- 17 -
2. The value of the set point will be displayed and the “°C” or “°F” LED starts
blinking;
3. To change the Set value, push the o or n arrows within 10s.
4. To memorize the new set point value, push the SET key again or wait 10s.
4) Humidity Adjustment
The parameter
Fon
is used to modulate the humidity in the wine cabinet. The
higher value of
Fon
, the higher relative humidity will be.
1. Press the
Set
+
keys for 3 sec. (the “
°C” or “°F”
LED starts blinking).
2. Release the keys, then push again the
Set
+
keys for more than 7sec, the
Pr2
label will be displayed immediately followed from the
HY
parameter.
3. Select the required parameter
Fon
by up or down keys
.
4. Press the “
SET
” key to display its value.
5. Use up or down keys
to change its value.
6. The default value is 0, change high or low value to maintain high or low
humidity.
7. Press “
SET
” to store the new value.
8.
To exit
: Press
SET +
or wait 15sec without pressing a key.
5) Manual Defrost
Push the DEF key for more than 2 seconds and a manual defrost will start.