background image

Viale Vicenza 14

36063 Marostica VI - Italy

www.vimar.com

20593  02  2110

EIKON

20593

ARKE

'

19593

IDEA

16493

PLANA

14593

Connected actuator 

The actuator is equipped with a relay output with a current meter and a front push button with 
which to reset the load and perform configuration/reset. Its function is to protect against overcur-
rent by cutting off the load when the threshold value set via the View Wireless App is exceeded; 
the load cut-off is signalled via the red flashing of the LED situated on the front of the device. Load 
reactivation, aside from the front push button, can also be done via the View App. The View App 
also makes it possible to view the instant power consumed. 

TWO OPERATING MODES (ALTERNATIVE)

 

 

or

 

Download the View Wireless 

 App from the stores onto the tablet/smartphone you 

will be using for configuration.

When the device is powered for the first configuration, we recommend you search for any 
new firmware and perform the update.
Depending on the mode you select, you will need:  

   

  

Gateway

art. 20597-19597-16497-14597 

Zigbee Gateway 

(Amazon Echo Plus, Echo Show or Echo 

Studio) 

Alexa App

View App 

 

for management via smartphone/tablet 

Alexa, Google Assistant, Siri and Homekit 

voice assistants for possible voice oper-

ation  

 

CONFIGURATION IN 

1.

 Create your Installer account on MyVimar (on-line).

2.

 Wire all the devices in the system (2-way switches, actuators, thermostats, gateway, etc.). 

3.

 Start the View Wireless App and log in with the credentials you just created.

4.

 Create the system and the environments.

5.

 Associate all the devices with the environments, except for the gateway (which should be 

associated last).

To associate the actuator:
• Select “Add” ( 

 ), choose the environment to place it and give it a name

• Select 

 ; activate the Bluetooth connection on your tablet/smartphone and approach 

the actuator

• Press the front push button and set the desired function 

6. 

 For every device, set the function, the parameters and any accessory devices (wired or radio 

control and related function).  

7.

 Transfer the configuration of the devices to the gateway and connect it to the Wi-Fi network.

8.

 Transfer the system to the Administrator user (who must have created his/her profile on 

MyVimar).

For full details, see the View Wireless App manual that can be downloaded from the www.

vimar.com website.

CONFIGURATION IN 

Follow the procedure above from points 

1

 to 

3

.

   

Associate the relay module directly with Amazon Echo Plus, Echo Show or Echo Studio.

 

1) Press the front push button until the LED flashes. Download the Zigbee software onto the 

device using the View Wireless App (see the View Wireless App manual). 
To update the software on the device, the procedure is the same. 

2) After conversion to Zigbee technology (or the software update), the actuator automatically 

goes into pairing mode so that it can be recognised by the Amazon device within 5 minutes. If 
the actuator is not in pairing mode, cut off the power supply and restore it after a few seconds.

3) Associate the actuator with Amazon Echo Plus, Echo Show or Echo Studio according to the 

procedure envisaged by the voice assistant (see the Amazon documentation).

Set the actuator parameters.    

1) Within the first 5 minutes after the device has been powered (already associated with Alexa), 

press the front push button for 15 s; this way, you can select the relay operation - between 
one-position stable and two-position stable (the LED flashes green for the two-position stable 
setting and amber for the one-position stable setting). 

2) Briefly press the front push button to switch from two-position stable to one-position stable 

and vice versa; once the choice has been made, press the front push button for 5 s to confirm. 
If you have set the two-position stable setting, the LED flashes green three times, whereas if you 
have chosen the one-position stable setting, you will move on to the next step (3).

3) Press the front push button for 5 s to set the one-position stable activation time. Press the front 

push button briefly, the output is activated and the LED lights up amber permanently; at the end 
of the time you wish to set, press the front push button again. The output is deactivated and 
the LED flashes amber for 3 times to confirm the setting made.

N.B. 

When the voltage returns after a power outage, the relay maintains the state in which it was 

prior to the power supply cut out.

Summary of Zigbee technology mode signalling.

• During normal operation:

LED

Meaning

On 

(amber for Eikon, blue for Arké, green for Idea and 

Plana)

Relay active

Off

Relay not active

• In the configuration phase:

LED

Meaning

Flashing white 

(for max 5 min.)

Zigbee mode active pending 

voice assistant 

Flashing blue 

(for max 2 min.)

Pending receipt of 

a fw update

Blue permanently lit

Device associated via Bluetooth 

with the smartphone

Flashing green during 

one-position/two-position stable config-

uration  

(for max 5 min.)

Setting in two-position stable

Flashing amber during 

one-position/two-position stable config-

uration  

(for max 5 min.)

Setting in one-position stable

Amber permanently lit  

One-position stable time setting

Flashing green 3 times 

Confirms two-position stable setting 

 

Flashing amber 3 times

Confirms one-position stable setting

  

Flashing green rapidly 

3 times 

Device correctly 

associated with the voice assistant 

 

On 

(amber for Eikon, blue for Arké, 

green for Idea and Plana)

Relay active 

during normal operation 

 

CONTROLLABLE LOADS. 

Loads

Heating

100 V~

16 A

8 A

30 W

0.5 A

4 A

16 (3.5) A

240 V~

16 A

8 A

100 W

0.5 A

4 A

16 (3.5) A

RESETTING THE RELAY MODULE.

The reset restores the factory settings. Within the first 5 minutes from powering, press the front 
push button for 30 s until LED flashes white. 

 INSTALLATION RULES.

• Installation must be carried out by qualified persons in compliance with the current regula-

tions regarding the installation of electrical equipment in the country where the products are 
installed.

• The device must be installed in flush mounting boxes or surface mounting boxes with Eikon, 

Arkè , Idea and Plana mounting frames and cover plates.

• Installation must be carried out in mounting boxes with a depth of more than 48 mm.
• The relay output power circuit must be protected against overloads by installing a device, fuse 

or automatic 1-way switch, with a rated current not exceeding 16 A.

CHARACTERISTICS.

• Rated supply voltage: 100-240 V~, 50/60 Hz.
• Dissipated power: 0.85 W
• RF transmission power: < 100mW (20dBm)
• Frequency range: 2400-2483.5 MHz
• Terminals:

- 2 terminals (L and N) for line and neutral
- 1 terminal (1) for the relay output in voltage

• 1 front push button for load control and for configuration/reset.

If configured in the “Energy” application, it forces the output ton for the time set on the 
View App.

• RGB LED indicating the output status (which can be set from the View Wireless App) and the 

configuration status (flashing blue)

• In Bluetooth technology mode, you can associate up to 2 radio devices (art. 03925) which 

make it possible to control the actuator or activate a scenario.       

• Operating temperature: -10 ÷ +40 °C (indoor)