45
ACM Family - System Installation & Configuration
A100K10647
IP Flush Master as PA panel
Audio volume adjustment
Handling of feedback
A roa ast o re- efine messages
7.7.2
Configure audio interface from SPA-V2 to ACM
The audio interface from the SPA system is connected to the ACM
program input. The ACM remote control input RCI 1 is triggered by the
SPA system to make it so that audio from SPA is played either as a GA
announcement or emergency PA announcement.
Select program
Click the
Audio Programs
icon
Sele t t e au io rogram in ut to e use rom t e list normally
Program 5
Click
Change
Check the
Program Over Conversation
and
Volume/Handset
Override
boxes
Click
OK
Set the RCI 1 event in station 5000
o e a le to rogram all eatures a ummy num er as to e ma e
in the exchange and the event connected to this number since an RCI
string can only contain up to 40 characters.
The following RCI programming will trigger an event type 15 (
Event
Trigger Feature
in t e e ent an ler
ere station
ysi al no
400) is the event owner and directory number 5001 is the “Related to”
number.
The actual commands to be executed are programmed in the event
handler.
Click the
Exchange & System
icon
Click
RCI
Select
Input 1
(RCI 1) to be used to signal audio from SPA
Click
Change
In the
ON
Action
fiel enter
$ER U15 U0 U1 U1 L5000 U3 L5001
Triggers event type 15, subevent 0, When Change To = ON, Owner
= station 5000, Related To = directory number 5001
In the
OFF
Action
fiel enter
$ER U15 U0 U0 U1 L5000 U3 L5001
Triggers event type 15, subevent 0, When Change To = OFF, Owner
= station 5000, Related To = directory number 5001
Check the
Normal Open
box
Leave
Delay Before ON Action
at
0.0
sec.
nter a es ri ti e te t e g
Signal audio from SPA
Click
OK
Set the ON event
This programming will disable feature no. 5 -
Audio program selection
rom lass o ser i e or grou no
It ill not e ossi le
to dial C or 800 to these groups in order to prevent PA audio on the
intercom station. An audio connection will be set up from input no. 5 to