PROBLEM CHECK
POSSIBLE
CAUSE
REMEDY
c. High and low 1. Compressor valve failure, 1. Replace compressor and
side
pressure preventing
compressor
drier, evacuate and
in the sealed
from developing required recharge with refrigerant
system.
refrigerant pressures for
to the proper amount.
system
operation.
2. Restriction in the sealed
2. Locate the restriction and
refrigerant system
correct the cause. Evacuate,
causing high compressor replace drier and recharge
discharge pressures and
the sealed refrigeration
low pressure or vacuum
system to the proper level.
Conditions on the suction
side. Pressure does not
equalize quickly when
the compressor is turned
off.
d. Interior light-- 1. Striker plate on bottom
1. Replace or install striker
does it remain of door not present or
plate on door so light
on with door
not positioned properly
switch is depressed when
closed, adding to depress light switch in door is closed.
heat to the
grille area when door is
closed.
2. Failed light activation
2. Replace light activation
switch not turning off
switch.
light when switch is
depressed.
3. Wiring connection to or
3. Correct improper wiring
from light activation
connection.
switch improperly wired
bypassing switch.
4.
Door
light
activation
4. Place over-ride switch in
switch over-ride switch
the “door” position. Verify
in the “on” position
light goes out when door
permitting light to remain is closed by depressing
“on” with door closed.
Light activation switch
(Present on some but
and confirming light goes
not all models.)
out.