Description

Type 692D is a passive floor distributor. The distributor can be housed inside 

a junction box or on DIN rail. The SI632 wiring diagram refers to a video door 

entry installation with one cable riser and floor distributor. Other configurations 

can be found in the instructions supplied with the entrance panels or electronic 

units or in the Two-Wire manual.

Characteristics

The maximum current for each output is 700mA (can support simultaneous ac-

tivation of two monitors in parallel). 

Operating tempe 5 / + 40 °C. 

Dimensions (Width x Height x Depth): 60x82x21 mm

Legend: terminals and connections

IN

Two-Wire cable riser input.

OUT

Two-Wire cable riser output.

1A - 1B 

Output to interphone/monitor. Must always be used (connected).

2A - 2B 

Output to interphone/monitor. If not connected see description of T2. 

3A - 3B 

Output to interphone/monitor. If not connected see description of T3.

4A - 4B 

Output to interphone/monitor. If not connected see description of T4.

TOUT 

3-pole pin-strip. The jumper must be removed if the cable riser continues to the OUT terminal. It must be inserted 

on 100 (default) or 50 if the 692D is the last distributor in the chain. 

T2 

2-pole pin-strip. With interphone or monitor connected to terminals 2A and 2B, the jumper must be removed. If 

nothing is connected on the terminals, leave the jumper inserted. 

T3 

2-pole pin-strip. With interphone or monitor connected to terminals 3A and 3B, the jumper must be removed. If 

nothing is connected on the terminals, leave the jumper inserted. 

T4 

2-pole pin-strip. With interphone or monitor connected to terminals 4A and 4B, the jumper must be removed. If 

nothing is connected on the terminals, leave the jumper inserted.

Connections and settings

Connection of output 1A and 1B is necessary for the installation to function correctly. 

If lines 2A - 2B, 3A - 3B, 4A - 4B are connected, then it is necessary to remove jumpers T2,T3, T4 respectively. If they are not used, leave 

jumpers T2, T3, T4 inserted. If the cable riser continues to the OUT terminal, remove the TOUT jumper. On the last 692D connected to the 

riser (OUT terminal is not used), the TOUT jumper must be inserted on 100 if using Elvox cable, or 50 if using CAT5 twisted pair cable.

Area serigrafia

Serigrafia

Risultato finale

EN

Содержание ELVOX 692D

Страница 1: ...nstrucciones instalador Manual do instalador Art 692D Distributore video passivo al piano Passive video distributor on landing Distributeur vid o passif palier Passiver Video Etagenverteiler Distribui...

Страница 2: ...in strip a 3 vie Il Jump va tolto se al morsetto OUT il montante continua Deve essere inserito su 100 default o 50 se il 692D l ultimo della catena T2 Pin strip a 2 vie Con citofono o videocitofono co...

Страница 3: ...he jumper must be removed if the cable riser continues to the OUT terminal It must be inserted on 100 default or 50 if the 692D is the last distributor in the chain T2 2 pole pin strip With interphone...

Страница 4: ...UT Pin strip 3 voies Le cavalier doit tre enlev si le montant continue la borne OUT Il doit tre ins r sur 100 par d faut ou sur 50 si l art 692D est le dernier de la cha ne T2 Pin strip 2 voies Avec p...

Страница 5: ...teigleitung an der Klemme OUT weitergef hrt wird Er muss an 100 Default bzw an 50 eingesetzt werden wenn der Verteiler Art 692D der letzte in der Kette ist T2 Kontaktleiste 2 polig Mit an den Klemmen...

Страница 6: ...cripci n de T4 TOUT Pin strip de 3 v as El puente debe retirarse si el montante sigue despu s del borne OUT Debe conectarse a 100 por defecto o 50 si el 692D es el ltimo de la cadena T2 Pin strip de 2...

Страница 7: ...ligado consulte a descri o de T4 TOUT Pin strip de 3 vias O Jumper deve ser retirado se a coluna montante continuar no borne OUT Deve ser inserido em 100 por defeito ou 50 se o 692D for o ltimo da cad...

Страница 8: ...e installati il pi vicino possibile al dispositivo a cui vengono collegati Additional power supply units type 6923 6582 6982 must be installed as near as possible to the device to which they are conne...

Страница 9: ...Art 6329 6329 C B6 Monitor serie Tab Art 7529 7529 D B8 Monitor serie 5700 Art 5721 G Alimentador suplementario Art 6923 K Tecla de llamada desde fuera de la puerta N Distribuidor v deo pasivo en pla...

Страница 10: ...sizionato su B per cavo Elvox o su C per cavo CAT5 con doppini ac coppiati SE E SOLO SE il BUS termina sul dispositivo stesso Va lasciato su A se si effettua l entra esci utiliz zando i morsetti 1 2 d...

Страница 11: ...LISA TEURS CONFORM MENT LA DIRECTIVE 2002 96 RAEE Pour prot ger l environnement et la sant des personnes et viter toute sanction administrative l appareil portant ce symbole ne devra pas tre limin ave...

Страница 12: ...Vimar SpA Viale Vicenza 14 36063 Marostica VI Italy Tel 39 0424 488 600 Fax Italia 0424 488 188 Fax Export 0424 488 709 www vimar com S6I 692 D00 04 1501 VIMAR Marostica Italy...

Отзывы: