WALL HOOD DIMENSIONS  
(Indoor/Outdoor VWH Models)    

FOR 900, 1200 or 1500 CFM EXTERIOR 

VENTILATOR INSTALLATION

18”
(45.7 cm)

6” (15.2 cm)

24” (61.0 cm)
or 27” (68.6 cm)

1 1/2” 

(3.81 cm)

1” (2.54 cm)

8 1/4” 

(20.9 cm)

2 1/2”(6.35 cm)

5 15/16”

(

15.1cm

)

6 7/16”
(16.4cm)

3” (7.62 cm)

1 1/16”
(2.7 cm)

A

A

18 3/4” (47.6 cm)

93/8”

(23.8 cm)

9 1/8”

(23.2 cm)

9 5/8”

(24.4 cm)

FOR 900 or 1200 CFM EXTERIOR

VENTILATOR INSTALLATION

24”, 30”, 36”, 42” W. Models

FOR 300 or 600 CFM INTERIOR

VENTILATOR INSTALLATION

24”, 30”, 36”, 42” W. Models

4 5/8”

(11.7 cm)

B

5/8” (1.6 cm)

B

12”

(30.5 cm)

Cutout for 10”
(25.4 cm) duct.

7” (17.8 cm) dia.
Duct Location

*Note:  “Dotted Line” (........) represents cutout

120

V

FOR 300, 600 or 1200 CFM INTERIOR 

VENTILATOR INSTALLATION

24” (61.0 cm)
or 27” (68.6 cm)

18”

(45.7 cm)

1 1/2” 

(3.81 cm)

7/8”

(2.22 cm)

9” (22.9 cm)

Transition 
VIV1200 Only

9 3/4” (24.8 cm)

Содержание VWH2410

Страница 1: ...Viking Installation Guide Built In 18 H Hoods Indoor and Outdoor Models...

Страница 2: ...e National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 3 When cutting or drilling into wall...

Страница 3: ...CFM1 HALOGEN FILTERS SPACERS MAX AMPS3 LIGHTS Int Interior Ext Exterior Interior Exterior 36 W 1200 int 1200 ext 1500 ext 2 2 2 8 7 6 1 6 8 48 W 1200 int 1200 ext 1500 ext 3 3 2 11 5 8 8 9 5 60 W 1200...

Страница 4: ...72 167 6 cm 182 9 cm 66 72 167 6 cm 182 9 cm HEIGHT OF OUTDOOR HOOD The bottom of the hood should be 30 76 2 cm to 36 91 4 cm above the grill surface The hood should be installed 4 1 2 11 4 cm plus t...

Страница 5: ...er cable from service panel to installation location See Basic Specifications on page 13 for the maximum amp requirements Top Mounting Holes Wood Strip provided locally 11 2 x3 4 Slot for Wood Strip R...

Страница 6: ...be mounted as shown below Custom Hood Canopy 1 Position ventilator system inside of the custom hood canopy and center it front to back and left to right 2 Bottom mounting holes fasten ventilator syst...

Страница 7: ...n to plate before attaching plate to hood 3 Remove wire box cover Remove a knockout from the wiring box Feed 6 of power cable through opening and attach cable to wiring in wiring box with appropriate...

Страница 8: ...r Kit 300 or 600 CFM also see instructions supplied with ventilator kit 1 Make sure barrel nuts and wing nut are engaged halfway onto threaded stud 2 Lift ventilator into canopy may be easier to turn...

Страница 9: ...of power cable through the openings and attach cables to wiring box with appropriate connectors 4 Wire black to black white to white and green or bare wire beneath green ground screw Replace wiring bo...

Страница 10: ...e upper two thirds of the shingles around the cutout area Carefully lift the shingles to allow the back flashing sheet on the blower housing to fit under them 9 Center the blower ring in the 11 27 9 c...

Страница 11: ...cm diameter hole making sure that the 11 4 3 2 cm diameter electrical wiring hole aligns with the hole in the wiring box 9 Attach blower to the wall with the six screws provided It is recommended tha...

Страница 12: ...nd the top and sides of the cutout area only Carefully lift the shingles to allow the back flashing sheet on the blower housing to fit under them 9 Center the blower ring in the 11 27 9 cm diameter ho...

Страница 13: ...hole aligns with the hole in the wiring box 9 Attach blower to the wall with the six screws provided All six holes in the back panel must be filled or any moisture that may get inside the housing cou...

Страница 14: ...151 2 39 4 cm 281 4 71 8 cm VEV900 EXTERIOR BLOWER LINE IN 120 VAC 60 HZ 15 AMP MAX WIRING BOX GREEN BLACK WHITE BLACK BLACK BLACK WHITE GREEN WHITE WHITE GREEN VEV1200 VEV1500 22 1 8 56 2 cm B 10 1 8...

Страница 15: ...3 8 cm 9 1 8 23 2 cm 9 5 8 24 4 cm FOR 900 or 1200 CFM EXTERIOR VENTILATOR INSTALLATION 24 30 36 42 W Models FOR 300 or 600 CFM INTERIOR VENTILATOR INSTALLATION 24 30 36 42 W Models 4 5 8 11 7 cm B 5...

Страница 16: ...15 16 76 0 cm 66 W Models 65 7 8 167 3 cm 32 15 16 83 7 cm FOR 1200 or 1500 CFM EXTERIOR VENTILATOR INSTALLATION 48 54 60 66 W Models FOR 1200 CFM INTERIOR VENTILATOR INSTALLATION 30 36 42 48 54 60 66...

Страница 17: ...T IN CUSTOM VENTILATOR SYSTEM DIMENSIONS VBCV Models 900 or 1200 CFM EXTERIOR VENTILATOR INSTALLATION 30 36 42 W Models 300 or 600 CFM INTERIOR VENTILATOR INSTALLATION 30 36 42 W Models D 8 1 4 20 9 c...

Страница 18: ...0 W Models 58 1 4 148 0 cm 29 1 8 74 0 cm 66 W Models 64 1 4 163 2 cm 32 1 8 81 6 cm D 8 1 4 20 9 cm 6 15 2 cm 5 1 2 14 0 cm 3 7 6 cm 2 1 2 6 4 cm Cutout for 10 25 4 cm duct D 9 3 8 23 8 cm 9 1 2 24 4...

Страница 19: ...cm C D 36 W Models 35 7 8 91 1 cm 17 15 16 45 56 cm 42 W Models 41 7 8 106 4 cm 20 15 16 18 18 cm 54 W Models 53 7 8 136 8 cm 26 15 16 68 42 cm 66 W Models 65 7 8 167 3 cm 32 15 16 83 66 cm D C FOR 12...

Страница 20: ...RNAL POWER INTERNAL POWER 120 V 120 V 5 8 1 6 cm 5 8 1 6 cm B B 9 3 8 23 8 cm 9 5 8 24 4 cm 1 3 16 3 0 cm A A 8 1 4 21 0 cm 5 3 4 14 6 cm 6 15 2 cm 3 7 6 cm 2 1 2 6 4 cm 18 3 4 47 6 cm 9 1 8 23 2 cm 5...

Страница 21: ...A B 54 W Model 52 1 4 132 7 cm 26 1 8 66 4 cm 66 W Model 64 1 4 163 2 cm 32 1 8 81 6 cm 5 8 1 6 cm B A 8 1 4 21 0 cm 5 3 4 14 6 cm 6 15 2 cm 3 7 6 cm 2 1 2 6 4 cm Cutout for 10 25 4 cm duct 9 1 2 24...

Страница 22: ...1R PS042707J Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For more product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange...

Отзывы: