Number of call digits (*)
Used to select the mode and if required the maximum number of digits used to call an indoor station.
• Natural: up to 3 digits for vertical system, up to 5 digits for horizontal system, remapping not active.
• 4 digits: up to 4 digits, remapping active.
• 8 digits: up to 8 digits, remapping active.
External Video (only with 41002)
Used to enable the optional video input for an analogue video camera. Audio/video calls can therefore be made.
Voice Synthesis
This option is used to enable/disable voice synthesis on the outdoor station.
3.3.1.6. Info
This section gives the release information for the devices installed on the outdoor station and, in the case of Due Fili Plus systems,
also the type of installation (vertical or horizontal) and the ID of the entrance panel the display is connected to.
Av fw ver = audio video module version
(*)
lcd fw ver = display module version
Kp. fw ver = keypad version
Rfid fw ver = RFID module fw version
Fp fw ver = Fingerprint module fw version
(*)
3.3.1.7. System
This section lets you restore the factory settings of the various devices or restart the outdoor station.
• Reset Settings: OK/Delete
Restores the factory default settings of the display module, after confirmation.
The values restored are: Language, Colour, Home Page, Font, Brightness, Standby and the Administrator/Installer Passwords.
• Reset Out. St.: OK/Delete
(*)
Restores the factory default settings of the outdoor station, after confirmation.
• Restart Out. St.: OK/Delete
Restarts the outdoor station.
• Restart System: OK/Delete
(*)
Restarts the entire Due Fili system.
After the restart, the display shows the screen described in paragraph 3.5.6.
• External memory reset: OK/Delete
(*)
Confirming the external memory reset deletes any names in the Contacts List, access codes and push button remapping,
Actuators, Access tags and Logos.
3.3.1.8. PASSWORD
This section is used to change the passwords associated to the installer and/or administrator to access the settings menu. To validate
the password change, enter the new password twice consecutively.
(*)
Only for Due Fili Plus installations
35
EN
41018