Viking VGWT241T Скачать руководство пользователя страница 7

7

Gas Connection

The gas supply (service) line must be the same size or greater than the inlet line of the appliance.  This range uses a
1/2” (1.3 cm) ID NPT (Sch40) inlet.  Sealant on all pipe joints must be resistive to LP gas. 
1.  Manual shut-off valve:

This installer-supplied valve must be installed in the gas service line ahead of the appliance in the gas stream and in a
position where it can be reached quickly in the event of an emergency.  In Massachusetts:  A “T” handle type manual
valve must be installed in teh gas supply line to the appliance.

2.  Pressure Regulator:

a)  All heavy-duty, commercial type cooking equipment must have a pressure regulator on the incoming service line for

safe and efficient operation, since service pressure may fluctuate with local demand.  External regulators are not
required on this range since a regulator is built into each unit at the factory.  Under no condition bypass this built-in
regulator.

b)  Any conversion required must be performed by your dealer or a qualified licensed plumber or gas service company.

Please provide the service person with this manual before work begins.  (Gas conversions are the responsibility of the
dealer or end user).

c)  This range can be sued with Natural or LP/Propane gas.  It is shipped from the factory adjusted for use with natural

gas.  The orifice hoods must be screwed snug when LP/Propane is used.  (See LP/Propane conversion.)

d)  Manifold pressure should be checked with a manometer, natural gas requires 5.0” W.C.P. and LP gas requires 10.0”

W.C.P.  Incoming line pressure upstream from the regulator must be 1” W.C.P. higher than the manifold pressure in
order to check the regulator.  The regulator used on this range can withstand a maximum input pressure of 1/2” PS
(14.0” W.C.P.).  If the line pressure is in excess of that amount, a step down regulator will be required.

e)  The appliance, its individual shut-off valve, and pressure regulator must be disconnected from the gas supply piping

system during any pressure testing of that system at pressures in excess of 1/2 psig (3.45 kPa)

f)  The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during

any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.45 kPa)

2.  Flexible Connections:

If the unit is to be installed with flexible couplings and/or quick-disconnect fittings, the installer must use a heavy-duty AGA
design-certified flexible connector of at least 1/2” (1.3 cm) ID NPT (with suitable strain reliefs) incompliance with ANSI
Z21.41 and Z21.69.  In Canada: CAN 1-6, 10-88 metal connectors for gas appliances and CAN 1-6.9 M79 quick
disconnect devices for use with gas fuel.  In Massachusetts:  This appliance must be installed with a 36” (3-foot) long
flexible gas connector

Electrical Connection in this area
Gas Connection in either area

2” (5.1 cm)
Dia.

2 3/4” (7.0 cm)

31 1/16”

(78.9 cm)

2 1/2”

(6.4 cm)

1 3/4”

(4.4 cm)

4 3/8”

(11.1 cm)

23 7/16”

(59.5 cm)

28 5/16”

(71.9 cm)

CAUTION:

Leak testing of the

appliance shall be conducted
according to the manufacturer’s
instructions.  Before placing the
oven into operation, always check
for leaks with a soapy water
solution or other acceptable
method.  DO NOT USE AN OPEN
FLAME TO CHECK FOR LEAKS!

Содержание VGWT241T

Страница 1: ... touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department 3 Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If not installed operated and maintained in accordance with...

Страница 2: ...D gas service line Maximum amp usage 240V 6098 watts 25 4 amps 6B 240V 6634 watts 27 6 amps 6G 240V 8914 watts 37 1 amps 208V 4757 watts 22 9 amps 208V 5163 watts 24 8 amps 208V 6994 watts 33 6 amps 4G 240V 7462 watts 31 1 amps 6Q 240V 8050 watts 33 5 amps 208V 5880 wattts 28 3 amps 208V 6245 watts 30 0 amps 4Q 240V 6634 watts 27 6 amps 4GQ 240V 8914 watts 37 1 amps 208V 5163 watts 24 8 amps 208V ...

Страница 3: ...P Propane 10 0 W C P 10 Flexible Connection If the unit is to be installed with flexible couplings and or quick disconnect fittings the installer must use a flexible connector approved by national and local codes 11 The misuse of oven doors e g stepping sitting or leaning on them can result in potential hazards and or injuries WARNING ELECTRICAL GROUNDING INSTRUCTIONS This appliance must be electr...

Страница 4: ...nction efficiently B Left Side A Right Side Front Back Front Back Adjustable Legs Adjustable Legs Stability Device Installation Instructions 1 The anti tip bracket is to be attached to the rear wall as shown The dimension for the bracket location from the floor is to be determined after the range legs have been adjsuted to the proper installation height shown in the installation instructions and t...

Страница 5: ...cm above the floor Refer to the rangehood installation instructions for additional information These dimensions provide for safe and efficient operation of the hood 30 76 2 cm min 36 91 4 cm max 66 72 167 6 cm 182 9 cm 30 76 2 cm min 36 91 4 cm max 66 72 167 6 cm 182 9 cm 36 91 4 cm ISLAND INSTALLATION WALL INSTALLATION 36 91 4 cm Metal Hood Metal Hood Wood Composite Overlay Wood Composite Overlay...

Страница 6: ...e clearance must be 18 45 7 cm above the 36 91 4 cm high countertop 4 Wall cabinets above the range must be a minimum of 42 106 7 cm above the range cooking surface for the full width of the range This minimum height requirement does not apply if a rangehood is installed over the cooking surface Overall Width 30 W Models 29 7 8 75 9 cm 36 W Models 35 7 8 91 1 cm 48 W Models 47 7 8 121 6 cm Electri...

Страница 7: ...ng line pressure upstream from the regulator must be 1 W C P higher than the manifold pressure in order to check the regulator The regulator used on this range can withstand a maximum input pressure of 1 2 PS 14 0 W C P If the line pressure is in excess of that amount a step down regulator will be required e The appliance its individual shut off valve and pressure regulator must be disconnected fr...

Страница 8: ... supply cord pushing supply cord up toward terminal block to relieve strain before tightening 6 Reattach access door 4 Wire Power Supply Cord 1 Remove access door 2 Remove supply cord strain relief bracket and 3 supply cord mounting screws on the terminal block 3 Remove grounding screw cut off and discard ground strap 4 Feed supply cord up thru the hole in the bottom of the range back 5 Attach the...

Страница 9: ...rews and attach line 1 red to the left terminal line 2 black to the right terminal the neutral wire white to the center terminal 6 Reattach the access door 4 Wire Power Connection 1 Remove access door 2 Remove strain relief mounting angle and reattach as shown 3 Feed 1 2 1 3 cm trade size conduit through the hole in the bottom of the range back and secure to the strain relief bracket with a condui...

Страница 10: ...urner valve and engage the slotted low flame adjustment screw The low flame should be a small flame that comes just to the top edge of the burner Rotate the adjusting screw clockwise to low th flame or counter clockwise to increase the flame Turn the burn off and relight several times turning to the low position The low flame should light at every port each time Readjust as needed 1 1 2 3 8 cm 3 8...

Страница 11: ...inate yellow tipping b Close the air shutter gap to prevent a noisy flame that lifts off the burner Screw front of burner Screw rear of burner TUBE BURNER Air shutter adjustment screw 12 Grill Assembly 24 Grill Assembly 1 2 3 4 5 6 1 Grill Grates 2 Flavor Generator plates 3 Heat Deflector 4 Grill Frame 5 Grill Burner Sheild Do not remove from burner 6 Burner Do not remove ITEM A Air shutter Griddl...

Страница 12: ...en abort self clean cycle to unlock door CAUTION Do not run self clean cycle for more than 10 minutes with oven racks and rack supports inside oven This could cause them to discolor due to the high temperature required for self cleaning Final Preparation 1 Some stainless steel parts may have a plastic protective wrap which must be removed The interior of the oven should be washed thoroughly with h...