background image

VPSU-24 

Series 

Installation 

Instructions 

     VPSU-24/IS-Iss1 

281111 

4

 

 

Battery Protection 

 
The batteries and electronic circuitry are protected against reverse polarity 
connection by a self-resetting electronic fuse. 
 

Maintenance 

 
This unit is to be used by service personnel only; there are no user serviceable 
parts.  No maintenance is required other than routine periodic testing and 
replacement of the standby batteries.   
 

Please note that high voltage is present under the cage – handle with care.  
Do NOT touch.  Do NOT remove the cage. 

 
For further information on routine battery replacement, please contact your battery 
supplier or manufacturer. 
 

Specifications 

 

Power supply 

Type A, Ungraded, Environmental 
Class 2 

AC Input voltage 

230v +10% -15%, 50Hz ± 15% 

AC Input fuse 

- VPSU-24-01A 

 

- VPSU-24-02A, 

VPSU-24-02B/1 

- VPSU-24-03A, 

VPSU-24-03B/1 

20mm anti-surge fuse rated at: 

- 230V, 

1A 

- 230V, 

2A 

- 230V, 

3A 

Output voltage 

24v nominal 

Output ripple 

Less than 100mV  

Battery recharge time 

Less than 72 hours 

Operating temperate range 

-10°C to +40°C 

 

Product Part Numbers 

 
 

A Box 

B Box 

1 Amp – general purpose 

VPSU-24-01A On 

request 

2 Amp – general purpose 

VPSU-24-02A On 

request 

3 Amp – general purpose  

VPSU-24-03A On 

request 

2 Amp – with battery charging 

On request 

VPSU-24-02B/1 

3 Amp – with battery charging 

On request 

VPSU-24-03B/1 

 
Sizes and Weights 

 
 

PCB 

“A” Housing 

“B” Housing 

Size (H x W x D mm) 

130 x 100 x 38 

235 x 170 x 85 

260 x 320 x 87 

Weight (kg) 

0.19 

2.0 

3.2 

 

Содержание VPSU-24-01a

Страница 1: ...A 1A 24 volts VPSU 24 02A 2A 24 volts VPSU 24 03A 3A 24 volts VPSU 24 02B 1 2A 24 volts with battery charging VPSU 24 03B 1 3A 24 volts with battery charging Vimpex Ltd Tel 44 0 1702 216999 Fax 44 0 1702 216699 Star Lane Great Wakering Essex SS3 0PJ UK www vimpex co uk sales vimpex co uk ...

Страница 2: ...nals to an un switched fused spur Connect the tamper outputs to the control panel as appropriate see control panel manual for details Connect the 24v power output to the system Fit the battery connectors where appropriate VPSU 24 02B 1 and VPSU 24 03B 1 only Switch on the AC supply and confirm that the ON LED is lit LAYOUT VPSU 24 01A VPSU 24 02A VPSU 24 03A ...

Страница 3: ...rth is connected to the metal enclosure Tamper Output This voltage free output is connected to the Tamper Switch These terminals will be shorted when the tamper switch is closed 24V Power Output Terminal blocks are provided to connect to the system The ON LED indicates that 24V is available from these terminal blocks Auxiliary Power Supply Batteries These power supplies are compatible with 7AH or ...

Страница 4: ...ery supplier or manufacturer Specifications Power supply Type A Ungraded Environmental Class 2 AC Input voltage 230v 10 15 50Hz 15 AC Input fuse VPSU 24 01A VPSU 24 02A VPSU 24 02B 1 VPSU 24 03A VPSU 24 03B 1 20mm anti surge fuse rated at 230V 1A 230V 2A 230V 3A Output voltage 24v nominal Output ripple Less than 100mV Battery recharge time Less than 72 hours Operating temperate range 10 C to 40 C ...

Отзывы: