Not cooling but
compressor
running
a) Bad evaporator air flow
b) Bad evaporator fan
c) Refrigerant leakage
d) Refrigeration system restriction
a) Check for restrictions
b) Check for fan turning
c) Call service regarding loss of
refrigerant
d) Call service to check restrictions
Evaporator
freezing up
a) Bad evaporator air flow
b) Bad evaporator fan
c) Not stopping due to air leak,
high ambient temperature or low
setting
d) Low ambient temperature
e) Bad thermistor
f) Moisture in the system, working
initially then stopping
g) Refrigerant low or leaking
h) Capillary tube blockage
a) Check for restrictions
b) Check if fan is turning
c) Check for seal, door opening, ambient
temperature and setting
d) Defrost unit
e) Check thermistor resistance
f) Call service to check sealed system
g) Call service to check amps and sealed
system
h) Call service to check low side
pressure
Water leak
a) Air leak in the cabinet
b) Bad evaporator air flow
c) Water passages restricted
d) Drip tray leak
a) Check for air leak
b) Check for air restrictions
c) Clean the drip tray
d) Check the drip tray
House circuit
tripping
a) Incorrect fuse or breaker
b) Incorrect wiring
c) Failed components
a) Check fuse or breaker
b) Check wiring and connections
c) Call service
Noisy operation
a) Mounting area not firm
b) Loose parts
c) Compressor overloaded due to
high ambient temperature and
bad ventilation
d) Malfunctioning components
a) Add support to improve installation
b) Check for loose washers, screws and
tubing.
c) Check ambient temperature and
ventilation
d) Call service to check loose,
inadequate internal lubrication or
incorrect wiring