![Viking VWH2410 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/viking/vwh2410/vwh2410_installation-manual_1025876006.webp)
INSTALLING HOOD CANOPY
(VBCV/VICV Custom Ventilator Kits Only)
A
B
30” W.
27 7/16” (69.7 cm)
21 7/16” (54.5 cm)
36” W.
33 7/16” (84.9 cm)
21 7/16” (54.5 cm)
42” W.
39 7/16” (100.2 cm)
21 7/16” (54.5 cm)
48” W.
45 7/16” (115.4 cm)
21 7/16” (54.5 cm)
54” W.
51 7/16” (130.7 cm)
21 7/16” (54.5 cm)
60” W.
57 7/16” (145.9 cm)
21 7/16” (54.5 cm)
66” W.
63 7/16” (161.1 cm)
21 7/16” (54.5 cm)
Custom Hood Canopy Cutouts
Make sure the back wall of the custom hood canopy is flush with the cutout so the ventilator system may be mounted
as shown below.
Custom Hood Canopy
1) Position ventilator
system inside of the
custom hood canopy
and center it front to
back and left to right.
2) Bottom mounting holes
fasten ventilator system
to bottom of custom
hood canopy with the
screws provided
Built-in Ventilator System
3) OPTIONAL
Rear mounting holes fasten
ventilator system to rear of custom
hood canopy
*For best results, center the unit over the burners of the cooking product (front to back; right to left).
Wall Hoods
A
B
36” W.
33 7/16” (84.9 cm)
27 9/16” (70.0 cm)
42” W.
39 7/16” (100.2 cm)
27 9/16” (70.0 cm)
54” W.
51 7/16” (130.7 cm)
27 9/16” (70.0 cm)
66” W.
63 7/16” (161.1 cm)
27 9/16” (70.0 cm)
Island Hoods
6
A
B