without pressing any key, the key lock will be activated automatically. To remove the lock, press
the
UP
and
DOWN
keys at the same time for at least 5 seconds and the indicator light will flash
three times to confirm the input.
ºF/ºC
Selector
Select the temperature display setting in Fahrenheit or Celsius degree. To change the
temperature from Fahrenheit to Celsius or from Celsius to Fahrenheit, press and hold the
LIGHT
key for 5 seconds.
4.1.4 CONTROL OF FANS
Fan F1C & F1H
:
For single zone models, F1C & F1H are the evaporator fan motors positioned in the
cabinet inside. For dual zone models, F1C & F1H are the fan motors positioned in the
upper zone. For three zone models, F1C & F1H are the fan motors positioned in the
middle zone.
When the set temperature of upper zone is lower than the storage temperature, Fan 1C &
F1H will operate. At the rest time Fan F1C & F1H will cycle on 20 seconds and off 30
seconds to circulate air inside the cabinet.
For single zone models with heating function, Fan 1C & F1H will operate when the heater
is ON.
Fan F2C
:
Only available in the models of dual zone or three zone. For dual zone model, F2C is the
fan motor positioned in the middle divider. For three zone models, F2C is the fan motor
positioned in the bottom divider.
When the set temperature of the lower zone is lower than the storage temperature, Fan
F2C will operate.
When the set temperature of upper zone for dual zone or middle zone for three zone is
higher than the storage temperature, Fan F2C will operate.
At the rest time Fan F2C will be OFF.
Fan F2H
:
Only available in the models of dual zone or three zone. For dual zone model, F2H is the
fan motor positioned in the bottom zone. For three zone models, F2C is the fan motor
positioned in the bottom zone.
When the set temperature of lower zone is higher than the storage temperature, Fan F2H
will operate. At the rest time Fan F2H will cycle on 20 seconds and off 30 seconds to
circulate air inside the cabinet.
Fan F3C
:
Only available in the models of three zone. F3C is the fan motor positioned in the top
divider.
When the set temperature of the top zone is lower than the storage temperature, Fan
F3C will operate.
At the rest time Fan F3C will be OFF.
Fan F3H
:
Only available in the models of three zone. F3H is the fan motor positioned in the top
zone.
When the set temperature of the top zone is higher than the storage temperature, Fan
F3H will operate. At the rest time Fan F3H will cycle on 20 seconds and off 30 seconds to
circulate air inside the cabinet.
Fan F0
:
Only available in built-in models. When the compressor is ON, Fan F0 will be ON. At the
rest time Fan F0 will be OFF.