By-alarm

01704

By-alarm configurable 8-input expansion module for potential-free 
contacts, cord for roller shutter, passive non-piezoelectric shock 
detectors, with additional power supply battery status control function.

TECHNICAL CHARACTERISTICS

• Power supply: 12 V ± 20%
• Absorption: 18 mA max
• Input lines: No. 8 with single, double and triple balancing
• Connections: with 4 wires to one of the serial ports for connection to the RS485 bus
• Operating temperature: -10..+40 °C (indoor use)
• Degree of safety: 2 (EN 50131-3)
• Ambient class: II (EN 50131-3)

• The 8-input expansion module 01704 is compatible with the control units 01700, 

01700.120, 01703 and 01703.120 having firmware version 1.2 or later; before 
installing the device, use the keyboard 01705 to check the firmware version of 
the control unit in the system. Alternatively, check that the tracking code shown 
on the label of the control unit on which you are installing the device is equal to 
or greater than XXXXXXXXXX1.02.

INSTALLING THE EXPANSION MODULES

The module is connected to the control unit to one of the bus serial ports, following 
the instructions given in the control unit's installation manual and respecting the 
warnings.
• For installation, use halogen-free shielded cables suitable for installation with 

Category 1 power cables (U0 = 400 V) such as cable art. 01733 (2x0.50 
mm

2

+2x0.22 mm

2

). 

• For the power supply, use wires with a minimum cross-section of 0.50 mm

2

 observ-

ing the c and - polarity. 

• Connect the signal cables A and B using conductors with a minimum section equal 

to 0.22 mm

2

• The length of the connection with the wired sensors must not exceed 100 m.
• The shielding must be connected to the negative on the control unit side and left 

free on the expansion module side.

Input zones

The module has 8 inputs and 2 push-buttons for protection against opening the 
enclosure and against tearing it off the wall. The push-buttons protecting against 
opening and against removal on the zone expansion card can be cut off by closing the 
relevant jumpers alongside the buttons. The power supply to any sensors is carried 
by the 2 terminals marked 

+

 and 

-

  , protected by the 

resettable 500 mA fuse F1

 next 

to the power supply terminals.

Recessed connector

The device has a recessed connector; 

it must not be used under any circumstances 

as it is for internal testing and firmware updating; improper use may damage the 
circuit.

ADDRESSING THE EXPANSION MODULES

For them to be recognised by the control unit, the expansion modules need to be 
addressed by setting the DIP-switches on the printed circuit board; the settings that 
can be made are listed in the following table:

EXPANSION NO.

DIP-SWITCH NO.

1

2

3

4

5

6

EXPANSION 1

OFF

OFF

OFF

OFF

OFF

OFF

EXPANSION 2

ON

OFF

OFF

OFF

OFF

OFF

EXPANSION 3

OFF

ON

OFF

OFF

OFF

OFF

EXPANSION 4

ON

ON

OFF

OFF

OFF

OFF

EXPANSION 5

OFF

OFF

ON

OFF

OFF

OFF

EXPANSION 6

ON

OFF

ON

OFF

OFF

OFF

EXPANSION 7

OFF

ON

ON

OFF

OFF

OFF

EXPANSION 8

ON

ON

ON

OFF

OFF

OFF

EXPANSION 9

OFF

OFF

OFF

ON

OFF

OFF

EXPANSION 10

ON

OFF

OFF

ON

OFF

OFF

EXPANSION 11

OFF

ON

OFF

ON

OFF

OFF

EXPANSION 12

ON

ON

OFF

ON

OFF

OFF

EXPANSION 13

OFF

OFF

ON

ON

OFF

OFF

EXPANSION 14

ON

OFF

ON

ON

OFF

OFF

Caution: The maximum number of expansion modules that can be installed 
depends on the type of control unit used. 
If the addressing made with the DIP-switches is changed with the module 
switched on, to make it operational you need to press the push-button PB2 or 
power cycle the device.

Amber LED  

The amber LED on the expansion module lets you control functionality as follows:
• 

On steady

: module properly powered but no serial communication.

• 

Blinking at a frequency of 1 s

: module powered correctly and receiving serial 

communications but these are sent with an incorrect address or no configuration 
of the device in the control unit.

• 

Blinking with one short pulse every second

: module powered properly and 

correct serial communication.

FRONT VIEW

CONNECTIONS TO THE CONTROL UNIT

CN5

20

D
E

A B

RS 485

BC

MC

TI

+

M4

M5

M8

L1 

L2 

L3 

L4

L5

L6

L7

L8

+

+

B

T

T

DE

A

+

1
2
3
4
5
6

ON

RS485 bus line

01700-01700.120

01703-01703.120

01704

Tear-proof cut-off 

S3

Anti-opening 
cut-off 

S4

Inputs

Dip-switch for settings
address

Reset button 

PB2

Connector not 
used

BC

MC

TI

+

M4

M5

M8

L1 

L2 

L3 

L4

L5

L6

L7

L8

+

+

B

T

T

DE

A

+

1

2

3

4

5

6

ON

Tamperproof

Connection with power supply 01717-01717.120 

S1 

and 

S2