background image

Specifications 

7

Dimensions 

6

21”

(53.3

 cm)

   30-3/4”

(78.1 cm)

21”

(53.3 cm)

36-3/4”

(93.3 cm)

1”

(2.5 cm)

2-1/2”

(6.4 cm)

5”

(12.7 cm)

13/16”

(2.1 cm)

6-19/32”

(16.7 cm)

30” Gas Cooktop

36” Gas Cooktop

Professional Gas Cooktops

Description

VGSU104

VGSU164

Overall width

30-3/4” (78.1 cm)

36-3/4” (93.3 cm)

Overall height from bottom
to top of grate

5” (12.7 cm)

Overall depth from rear

21” (53.3 cm)

Cutout width

26-7/8” (68.3 cm) min. to

29-7/8” (75.9 cm) max.

34-3/8” (87.3 cm) min. to 

35-7/8” (91.1 cm) max.

Cutout height

2-1/2” (6.4 cm)

Cutout depth

18-5/8” (47.3 cm) min. to 

20-1/8” (51.1 cm)

Gas requirements

To field convert from natural or LP/Propane, the orifice spuds and regulator 

must be physically changed. Order conversion kit NK2VGSU to convert to 

natural and LPK3VGSU to convert to LP. Uses standard residential 

1/2” (1.3 cm) I.D. gas service line. 

Electrical requirements

120 VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 

3-prong plug attached to product.

Maximum amp usage

2.0 amps

Surface element rating

Left front

Left rear

Center front/rear

Right front

Right rear

16,000 Nat./15,500 LP (BTU)

(4.8 Nat./4.65 LP (kw))

12,000 Nat./11,500 LP (BTU)

(3.6 Nat./3.45 LP (kw))

N/A

6,000 Nat./5,500 LP (BTU)

(1.8 Nat./1.65 LP (kw))

8,000 Nat./7,500 LP (BTU)

(2.4 Nat./2.25 LP (kw))

16,000 Nat./15,500 LP (BTU)

(4.8 Nat./4.65 LP (kw))

12,000 Nat./11,500 LP (BTU)

(3.6 Nat./3.45 LP (kw))

12,000 Nat./11,500 LP (BTU)

(3.6 Nat./3.45 LP (kw))

6,000 Nat./5,500 LP (BTU)

(1.8 Nat./1.65 LP (kw))

8,000 Nat./7,500 LP (BTU)

(2.4 Nat./2.25 LP (kw))

Approximate 

shipping weight

67 lb. (30.2 kg)

80 lb. (36.0 kg)

Front view

Right side view

Содержание VGSU104

Страница 1: ...ional Built In Gas Cooktops Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at v...

Страница 2: ...R WARNING or CAUTION These words mean Hazards or unsafe practices which WILL result in severe personal injury or death DANGER Hazards or unsafe practices which COULD result in severe personal injury o...

Страница 3: ...if a gas leak occurs Formaldehyde and soot are byproducts of incomplete combustion Properly adjusted burners with a bluish rather than yellow flame will minimize incomplete combustion WARNING ELECTRI...

Страница 4: ...hanged Order conversion kit NK2VGSU to convert to natural and LPK3VGSU to convert to LP Uses standard residential 1 2 1 3 cm I D gas service line Electrical requirements 120 VAC 60 Hz 4 ft 121 9 cm 3...

Страница 5: ...2 6 4 cm 36 min 91 4 cm 28 1 8 71 4 cm 5 12 7 cm max toe kick 28 1 2 72 4 cm 2 6 7 8 7 3 3 c m 2 1 2 6 4 c m m i n 1 2 1 4 3 1 1 c m 1 4 5 8 3 7 2 c m 14 1 4 36 2 cm 14 1 4 36 2 cm 18 5 8 47 3 cm 30 W...

Страница 6: ...aces above 36 91 4 cm high There must be a minimum of 8 20 3 cm side clearance from the cooktop to such combustible surfaces above the 36 91 4 cm counter height Within the 8 20 3 cm side clearance to...

Страница 7: ...uirements There is no connection necessary beyond plugging the unit into a polarized grounded 120 volt 60 Hz 15 amp circuit A minimum of 120VAC is required for proper operation of gas ignition systems...

Страница 8: ...ld current 120 volts 60 Hz 15 amps single phase Electrical installation should comply with national and local codes Air Supply and Ventilation Means must be provided for any heavy duty cooking applian...

Страница 9: ...el parts should be wiped regularly with hot soapy water and with a liquid cleanser designed for this material if build up occurs DO NOT USE steel wool abrasive cloths cleansers or powders If it is nec...

Страница 10: ...u will need it if service is ever required Model number ____________________________________________________________________________________ Serial number _____________________________________________...

Отзывы: