source of a leak. The braze ways cannot be brazed/repaired. The evaporator assembly must be
replaced to repair a leak in this area.
Occasionally, corrosion develops under the thermo-bulb mounting clamp causing a leak, so leak
check this area thoroughly. Also, if this is the leak source, replace the evaporator assembly.
Hopefully, this information will help you properly diagnose sealed refrigeration system leak
conditions which you encounter on Viking all-refrigerator models in the field. When these
problems are properly diagnosed and promptly repaired, the customer, the service technician and
Viking all benefit.
TROUBLESHOODTING FOR VIKING ALL-REFRIGERATOR
AND WINE STORAGE ALL-REFRIGERATOR MODELS
PROBLEM CHECK
POSSIBLE
CAUSE
REMEDY
1. Interior too a. Thermostat
1. Thermostat set to
1. Adjust thermostat to warmer
cold or
setting
too cold of a
setting (lower number on
contents .
setting for ambient
knob)
freezing.
conditions.
b. The evaporator
1. Refrigerant leak
1. locate and correct cause of
for the presence
or low refrigerant
refrigerant leak. Replace
of a uniform
charge in the
drier, evaporator, and
frost pattern
sealed system.
Recharge sealed
Is the frost
Refrigerant volume
refrigerant system with
confined to left
is evaporator is not
the proper amount of
wing and left
sufficient to cool
charge as listed on the
side of the
the region of the
unit’s data plate.
back? Note
plate where the
compressor
evaporator plate
should be
sensing thermo-
operating for at
stat’s thermo-bulb
least 5 minutes
mounts. Therefore
with door open
the control thermo-
to perform this
stat never reaches
check. See
its cut-out
previous page
temperature and
for explanation
the compressor
unique problem.
Operates 100% of
the time. The
remaining
evapor-
ator
volume
is
sufficient
to
cool
the
air
temperature
below
freezing.
F90571
6