Description
The Steely series cover plates are used to create panel compositions for door entry and video door entry systems using
Due Fili Plus technology.
Can be flush mounted using the specific rip-proof flush mounting boxes: 41592 (2 module), 41593 (3 module), and 41594 (4 module).
The cover plates are supplied with frame and must be completed with flush mounting box, any additional cover plates, electronic unit
and relative additional components supplied separately, chosen according to the type of system.
The instructions refer only to mounting the panel, for full installation, connection and programming, please refer to the
electronic unit manual.
Technical characteristics
• Protection class: IP54
• IK08-rated for protection against impact (except for Audio/Video cover plates for alphanumeric electronic units 41540 and 41541:
IK07).
Installation
Installation procedure:
1. Install the rip-proof flush-mounted box at a height of approx. 1.65 m, or 1.20 m for accessibility for the disabled, from the upper
edge of the box on the ground (Fig. 1).
- The box must be installed in the correct mounting direction following the indication
UP
found on the bottom of the box.
- If installation requires the use of several boxes, use the special connection bars and screws provided to join them together
(Fig. 4).
- Set the boxes into the wall, passing the cable ducts through the special holes in the sides (use the knockouts created for this
purpose).
2. Secure the module-holder frame to the electronic unit terminal block using the screws supplied (fig. 5).
3. Secure the module-holder frame to the box using the screws supplied (fig. 6).
4. Connect the terminal block of the electronic unit to the system, following the wiring diagrams in the reference manual depending
on the type of system.
5. Connect the electronic unit by means of the wiring on the upper section of the electronic unit.
6. Connect
any additional modules (if used):
- When using conventional push button panels, connect any additional modules; they should be connected one after the other
by means of the wiring supplied with the modules, and finally connected to the standard electronic unit by means of the wiring
in its lower section.
- In the case of installation of additional panels with luminous name plates (Art. 41542), connect the LED lighting boards Art.
R260.B (supplied installed in the frames) to the terminal block on the electronic unit, as indicated in the connection variants
shown in the electronic unit manual.
7. Insert the electronic unit and any additional modules in the frames (use the connector supplied with the additional modules to
secure them together).
8. Connect the microphone inserted in its seat, in the lower right hand side of the frame, to the electronic unit (fig. 7).
9. Configure and programme the panel parameters, using the buttons on the electronic modules or by connecting to a PC and using
the system management software.
10.
Where it is possible to print name labels, these must be fitted in the front panels with buttons or the name holder plates. To
remove the labels, press lightly on the back of the cover plate to remove the label holder on the rear of the button module (Fig.
10)
11. Close the panel and fix it to the box (Fig. 8).
The instructions manual can be downloaded from the website
www.vimar.com
3
EN
STEELY