A100K 10430 v.1.0
ACM Telephone System – AMC-M-A
Page 19
5.1.1 Connect to AlphaWeb
z
Connect the PC Ethernet port to the LAN port (Eth0) on the ACM-E7
backplane.
z
Use your web-browser to connect to the AlphaWeb.
Enter
http://169.254.1.5
(default address) in the address field
1
Connection with the ACM is verified by the text:
z
[
Login
] Secure AlphaWeb (https)
[
Login
] Unsecure AlphaWeb (http)
z
Click on [
Login
] for unsecure (http) unless encrypted access to
internet is required for safety reasons
z
User is prompted for user name and password
Default user name:
alpha
Default password:
com
This login will give reading rights only.
z
To be able to change the configuration, the user must log in as an
administrator. The default login will then be:
User name:
admin
Password:
alphaadmin
A window with the exchange configuration is shown.
5.1.2 Save and apply changes
When new configuration parameters are entered, they should be saved
to the configuration file by pressing the
Save
button.
The configuration data is then saved to the AlphaCom configuration file
only, and not applied to the running configuration. To get the new
configuration data applied to the running configuration, press the
Apply
button.
1
The PC must be assigned to an IP address and network mask to the same network as the AlphaCom. If the PC is set to ‘Obtain IP
address automatic’, this will happen automatically after 1 minute (Windows Automatic Private Address).
Figure 14 Connect the PC to
Eth0
Figure 15 AlphaWeb Login
window
Figure 16 Exchange configuration
Et
h
0
Et
h
1
Se
ri
a
l P
o
rt
0
Ser
ial Po
rt
1
US
B
485
422
Eth0