Viale Vicenza, 14
36063 Marostica VI - Italy
www.vimar.com
49400927C0 02 1911
By-alarm
01728
The three LEDs will emit a fast blink and then go out; this indicates access to Menu
1. Lastly, release the
PROG
button.
Selecting the desired menu
To select the desired menu, briefly press the
PROG
button; each time it is pressed
the LEDs change status, showing the related menu item as shown in the table
below:
LEDs on
Descriptions of the menu
R
G
V
Menu 1
- IN and Tamper configuration
Menu 2
- Pyroelectric configuration 1
Menu 3
- Pyroelectric configuration 2
Menu 4
- Channel configuration
Menu 5
- Supervision and LEDs configuration
Menu 5
- Transmission capacity configuration
Legend:
R
=Red LED,
G
=Amber LED,
V
=Green LED.
N.B.
In the following contents the default configuration is indicated by
*
.
The R and V LEDs display the selectable options and the G LED, activated/
deactivated with the TAMPER button, confirms the selected one.
•
Menu 1
When
all LEDs are off
you are in Menu 1.
- Press the
SELECT
push-button to enter the configuration; the three LEDs will
blink 3 times to confirm the selection made.
- Using the
TAMPER
push-button to edit and the
PROG
push-button to scroll
through the options, set the desired function as shown in the table below:
LEDs on
Amber LED off
Amber LED on
R
V
IN: NC (normally closed)
*
IN: NO (normally open)
Tamper off
*
Tamper on
- To save and return to the main menu, press the
SELECT
button; to save and exit
configuration completely, briefly press the
RESET
button.
•
Menu 2
When the
amber LED is on
you are in Menu 2.
- Press the
SELECT
push-button to enter the configuration; the three LEDs will
blink 3 times to confirm the selection made.
- Using the
TAMPER
push-button to edit and the
PROG
push-button to scroll
through the options, set the desired function as shown in the table below:
LEDs on
Amber LED off
Amber LED on
R
V
Pyroelectric off
*
Pyroelectric on
Blind Time: 4 min
*
Blind Time: 2 min
N.B.
: Blind Time is the period of suspension of pyroelectric detection so as to
optimise energy saving. This period of suspension is activated when an alarm
is detected and ends at the end of the programmed time.
- To save and return to the main menu, press the
SELECT
button; to save and exit
configuration completely, briefly press the
RESET
button.
•
Menu 3
When the
green LED is on
you are in Menu 3.
- Press the
SELECT
push-button to enter the configuration; the three LEDs will
blink 3 times to confirm the selection made.
- For this menu, only one of the functions must be active; using the
PROG
button, scroll through the options until you find the desired configuration and
press the
TAMPER
button to confirm the choice that
will be highlighted by the
amber LED coming on
.
LEDs on
Functions
R
V
1 pulse
*
2 Bipolar pulses
3 Bipolar pulses
4 Pulses of any polarity
- To save and return to the main menu, press the
SELECT
button; to save and exit
configuration completely, briefly press the
RESET
button.
•
Menu 4
When the
green and amber LEDs are on
you are in Menu 4.
- Press the
SELECT
push-button to enter the configuration; the three LEDs will
blink 3 times to confirm the selection made.
- For this menu, only one of the functions must be active; using the
PROG
button, scroll through the options until you find the desired configuration and
press the
TAMPER
button to confirm the choice that
will be highlighted by the
amber LED coming on
.
LEDs on
Functions
R
V
*
In IN: all on channel 1
Infrared: on channel 1
IN: on channel 2
- To save and return to the main menu, press the
SELECT
button; to save and exit
configuration completely, briefly press the
RESET
button.
•
Menu 5
When the
red LED is on
you are in Menu 5.
- Press the
SELECT
push-button to enter the configuration; the three LEDs will
blink 3 times to confirm the selection made.
- Using the
TAMPER
push-button to edit and the
PROG
push-button to scroll
through the options, set the desired function as shown in the table below:
LEDs on
Amber LED off
Amber LED on
R
V
Supervision off
*
Supervision on
Supervision interval 8 min
*
Supervision interval 20 min
- To save and return to the main menu, press the
SELECT
button; to save and exit
configuration completely, briefly press the
RESET
button.
•
Menu 6
When the
red and amber LEDs are on
you are in Menu 6.
- Press the
SELECT
push-button to enter the configuration; the three LEDs will
blink 3 times to confirm the selection made.
- For this menu, only one of the functions must be active; using the
PROG
button, scroll through the options until you find the desired configuration and
press the
TAMPER
button to confirm the choice that
will be highlighted by the
amber LED coming on
.
LEDs on
Functions
R
V
Normal power
*
Medium power
Maximum power
- To save and return to the main menu, press the
SELECT
button; to save and exit
configuration completely, briefly press the
RESET
button.