background image

7 

 

 

1 7 6 2 1   S o u t h   S u s a n a   R o a d ,   R a n c h o   D o m i n g u e z ,   C a l i f o r n i a   9 0 2 2 1  

i n f o @ v i n o t e m p . c o m  

 

 

previously removed from). 

7.

 

Carefully  slide  the  fridge  door  back  on  to  the  top  hinge,  making  sure  it’s  the 
right way up. Screw the bottom hinge into place on the new side. 

8.

 

Check that door is aligned horizontally and vertically and that the seals are 
closed on all sides before finally tightening the bottom hinge. Re-adjust the 
leveling feet as needed. 

9.

 

If cooler has been on its side or tilted, always wait several hours before 
reconnecting to power source to allow the refrigerants to settle. 

 

Installing the Castors 

z

 

Remove the 4 castors from one of the boxes inside the unit. Install the two castors 
with metal bracket at the front designated positions of the cabinet base and the 
additional two castors at the rear-designated positions (Four screw holes are pre-
supplied). 

                           

 
 

 
 

 
 
 
 
 
 
 

z

 

In order to release or lock the brake, follow the below guide. 

          

Step d own  to  Br ake 

Step on  to Release  Brake

 

 
Kegerator Assembly 

 

Place the gasket over the hole opening on 

the worktop. 

 

Pass both the wing nut and the beer tube 

through the hole on the worktop until the 
beer tap is resting on top of the cabinet. 

 

Revolve the beer tap clockwise and secure it. 

 

Spanner faucet wrench provided for either 

removing or tightening connection.  

 

Attach the black plastic lever (pull handle) 

provided on the top of the faucet tightening 
it by hand clockwise until the end, holding i

the silver snug underneath so it does not 
move. (See Figure 1)

 

Содержание VT - PONYKEG

Страница 1: ...A P R O U D H E R I T A G E O F E X P E R I E N C E Q U A L I T Y P o n y S i z e K e g e r a t o r V T P O N Y K E G O W N E R S M A N U A L W W W V I N O T E M P C O M ...

Страница 2: ...ATIONS 17 TERMS OF SALE AND WARRANTY 18 GENERAL OPERATING INSTRUCTIONS Remove all external and internal packaging from your appliance Be sure that all parts have been included before discarding any packaging materials You may want to keep the box and packing materials for use at a later date Upon receipt and inspection of unit the supply cord must be replaced if it is damaged Contact our customer ...

Страница 3: ...ning agents or abrasives on the interior These cleaners may damage or discolor the interior Do not operate with housing panels removed Intended for household use When disposing of refrigerated appliances special handling is often required It is the consumer s responsibility to comply with federal and local regulations when disposing of this product To ensure proper ventilation for your appliance t...

Страница 4: ...he unit and not left exposed or dangling to prevent accidental injury z The unit should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating label on the appliance This provides the best performance and also prevent overloading house wiring circuits that could cause a fire hazard from overheated z Never unplug the unit by pulling the power ...

Страница 5: ...nder 14 Castors 4 Note If unit has been placed in a horizontal or tilted position for any period of time wait 2 hours before connecting to power For your safety CO2 Gas Cylinders are shipped empty Most locations which sell kegs will either be able to fill your cylinder or direct you to another nearby location to do so 1 7 6 2 1 S o u t h S u s a n a R o a d R a n c h o D o m i n g u e z C a l i f ...

Страница 6: ...iator etc Direct sunlight may affect the acrylic coating and heat sources may increase electrical consumption Extreme cold ambient temperatures may also cause the beer dispenser not to perform properly This unit is not designed for outdoor installation i e garages porches etc Avoid locating the Beer Dispenser in moist areas Plug the beer dispenser into an exclusive properly installed grounded wall...

Страница 7: ...astors from one of the boxes inside the unit Install the two castors with metal bracket at the front designated positions of the cabinet base and the additional two castors at the rear designated positions Four screw holes are pre supplied z In order to release or lock the brake follow the below guide Stepd own to B r ake Step on to Release Brake Kegerator Assembly Place the gasket over the hole o...

Страница 8: ... cylinder in a way that you would be able to read the numbers on the gauges and easily access shut off valves WARNING CO2 gas can be dangerous CO2 cylinders contain high pressure compressed gas which can be hazardous if not handled properly Make sure you READ and UNDERSTAND the following procedures for CO2 cylinders BEFORE INSTALLATION 1 ALWAYS connect the CO2 cylinder to a regulator Failure to do...

Страница 9: ...lled when the keg is in place to protect against unnecessary damage to the floor of the cabinet liner Installation of the Beer Keg Position the beer keg directly in front of the open door Using keg handles only carefully lift the beer keg See Figure 4 To place the beer keg inside the cabinet brace your knees behind the beer keg Lift the front of the keg just enough so the front edge of the keg is ...

Страница 10: ...ustment lock nut marked 2 2 Using a flat screwdriver turn regulator screw marked 3 If increased low pressure is sought rotate screw clockwise By rotating it counter clockwise low pressure will be decreased When required operating pressure is attained retighten lock nut 2 3 Open secondary shut off valve to let CO2 flow into the keg Figure 8 Figure 9 Figure 10 DISPENSING BEER Keep beer keg refrigera...

Страница 11: ... All Refrigerator configuration please follow below e control knob to the OFF position 2 3 Close the secondary shut off valve on the regulator pipe 4 Close the connection between the beer keg a 5 Drain any remaining beer from the lines 6 Disconnect the beer line and CO2 air line from the keg cou 7 Remove the beer keg and bottom metal plate 8 Remove the keg coupler 9 Disconnect the air line from th...

Страница 12: ...cure in an upright position during transportation item Cleaning Your Beer Dispenser ure control to OFF unplug the beer dispens Wash the inside surfaces with should be about 2 tablespoons of baking soda to a quart of water Wash the s Wring excess water out of the sponge or cloth when cleaning area of the controls or any electrical parts Wash the outside cabinet with warm water and mild liquid deter...

Страница 13: ...corrugate metal 2 Improper drawing of beer into glass ucet when drawing When done properly and the Open faucet quickly and completely Check and find the correct distance to hold glass from fa foam should be a tight creamy head collar on the average glass should be to 1 high Beer drawn without head has appearance of being flat 3 Over chilling cooler or beer system ive low temperatures may cause haz...

Страница 14: ...aphragm may require replacing 10 Moisture in air system With the use of an air compressor it is imperative to have a moisture trap installed in the pre cooler and drained daily This is in addition to an activated charcoal filter necessary to purify the air just before it enters the barrel With tank type compressors drain the tank weekly Moisture traps should be drained daily 11 Drafts Rapid air mo...

Страница 15: ...emperatures may cause the start of secondary fermentation in the barrel Problem Wild Beer When poured beer is all foam or has too much foam and not enough liquid beer Causes Corrections 1 Improper drawing beer into glass Open faucet quickly and completely Check and find the correct distance to hold glass from faucet when drawing Proper foam should be a tight creamy head and the collar on the avera...

Страница 16: ...ossible however remembering that the applied pressure must be slightly higher than the internal pressure of the beer no more than 18 lbs should be applied The colder the beer and the higher the applied CO2 pressure the more rapid the absorption of CO2 by the beer This over carbonates the beer causing Wild Beer 9 Not enough pressure Make sure pressure is on Always turn pressure on before drawing be...

Страница 17: ...correctly Door gasket does not seal properly Beer dispenser does not have the correct clearances Vibrations Check to assure that the beer dispenser is leveled Beer Dispenser seems to make too much noise Rattling noise may come from the flow of the refrigerant this is normal As each cycle ends you may hear gurgling sounds caused by the flow of refrigerant in your beer dispenser Contraction and expa...

Страница 18: ...n of unit is not included in warranty For a scratch and dent or refurbished unit warranty is 3 months from your dated invoice parts for function only not cosmetic There is no warranty on parts purchased separately Purchaser s exclusive remedy is limited at Seller s option to repair or replace defective part s with either new or factory reconditioned part s Purchaser is responsible for shipping the...

Страница 19: ...19 1 7 6 2 1 S o u t h S u s a n a R o a d R a n c h o D o m i n g u e z C a l i f o r n i a 9 0 2 2 1 i n f o v i n o t e m p c o m ...

Страница 20: ...se do not place the unit within reach of children For adult use only Contact info vinotemp com with any questions or visit www vinotemp com 17621 S Susana Road Rancho Dominguez CA 90221 www vinotemp com Vinotemp is a registered trademark of Vinotemp International All products features and services are subject to change without notice We cannot guarantee the accuracy of the contents of this documen...

Отзывы: