately to the code al...

Страница 17: ...tomatically stops as soon as the temperature returns to normal value Alarm CA with i1F PAL recovers only by switching off and on the instrument 3 Temperature Set Point 3 1 How to see the set point 1 P...

Страница 18: ...eys for 3 sec the C or F LED starts blinking 2 Release the keys then push again the Set keys for more than 7sec the Pr2 label will be displayed immediately followed from the HY parameter 3 Select the...

Страница 19: ...need to be cleaned at least every 6 months Unplug the system or disconnect power Use a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty Plug cooling system or re...

Страница 20: ...4 F the cooling unit turns on at 59 F of air temperature and turns off at 55 F of air temperature The average air temperature is 57 F and then the wine temperature is around 57 0 5 F The air is light...

Страница 21: ...ing time a Incorrect temperature setting b Incorrect voltage c Failed thermistor d Failed components e Improper condenser airflow f Dirty condenser g Overcharge of refrigerant h Discharge or suction p...

Страница 22: ...Mounting area not firm b Loose parts c Compressor overloaded due to high ambient temperatures or airflow restriction d Malfunctioning components a Add support to improve installation b Check fan blad...

Страница 23: ...22 Customer Support If you still have problems please contact us at Vinotemp International 17631 South Susana Road Rancho Dominguez CA 90221 Tel 310 886 3332 Fax 310 886 3310 Email info vinotemp com...

Страница 24: ...ies express or implied including any of fitness for a particular purpose In no event shall VINOTEMP be responsible for any consequential damages what is so ever Any modification of VINOTEMP products s...

Страница 25: ...USE OF THE UNIT LOSS OF TIME OR COMMERCIAL LOSS ANY OUTER DAMAGES WHETHER INCIDENTAL CONSEQUENTIAL OR OTHERWISE THIS WARRANTY IS EXCLUSIBE AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR INPLIED...

Отзывы: