9 Datasheet Villagepump
Dimensions
1,73m x 0,50m x 0,62m (h x w x d);
including packaging: 1,76 m x 0,53 m x 0,75 m (l x w x
h);
Weight
Villagepump complete:
app. 80 / 89 kg
Villagepump incl. packaging:
app. 99 / 107 kg
Performance¹
Max 8 l/min
Installation connections
¾" - from generation 7 onward
(inlet, drain)
Maximum suction/static head: 3 meter; maximum
distance to water: 10 meter
Technology
0,05 mm mesh membrane / 0,08 washable membrane
Capillary Ultrafiltration membranes
Activated carbon cartridge
Cleaning
Automatic high-pressure backwash
Periodical chlorine dispensing
Biological retention
Viruses
> 99.99% (log 4) ²
Bacteria
> 99.9999% (log 6) ³
Cyst removal
> 99.9999% (log 6)
Membrane approvals/
NSF 61 /
KIWA
compliances
Storage and handling
Villagepump should be stored dry and protected against
freezing. After first use Villagepump should be operated
at regular times (preferable at daily base). When stored
for a longer time, special treatment is needed.
Operating conditions
Ambient temperature min +1°C, max +45°C
Feed water temperature min +5° C, max +35°C
Activated Carbon cartridge
20" carbon block (2,5" diameter), minimal flow 450 L/h
¹ Flow rates and capacity depend on incoming water conditions
² Tested by VITENS water research using MS2 bacteriophages
³ Tested by VITENS water research using Bacillus Spores