Fig. 3

Fig. 1

Fig. 2

Fig. 4

Fig. 5

Fig. 6

SE

SA

230V~

50Hz

A

B

5 4 3 2 1

6

SE

B

A

- NON MANTAINED (SE)

WIRING DIAGRAMS

Always connect the main voltage SE

 

Do not short the A B terminals if you are using the 02795

A

B

5 4 3 2 1

6

B

A

- MANTAINED (SA)

  

WIRING DIAGRAMS

SE

SA

Always connect the main voltage SE

 

Do not short the A B terminals if you are using the 02795

  230V~

50Hz

SE

  230V~

50Hz

SA

Max 128 luminaires on this Bus Line. 500m Max Cable Extension.

 Max 128 luminaires on this Bus Line. 500m Max Cable Extension.

 Max 128 luminaires on this Bus Line. 500m Max Cable Extension.

Max 128 luminaires on this Bus Line. 500m Max Cable Extension.

Bus Termination

Bus Termination

Bus Termination

on the Repeater.

 Max 128 luminaires on this Bus Line. 500m Max Cable Extension.

 Max 128 luminaires on this Bus Line. 500m Max Cable Extension.

Max 128 luminaires on this Bus Line. 

500m Max Cable Extension.

Power supply 230V

~

L

N

Luminaires Offices buildings

Luminaires workshops buildings

Luminaires Technical locals

Luminaires Technical locals 2

T

T

T

Connection to the central using 02829 and 02828 repeaters.  

Line Bus 

2

Line Bus 

1

Downstairs

Basement

First Floor

Second Floor

Third Floor

Fourth Floor

Bus

Termination

Bus

Termination

Bus

Termination

Bus

Termination

T

T

T

T

T

BUS 

4

BUS 

3

BUS 

2

BUS 

1

IN

OUT

BUS MASTER

02828

IN

OUT

BUS MASTER

BUS 

2

BUS 

1

T

02829

T

The bus

 

used must have a bipolar, 

twisted

 and 

shielded

 

cable (min. 2x0,5 mm²). The connection is a 

Point to 

Point 

type, i.e. input and output of the fixtures must be, 

as shown in fig. no. 2. The connection must be done 

respecting the polarity of "

A

" and "

B

" both on the lamps 

and on the plant.

B

B

A

A

Respect the polarity of the Bus

J8

Attention:

For a correct operation of the whole plant it is necessary 

to

 terminate the bus

, inserting the jumpers, supplied 

with the plant or with the repeater, on the strips inside 

the electronic board of all the lamps that are placed at 

the end of the lines of each series.

If at the end there is repeater, it is necessary to terminate 

it as if it were a fixture, the strip is between the terminal 

board of Bus In and Bus Out

Bus Termination

SE

SA

 230V~

50Hz

A

B

5 4 3 2 1

6

SE

REST MODE

(OPTIONAL)

- NON MANTAINED (SE)

WIRING DIAGRAMS

Do not short the A B terminals if you are using the 02795

B

A

230V~

02795

REST CONTROL

02795

POWER

EMERGENCY

STATE

ON

OFF

EMERGENCY

MODE

A

B

Always connect the main voltage SE

 

SE

SA

  230V~

50Hz

A

B

5 4 3 2 1

6

REST MODE

(OPTIONAL)

- MANTAINED (SA)

 

 230V~

50Hz

SE

SA

WIRING DIAGRAMS

Always connect the main voltage SE

 

Do not short the A B terminals if you are using the 02795

B

A

230V~

02795

REST CONTROL

02795

POWER

EMERGENCY

STATE

ON

OFF

EMERGENCY

MODE

A

B

CONNECTION FOR E-WAY TEST LAMPS

CONNECTION FOR AUTO TEST LAMPS

SE SA B A

INHIBITION

SE SA B A

REST MODE

INHIBITION / REST MODE

B A

B

A

bridge

02795

REST CONTROL

02795

POWER

EMERGENCY

STATE

ON

OFF

EMERGENCY

MODE

A

B

USER INFORMATION IN COMPLIANCE WITH DIRECTIVE 2002/96 (RAEE)

In order to prevent damage to the environment and human health as well as incur

-

ring administrative sanctions, appliances bearing this symbol must be disposed of 
separately from urban waste, or handed in to the distributor when buying a new 
one. Appliances marked with the above symbol must be collected in conformity 
with the instructions issued by the local authorities in charge of waste disposal. For 
more information call the free-phone number 800-862307.

Содержание E-way 02703

Страница 1: ...iante veloce Batteria in ricarica Led Verde lampeggiante lento Test in corso Led Rosso lampeggiante lento Test disabilitati e lampada in inibizione Led Rosso lampeggiante veloce Guasto della batteria Led Rosso acceso fisso Anomalia della lampada UTILIZZO Permanente SA la lampada è sempre accesa utilizzo tipico per l illuminazione di segnalazione Non Permanente SE la lampada si accende solo quando ...

Страница 2: ...stato e schermato La tipologia di connessione deve essere Punto Punto ossia si deve entrare ed uscire da ogni plafoniera come è visibile negli schemi a lato Il collegamento deve essere fatto rispettando le polarità di A e B sia sulle lampade che sulla centrale B B A A Rispettare la polarità del Bus J8 Avvertenze Per un corretto funzionamento di tutto l impianto occorre Terminare il Bus inserendo i...

Страница 3: ...the lamp is always on typical used for indicator lighting Non Permanent SE the lamp only switches on when there is a mains power cut typical used for emergency lighting LAMPS WITH AUTO TEST FUNCTION LAMPS WITH E WAY TEST FUNCTION INSTALLATION RULES Installation should be carried out observing current installation regulations for electrical systems in the country where the products are installed CO...

Страница 4: ...and on the plant B B A A Respect the polarity of the Bus J8 Attention For a correct operation of the whole plant it is necessary to terminate the bus inserting the jumpers supplied with the plant or with the repeater on the strips inside the electronic board of all the lamps that are placed at the end of the lines of each series If at the end there is repeater it is necessary to terminate it as if...