Interface module
41030UP
Terminal functions
CA-
Input programmable using configuration
software (e.g. lock release command, door
open signal sensor, command of actuator
available in system). Note: connect to an
isolated SELV voltage free-contact.
CA+
Terminal functions
OUT1
NO Relay output with NO and NC contacts cho
-
sen by the installer.
The contact can control resistive loads exter-
nally powered with maximum current 1 A and
maximum voltage 48 Vdc (maximum voltage
permitted by EN 62368-1 for the ES1/SELV).
C
NC
OUT2
NO Relay output with NO and NC contacts cho
-
sen by the installer.
The contact can control resistive loads exter-
nally powered with maximum current 1 A and
maximum voltage 48 Vdc (maximum voltage
permitted by EN 62368-1 for the ES1/SELV).
C
NC
Terminal functions
B2 Due Fili Bus
B1
E+ Additional external power supply, from power supply unit
6923 (U).
E-
CA+ Lock control additional button (Default).
Alternatively (if configured via SaveProg), sensor input
to signal “Door Open”.
CA-
S+
Electric lock output
Note
: S+/S- outputs. The entrance panel supplies a
current peak IT>1A for 10ms after which there follows a
maintenance current IM=200mA for the entire duration of
the lock command (see lock time).
S-
Display
41018UP
Alphanumeric
keyboard
41019UP
Terminal block for connection to display
Terminal block for connection to keyboard
40425 audio entrance panel rear view
M
Video signal input for external CCTV camera
(V= coaxial core, M=earth)
V
Outdoor video camera connection terminal block
(only for 40425)
Due Fili Plus
41002UP audio
unit
Morsettiera di collegamento alla unità audio/video
7
EN
PIXEL UP: 40405 - 40425