Vimar E-way 02703 Скачать руководство пользователя страница 3

Viale Vicenza, 14 - I 36063 Marostica VI 

Tel. +39 0424 488 600 - Fax (Export) +39 0424 488 709

www.vimar.eu

Instruction sheet

E-way

02703-02704-02705-02706-02709-02710-02713-02714-02719-02720
02723-02724-02725-02726-02729-02730-02733-02734-02739-02740

GENERAL CHARACTERISTICS.

• Power supply: 230 V~, 50 Hz .
• Indicator green Led for the presence of the power supply and for the charge of the 

battery.

• Indicator red led for the inhibition mode.
• Operation with rechargeable Ni-Cd and NiMH batteries.
• Constant current electronic device for the charge of the battery.
• Electrical protection device for the excessive discharge of battery.
• Possibility to be put in the stand-by mode by remote control 02795 (optional)
• Plastic body in accordance with the rules in force.
• Protection degree: IP40.
• Insulating class: II 

.

INSTALLATION.

The following procedure must be performed by qualified personnel only.
1) Remove the transparent cover pushing with a screwdriver;

2) Unhook the body of the lamp from the base with a screwdriver;

3) Drill if necessary one of the three possible entries for the power supply cable and 
fix the base to the wall using the holes on the base;

4) Make the connections illustrated in figures 1 or 2 or 4 or 5.
5) Hook the body to the base making release the tooth;
6) Hook the transparent cover to the base making release the tooth.

Important: In the case of flush mounting the product must be installed with the 
LED facing uppermost.

BATTERIES

:

It is recommended to substitute each battery every four years or when the nominal 
autonomy is not guaranteed. The model and the date of production of the battery are 
written on it. Fill the field with the date of the first starting.

Warning: The Ni-Cd and Ni-MH batteries are sold uncharged: the first charge 
must be 48h long.

WARNING:

Dispose of batteries in the specific differentiated collection bins.

OPERATION.

• The lamp provides auxiliary lighting in the event of a mains power failure.
• When the mains power returns the lamp will automatically switch off and the green 

LED will switch on.

• Battery charging takes place continuously when there is mains voltage.

TEST FUNCTIONS.

• The lamp makes three kinds of deliberate time tests: the battery test, the functional 
test and the duration test. The functional test and the duration test can be made also 
in the manual way with the use of the 02795 in the normal charge mode.
• All the manual tests can be made only if there is the good ambient condition of 
external light. If theexternal conditions aren’t good the test is postponed to the first 
coming of the good conditions. In the time of waiting the green led flashes to indicate 
that the lamp is waiting for the test.

The battery test

: is done every 24 hours, it is an internal test on the conditions 

of the battery. 

The functional test

: is done every 15 days and consists in the lighting of the fluorescent 

lamp for a duration of 5 seconds. To start the manual functional test push one time the  
02795 ON (make a short push no more than 2 seconds) 

The duration test

: is done every 90 days and consists in the complete discharge 

of the battery. To start the duration test push one time the 02795 ON (make a long 
push no less than 5 seconds).

Disabilitation of the tests

: all deliberate time tests can be disabled with a pushing 

of the button of 02795 OFF, with a second pushing of the 02795 ON deliberate time 
tests will be enabled.

LED SIGNALLING.
Green Led On 

= Mains supply on, no warning

Green Led Fast Flashing 

= Battery in fast charge

Green Led Slow Flashing 

= Test in 

progress

Red Led Slow Flashing 

= Test disabled and inhibit luminaire

Red Led Fast Flashing 

= Battery fault

Red Led On 

= Warning luminaire

USE

.

• Permanent (

SA

): the lamp is always on (typical used for indicator lighting).       

• Non-Permanent (

SE

): the lamp only switches on when there is a mains power 

cut (typical used for emergency lighting).

LAMPS WITH AUTO-TEST FUNCTION:

LAMPS WITH E-WAY TEST FUNCTION:

INSTALLATION RULES.

Installation  should  be  carried  out  observing  current  installation  regulations  for 
electrical systems in the country where the products are installed.

CONFORMITY TO STANDARDS.

LV directive. Standards EN 60598-1, EN 60598-2-22, EN 60598-2-2.
EMC directive. Standards EN 61547, EN 61000-3-2, EN 61000-3-3, EN 55015.

1.

1.

2.

3.

3.

Surface mounting emergency lighting device, supply voltage 230 
V~ 50 Hz, rechargeable battery. Provided with lamp.

ART.

LAMPADA

AUT.

TIPO BATTERIA

NiCd 6V 0,8Ah

NiCd 6V 2,5Ah
NiCd 6V 1,3Ah
NiMH 6V 3,3Ah

1h
3h
1h
3h

02703
02704
02705
02706
02713
02714
02709
02710
02719
02720

11W - 2G7
11W - 2G7

FLUSSO (lm) FLUSSO (lm)

139
135
195
215

   – 
   – 

NiCd 6V 1,3Ah
NiMH 6V 3,3Ah

   – 
   – 

8W - G5

8W - G5

8W - G5

8W - G5

1h
3h

142
143

288
290

NiCd 6V 1,8Ah

NiCd 6V 1,8Ah

NiMH 6V 4,0Ah

NiMH 6V 4,0Ah

NiCd 6V 1,8Ah

NiCd 6V 1,8Ah

NiMH 6V 4,0Ah

NiMH 6V 4,0Ah

312

312

294

294

284

284

308

308

445

445

445

445

24W - 2G11

24W - 2G11

24W - 2G11

24W - 2G11

24W - 2G11

24W - 2G11

24W - 2G11

24W - 2G11

1h

1h

3h

3h

1h

1h

3h

3h

RICARICA

12h
12h
12h
24h
12h
24h

12h

12h

24h

24h

12h

12h

24h

24h

POT.

3
3
3
3

11
11

W

  3

  3

  3

  3

15

15

15

15

Fig. 4
Fig. 4
Fig. 4
Fig. 4
Fig. 5
Fig. 5

Fig. 4
Fig. 4
Fig. 5
Fig. 5

NiCd 6V 0,8Ah
NiCd 6V 2,5Ah
NiCd 6V 1,3Ah
NiMH 6V 3,3Ah

1h
3h
1h
3h

11W - 2G7
11W - 2G7

139
135
195
215

   – 
   – 

NiCd 6V 1,3Ah
NiMH 6V 3,3Ah

   – 
   – 

8W - G5

8W - G5

8W - G5

8W - G5

1h
3h

142
143

288
290

12h
12h
12h
24h
12h
24h

3
3
3
3

11
11

Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 2
Fig. 2
Fig. 2
Fig. 2
Fig. 2
Fig. 2

02723
02724
02725
02726

02733
02734
02729
02730
02739
02740

SE

SA

ART.

LAMPADA

AUT.

TIPO BATTERIA

NiCd 6V 0,8Ah

NiCd 6V 2,5Ah
NiCd 6V 1,3Ah
NiMH 6V 3,3Ah

1h
3h
1h
3h

02703
02704
02705
02706
02713
02714
02709
02710
02719
02720

11W - 2G7
11W - 2G7

FLUSSO (lm) FLUSSO (lm)

139
135
195
215

   – 
   – 

NiCd 6V 1,3Ah
NiMH 6V 3,3Ah

   – 
   – 

8W - G5

8W - G5

8W - G5

8W - G5

1h
3h

142
143

288
290

NiCd 6V 1,8Ah

NiCd 6V 1,8Ah

NiMH 6V 4,0Ah

NiMH 6V 4,0Ah

NiCd 6V 1,8Ah

NiCd 6V 1,8Ah

NiMH 6V 4,0Ah

NiMH 6V 4,0Ah

312

312

294

294

284

284

308

308

445

445

445

445

24W - 2G11

24W - 2G11

24W - 2G11

24W - 2G11

24W - 2G11

24W - 2G11

24W - 2G11

24W - 2G11

1h

1h

3h

3h

1h

1h

3h

3h

RICARICA

12h
12h
12h
24h
12h
24h

12h

12h

24h

24h

12h

12h

24h

24h

POT.

3
3
3
3

11
11

W

  3

  3

  3

  3

15

15

15

15

Fig. 4
Fig. 4
Fig. 4
Fig. 4
Fig. 5
Fig. 5

Fig. 4
Fig. 4
Fig. 5
Fig. 5

NiCd 6V 0,8Ah
NiCd 6V 2,5Ah
NiCd 6V 1,3Ah
NiMH 6V 3,3Ah

1h
3h
1h
3h

11W - 2G7
11W - 2G7

139
135
195
215

   – 
   – 

NiCd 6V 1,3Ah
NiMH 6V 3,3Ah

   – 
   – 

8W - G5

8W - G5

8W - G5

8W - G5

1h
3h

142
143

288
290

12h
12h
12h
24h
12h
24h

3
3
3
3

11
11

Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 2
Fig. 2
Fig. 2
Fig. 2
Fig. 2
Fig. 2

02723
02724
02725
02726

02733
02734
02729
02730
02739
02740

SE

SA

ART.

LAMPADA

AUT.

TIPO BATTERIA

NiCd 6V 0,8Ah

NiCd 6V 2,5Ah
NiCd 6V 1,3Ah
NiMH 6V 3,3Ah

1h
3h
1h
3h

02703
02704
02705
02706
02713
02714
02709
02710
02719
02720

11W - 2G7
11W - 2G7

FLUSSO (lm) FLUSSO (lm)

139
135
195
215

   – 
   – 

NiCd 6V 1,3Ah
NiMH 6V 3,3Ah

   – 
   – 

8W - G5

8W - G5

8W - G5

8W - G5

1h
3h

142
143

288
290

NiCd 6V 1,8Ah

NiCd 6V 1,8Ah

NiMH 6V 4,0Ah

NiMH 6V 4,0Ah

NiCd 6V 1,8Ah

NiCd 6V 1,8Ah

NiMH 6V 4,0Ah

NiMH 6V 4,0Ah

312

312

294

294

284

284

308

308

445

445

445

445

24W - 2G11

24W - 2G11

24W - 2G11

24W - 2G11

24W - 2G11

24W - 2G11

24W - 2G11

24W - 2G11

1h

1h

3h

3h

1h

1h

3h

3h

RICARICA

12h
12h
12h
24h
12h
24h

12h

12h

24h

24h

12h

12h

24h

24h

POT.

3
3
3
3

11
11

W

  3

  3

  3

  3

15

15

15

15

Fig. 4
Fig. 4
Fig. 4
Fig. 4
Fig. 5
Fig. 5

Fig. 4
Fig. 4
Fig. 5
Fig. 5

NiCd 6V 0,8Ah
NiCd 6V 2,5Ah
NiCd 6V 1,3Ah
NiMH 6V 3,3Ah

1h
3h
1h
3h

11W - 2G7
11W - 2G7

139
135
195
215

   – 
   – 

NiCd 6V 1,3Ah
NiMH 6V 3,3Ah

   – 
   – 

8W - G5

8W - G5

8W - G5

8W - G5

1h
3h

142
143

288
290

12h
12h
12h
24h
12h
24h

3
3
3
3

11
11

Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 2
Fig. 2
Fig. 2
Fig. 2
Fig. 2
Fig. 2

02723
02724
02725
02726

02733
02734
02729
02730
02739
02740

SE

SA

Содержание E-way 02703

Страница 1: ...iante veloce Batteria in ricarica Led Verde lampeggiante lento Test in corso Led Rosso lampeggiante lento Test disabilitati e lampada in inibizione Led Rosso lampeggiante veloce Guasto della batteria Led Rosso acceso fisso Anomalia della lampada UTILIZZO Permanente SA la lampada è sempre accesa utilizzo tipico per l illuminazione di segnalazione Non Permanente SE la lampada si accende solo quando ...

Страница 2: ...stato e schermato La tipologia di connessione deve essere Punto Punto ossia si deve entrare ed uscire da ogni plafoniera come è visibile negli schemi a lato Il collegamento deve essere fatto rispettando le polarità di A e B sia sulle lampade che sulla centrale B B A A Rispettare la polarità del Bus J8 Avvertenze Per un corretto funzionamento di tutto l impianto occorre Terminare il Bus inserendo i...

Страница 3: ...the lamp is always on typical used for indicator lighting Non Permanent SE the lamp only switches on when there is a mains power cut typical used for emergency lighting LAMPS WITH AUTO TEST FUNCTION LAMPS WITH E WAY TEST FUNCTION INSTALLATION RULES Installation should be carried out observing current installation regulations for electrical systems in the country where the products are installed CO...

Страница 4: ...and on the plant B B A A Respect the polarity of the Bus J8 Attention For a correct operation of the whole plant it is necessary to terminate the bus inserting the jumpers supplied with the plant or with the repeater on the strips inside the electronic board of all the lamps that are placed at the end of the lines of each series If at the end there is repeater it is necessary to terminate it as if...