Viking VIPR102 Скачать руководство пользователя страница 12

12

VIKING RANGE, LLC

Downdraft Ventilators

USE AND CARE

Always turn the downdraft blower 
on before you begin cooking to es-
tablish an air fl ow in the kitchen. Let 
the blower run for a few minutes 
to clean the air after you turn the 
cooktop off. This will keep the 
whole kitchen cleaner and brighter. 
The activating switch is pressed 
and the air vent rises.

Cleaning

Use a mild detergent suitable for painted surfaces. DO NOT USE 
ABRASIVE CLOTH, STEEL WOOL PADS, OR SCOURING POW-
DERS. Vacuum blower to clean. Do not immerse blower in water.

Wash the 2 aluminum/stainless 
steel grease fi lters in a mild de-
tergent solution or a dishwasher. 
Remove them from the air vent 
by grasping the tab at the top of 
each fi lter.

Servicing

It may be necessary to remove the downdraft blower system from 
the cabinet in order to service components such as the blower 
motor or air vent mechanism.

Disconnect power to the cooktop and remove it fi rst. Reverse 
the steps under “MOUNT THE UNIT” to remove the downdraft 
from the cabinet.

All Units

OPERATION

All Units

UP / DOWN ---

Raises and lowers 
vent.

 

Turns blower ON 
when vent is UP 
and OFF when vent is DOWN.

Note: 

The UP/DOWN switch for models VIPR102SS, 

VIPR162SS, and VIPR182SS is on the right hand end of the 
top cover.

DELAY ------------

Allows blower to run for 10 min. after button is 
pressed. Delay is activated by holding 
down any speed control button until the 
LED indicator fl ashes. Blower will run for 
10 min. - then shut OFF. 

VENT WILL NOT 

LOWER. 

You must press UP / DOWN to lower 

vent. When DELAY is activated, the speed 
level light will blink.

BLOWER SPEEDS --------

Blower operates at 4 different speed 
levels. Press button ONCE to turn 
blower ON to desired speed. Press 
button AGAIN to turn blower OFF.

FILTER LIGHT ---------------

Comes ON after 30 hours of opera-
tion to remind you to clean fi lters. 
Press button to reset.

WARNING: Always disconnect electric power 
supply before cleaning and/or servicing unit.

1

2

3

4

FILTER

RESET

UP/DO

WN

REMOTE CONTROL

FOR MODELS

VIPR102RSS
VIPR162RSS
VIPR182RSS

TOP COVER CONTROL
FOR MODELS
VIPR102SS
VIPR162SS
VIPR182SS

Содержание VIPR102

Страница 1: ...r d Use proper pan size Always use cookware appropriate for the size of the surface element TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWINGa 1 SMO...

Страница 2: ...ps It can be mounted in island peninsula or conventional wall locations Thisunitcanbeeasilyinstalled following these basic steps Cut out the countertop opening Mount the unit in the cabinet Install 10...

Страница 3: ...equivalent feet of transitions and or elbows to be used should equal 40 feet or less NOTE The equivalent feet of various roof and wall caps has been taken into consideration Do not include them in thi...

Страница 4: ...P 10 CENTER LINE OF COUNTER CUTOUT CENTER LINE OF DUCT CUTOUT 2 10 10 ROUND DIA CUTOUT TYP 3 6 CENTER LINE OF DUCT CUTOUT can be located within this area CENTER LINE OF COUNTER CUTOUT 19 10 10 ROUND C...

Страница 5: ...LOCATION OF ELECTRICAL OUTLET If Models VIPR102SS or VIPR102RSS are being installed in a 30 wide cabinet or Models VIPR162SS or VIPR162RSS are being installed in a 36 wide cabinet or Models VIPR182SS...

Страница 6: ...r cover 4 Carefully position the10 discharge plate under the bottom flange of the downdraft 5 Connect motor plug 6 Replace the gear motor cover and 2 sheet metal screws 7 Replace the 2 clamp channels...

Страница 7: ...4 30 36 48 B 20 1 4 20 1 4 18 3 4 18 3 4 24 24 24 C 27 33 27 33 27 33 45 D 2 1 4 2 1 4 3 3 2 3 4 2 3 4 2 3 4 E 7 8 7 8 1 1 2 1 1 2 1 1 2 F 7 8 7 8 1 1 16 1 1 4 1 1 2 1 1 2 1 1 2 A C B D F E A C B D F...

Страница 8: ...m secure and air tight 3 Connect ductwork to downdraft If necessary LOOSEN nuts and screws that hold remote blower adapter plate in place and slide outlet assembly left or right to meet ductwork Re ti...

Страница 9: ...the paper from the adhesive back of the control line the control up with the three holes and position the control so it is parallel with the front of the counter top Press down firmly for 60 seconds 4...

Страница 10: ...10 Downdraft Ventilators VIKING RANGE LLC This page has been left blank intentionally BACKSIDE OF REMOTE SWITCH TEMPLATE...

Страница 11: ...und power cable from the remote blower to wiring box on 10 round discharge plate 5 Connectdowndraftwiringtopowercablefromremoteblower Wire black to black white to white and green to green or bare wire...

Страница 12: ...e it first Reverse the steps under MOUNT THE UNIT to remove the downdraft from the cabinet All Units OPERATION All Units UP DOWN Raisesandlowers vent Turns blower ON when vent is UP and OFF when vent...

Страница 13: ...whether arising out of breach of warranty breach of contract or otherwise Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or...

Страница 14: ...ri e Toujours utiliser une batterie de cuisine proportionnelle l l ment de surface AFIN DE DIMINUER LES RISQUES DE BLESSURES POUVANT SURVENIR LORSQU UN FEU SE D CLENCHE SUR LA SURFACE DE CUISSON SUIVE...

Страница 15: ...surface de cuisson COMPTOIR BOUCHE DE CHEMIN E CONDUIT ROND DE 25 4 cm 10 po PLAQUE D VACUATION DE 25 4 cm 10 po SP CIFICATIONS LECTRIQUES 120 VCA 60 Hz 6 0 A max SP CIFICATIONS LECTRIQUES 120 VCA 60...

Страница 16: ...SUITE GALE UN CONDUIT DROIT DE 61 CM 2 PI VUE DE C T DE LA HOTTE AVEC VENTILATEUR INT RIEUR VIDV500 VUE DE C T DE LA HOTTE AVEC COUDE ROND DE 25 4 cm 10 po pour connexion au ventilateur ext rieur VEDV...

Страница 17: ...ancher les montants des murs les c bles lectriques et les tuyaux de nuisent pas Ventilateurs encastr s 61 2 cm 24 1 8 po LIGNE DE CENTRE DU D COUPAGE DU COMPTOIR 14 cm 5 1 2 po LIGNES DE CENTRE DU D C...

Страница 18: ...s mod les VIPR102SS ou VIPR102RSS sont install s dans une armoire de 76 2 cm 30 po de largeur ou les mod les VIPR162SS ou VIPR162RSS sont instal l s dans une armoire de 91 4 cm 36 po de largeur ou les...

Страница 19: ...s la bride inf rieure de la hotte 5 Branchez la prise du moteur 6 Replacez le couvercle du moteur et les 2 vis m tal 7 Replacez les 2 profil s et engagez les 4 crous sans serrer 8 Glissez le ventilate...

Страница 20: ...3 8 cm 33po 114 3 cm 45po D 5 7 cm 2 po 5 7 cm 2 po 7 6 cm 3 po 7 6 cm 3 po 7 cm 2 po 7 cm 2 po 7 cm 2 po E 2 2 cm 7 8 po 2 2 cm 7 8 po 3 8 cm 1 po 3 8 cm 1 po 3 8 cm 1 po F 2 2 cm 7 8 po 2 2 cm 7 8 p...

Страница 21: ...hes 3 Raccordez le conduit la hotte Au besoin DESSERREZ les crous et les vis qui maintiennent la plaque d adaptateur du ventilateur et glissez la gauche ou droite pour l aligner avec le conduit Resser...

Страница 22: ...trique de la plaque d vacuation de 25 4 cm 10 po de diam tre 5 Raccordez les fils de la hotte au c ble d alimentation du ventilateur Raccordez le noir avec le noir le blanc au blanc et le vert au vert...

Страница 23: ...s et vitez les endroits o un chaudron chaud pourrait tre d pos ou des liquides chauds renvers s 4 Sortez les deux crous en nylon du sachet de plastique et installez les sur les goujons de la t l comma...

Страница 24: ...24 Downdraft Ventilators VIKING RANGE LLC Ventilateurs encastr s Cette page a t laiss e en blanc volontairement ARRI RE DU GABARIT DE LA T L COMMANDE...

Страница 25: ...s mod les FONCTIONNEMENT Tous les mod les HAUT BAS Rel ve ou abaisse l e c o n d u i t d a ration Met le ventilateur en MARCHE lorsque le conduit est RELEV et ARR TE le ventilateur lorsque le conduit...

Страница 26: ...inobservation d une garantie de la violation d un contrat ou de toute autre cause Certaines juridictions interdisant l exclusion ou la limitation des dommages indirects ou cons cutifs il se peut que...

Страница 27: ...tama o adecuado Siempre use utensilios de cocina que sean apropiados para el tama o del elemento de la superficie TPARA REDUCIR EL RIESGO DE LESIONES A PERSONAS EN CASO DE UN INCENDIO PRODUCIDO POR G...

Страница 28: ...estos pasos b sicos Monte la unidad en el gabinete Instale la placa de descarga redonda de 10 pulg 25 cm Instale el ventilador exterior modelo VEDV900 o VEDV1200 s lo el modelo de 48 pulg 120 cm Cone...

Страница 29: ...e ha tomado en consideraci n la longitud equivalente en pies de varias tapas de techo y pared No las incluya en este c lculo TRANSICI N REDONDA DE 3 1 4 X 10 pulg 8 2 x 25 cm A 6 pulg 15 2 cm 1 pulg 2...

Страница 30: ...GABINETE L NEA CENTRAL DEL CORTE PARA EL CONDUCTO 2 pulg 7 cm RECORTE REDONDO DE 10 pulg 25 cm T pico 3 pulg 8 9 cm 6 pulg 15 9 cm L NEA CENTRAL DEL CORTE DEL CONDUCTO se puede situar dentro de esta r...

Страница 31: ...SS se van a instalar en un gabinete de 30 pulg 75 cm de ancho o si los modelos VIPR162SS o VIPR162RSS se van a instalar en un gabinete de 36 pulg 90 cm de ancho o si los modelos VIPR182SS o VIPR182RSS...

Страница 32: ...de inferior del tiro descendente 5 Conecte el enchufe del motor 6 Vuelva a colocar la cubierta del motor de engranaje y los 2 tornillos autorroscantes 7 Vuelva a colocar los 2 canales de sujeci n y ap...

Страница 33: ...C 27 pulg 68 6 cm 33 pulg 83 8 cm 27 pulg 68 6 cm 33 pulg 83 8 cm 27 pulg 68 6 cm 33 pulg 83 8 cm 45 pulg 114 3 cm D 2 1 4 pulg 5 7 cm 2 1 4 pulg 5 7 cm 3 pulg 7 6 cm 3 pulg 7 6 cm 2 3 4 pulg 7 cm 2 3...

Страница 34: ...s al tiro descendente Si es necesario AFLOJE las tuercas y los tornillos que fijan la placa adaptadora del ventilador remoto en su lugar y deslice el conjunto de la salida hacia la izquierda o hacia l...

Страница 35: ...orificios y coloque el control de tal manera que quede paralelo con el frente del gabinete Oprima firmemente durante 60 segundos 4 Saque las dos tuercas de mariposa de nailon de la bolsa de pl stico y...

Страница 36: ...36 Ventiladores de tiro descendente VIKING RANGE LLC Esta p gina se ha dejado en blanco intencionalmente PARTE POSTERIOR DE LA PLANTILLA DEL CONMUTADOR REMOTO...

Страница 37: ...de cableado en una placa de descarga de 10 pulg 25 cm 5 Conecte el cableado del tiro descendente al cable el ctrico desde el ventilador remoto Conecte negro con negro blanco con blanco y verde con ve...

Страница 38: ...o descendente del gabinete Todas las unidades FUNCIONAMIENTO Todas las unidades ARRIBA ABAJO Subeybajaelsistema de ventilaci n Enciendeelventilador cuando el sistema est ARRIBA y lo apaga cuando el si...

Страница 39: ...o incidentales que surjan por el incumplimiento de la garant a incumplimiento de contrato o de otra manera Algunas jurisdicciones no permiten la exclusi n o limitaci n de da os incidentales o consecue...

Страница 40: ...Las especificaciones est n sujetas a cambios sin previo aviso Si desea m s informaci n sobre el producto llame al 1 845 4641 o visite el sitio web en http www vikingrange com 99044605C F20073C SP...

Отзывы: