shading solutions by

VIMCO

TM

All MDU’s with the same room
address       

and

the

same        address

Multiple MDU Set-Up Codes

SETTING UP MOTOR DRIVE UNIT (MDU) - MULTIPLE MDU's

Control Station:

Determines which MDU's in the system will respond to a "Group" keypad or "Group" interface control

that is wired to the MDU being setup. It is not necessary to change the control station setting of an MDU that does not have
any keypads or interfaces wired to it.  

Room Address:

The room address groups MDU's on the communication link. A group is defined as all MDU's with the

same room address number. There are 32 room addresses available in a single system, therefore, a system can have up to
32 groups. Typically, all MDU's in a room will be set to the same room address. Use the room address to help determine
how keypads will control the MDU's in the system.  Refer to the control station setting table below for information on how
the room address setting affects how the system is controlled by keypads or interfaces.

Scene Lockout:  

Turns off the ability to set or adjust PRESET stop points. To activate, set the scene lockout setting to 1.

To deactivate, set the scene lockout setting to 0. Changing this setting on any MDU will change all the MDU's in the
system.  Scene lockout setting can be deactivated from any MDU in the system.

Link Address:

Each MDU must be set to a unique Link Address number to allow the MDU's to communicate on the

communication link. There are 64 link addresses available, meaning the maximum number of MDU's in a single system is
64.

Any keypad or interface 

CANNOT

be wired to more

than one MDU.

Group keypads/interfaces and individual
keypads/interfaces can be wired to the same MDU.
A maximum of 9 keypads/interfaces can be wired
to one MDU.

There are two types of 

Sivoia

®

keypads and

interfaces, 

group

and

individual

types. The table

to the left describes how a group type controls a
system depending on the 

CS

setting of the MDU it

is wired to. An individual type only controls the
MDU it is wired to, regardless of the 

CS

setting of

the MDU it is wired to.

SPECIAL NOTES:

Control Station Setting Table

MDU

CS

Setting

0

1

2

Which MDU’s in a System Will

Respond

All MDU’s with the same room
address

All MDU’s in the system

All MDU’s with the same room
address         

and

the same Front (F)

or Rear (r) assignment in the
address 

4

3

5

All MDU’s with the same room 
address        

and

the same number (1,

2, 3, or 4) in the         address setting 

All Front MDU’s or all Rear MDU’s
in the system

What MDU Address Settings

Determine which MDU in the

System Will Respond 

Room address

Room address
IR address

Not dependent on       and
address settings

Room address
Front or Rear in the IR address

Room address
Same number (1, 2, 3, or 4) in the
IR address

Front or Rear in the
IR address

IR Address: 

Used to set the IR address a MDU will respond to.  Some IR hand controls have the ability to control

subgroups of shades within a group, as defined by the room address described above. There are 16 subgroups available.
Each IR address (subgroup) is made up of two parts, the IR address number (1, 2, 3, 4, 5, 6, 7 or 8) and its shade location
(F or r), the FRONT shade or the REAR shade. Any number of MDU's can have the same IR address. The IR address can
also be used to determine subgroups of the MDU's when a keypad or interface is used to control the system. Refer to the
control station setting table below for information on how the IR address affects how the system is controlled by keypads or
interfaces. 

6

Содержание LUTRON Sivoia SV-MDU-HT-W-L

Страница 1: ...r Module A Typical Sivoia Motorized Shade System Wallstation Controls SV IR Infrared Receiver Module and Infrared Handheld Transmitter not included with this kit IMPORTANT NOTES These instructions app...

Страница 2: ...High Torque Axle MDU Idler Support Mounting Brackets right mount equipment shown 1 2 in 13 mm Idler and MDU Truss head Screws x8 2 1 2 in 64 mm Hex Head Self Drilling Screws x12 2 Phillips Screwdrive...

Страница 3: ...32 F 122 F 0 C 50 C 2 Depending on the height of the shade tube width can be up to 1 4 in 6 4 mm wider than the specified Fabric Width FW 3 Measure Tube Length see diagram below and use this dimensio...

Страница 4: ...s to studs in the wall using no less than six 6 hex head self drilling screws Note All six 6 screws must be securely fastened to a stud or other structural member CAUTION Sivoia High Torque Roller Sha...

Страница 5: ...s hexagonal drive ball You may need to rotate the roller in order to push the shade over the hexagonal drive ball C Insert the idler pin into the slot of the idler support and drop it into place Make...

Страница 6: ...e idler support is considered to be in the locked position when the idler pin cannot be removed from the idler support slot see diagram below Idler Support Locked Shade Retaining Leveling Screw CAUTIO...

Страница 7: ...ect wires to the terminal block according to the diagram below D Replace the terminal block and the terminal block cover Wire to a Sivoia plug in transformer junction box mount transformer or a Sivoia...

Страница 8: ...nal Blocks Control Comm Link Comm Link Power Supply Control Next MDU Next MDU Comm Link Power Supply Wire Type Control Description 2 conductors 22 24 AWG 3 conductors 2 shielded 1 drain 24 AWG Belden...

Страница 9: ...the Close Limit The display will read and blink for 4 seconds then go blank SET OPEN CLOSE MODE Open Limit The position the shade moves to when it opens Close Limit The position the shade moves to wh...

Страница 10: ...individual keypads interfaces can be wired to the same MDU A maximum of 9 keypads interfaces can be wired to one MDU There are two types of Sivoia keypads and interfaces group and individual types The...

Страница 11: ...ely 4 seconds until appears in the MDU s LED display OPEN PRESET CLOSE PRESS ONCE Shade goes to open limit PRESS ONCE Shade goes to close limit PRESS To close shade PRESS To open shade PRESS ONCE Shad...

Страница 12: ...to five 5 SV IR EXT 10 extension cables 10 ft 3 m each Note To control an individual shade with an IR transmitter the SV IR must be connected to that MDU If there is a Group Subgroup of MDU s with th...

Страница 13: ...ar may be binding on the roller frame or end brackets Check for and clear all obstructions The shade does not respond to control 1 Check that power is connected to the shade 2 Check that the wall keyp...

Страница 14: ...02 mm 7 95 202 mm 5 4 137 mm 5 127 mm 3 4 87 mm 4 25 108 mm MDU Mounting Bracket Idler Mounting Bracket MDU Dimensions Side View A Side View B Front View Front View Side View Front View Side View Back...

Страница 15: ...Page 15 shading solutions byVIMCOTM Notes...

Страница 16: ...ents and equipment external to the SIVOIA Motorized Window Shade System such as a Non Lutron lighting and automation systems b Building wiring and c Other manufacturers equipment including but not lim...

Отзывы: