background image

IMPORTANT

5

Please Read and Follow

IMPORTANT

4

Please Read and Follow

FIRE/EXPLOSION
HAZARD

IF THE INFORMATION IN
THIS MANUAL IS NOT

FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL
INJURY, OR DEATH.
• 

DO NOT

store or use gasoline or other

flammable vapors and liquids in the
vicinity of this or any other appliance.

• WHAT TO DO IF YOU SMELL GAS:

DO NOT

try to light any appliance.

DO NOT

touch any electrical switch.

DO NOT

use any phone in your

building.

–Immediately call your gas supplier

from a neighbor’s phone.

–Follow the gas supplier’s instructions.
–If you cannot reach your gas supplier,

call the fire department.

• Installation and service must be

performed by a qualified installer,
service agency, or the gas supplier.

DANGER

CHEMICAL HAZARD

If not installed, operated and
maintained in accordance
with the manufacturer’s

instructions, this product could expose
you to substances in fuel or from fuel
combustion which can cause death or
serious illness and which are known to
cause cancer, birth defects, or other
reproductive harm.

For example, benzene is a chemical
which is part of the gas supplied to the
cooking product. It is consumed in the
flame during combustion. However
exposure to a small amount of benzene
is possible if a gas leak occurs.
Formaldehyde and soot are byproducts
of incomplete combustion. Properly
adjusted burners with a bluish rather
than yellow flame will minimize
incomplete combustion.

WARNING

ELECTRICAL GROUNDING
INSTRUCTIONS

The cooktop must be electrically grounded
in accordance with local codes or, in the
absence of codes, with the ANSI/NFPA 
No. 70-latest edition. Installation should
be made by a licensed electrician. This
appliance is equipped with a three-prong
grounding plug for your protection against
shock hazard and should be plugged
directly into a properly grounded
receptacle. 

DO NOT

cut or remove the

grounding prong from the plug.

For personal safety, this appliance
must be properly grounded. DO NOT
under any circumstances cut or
remove the third (ground) prong from
the power plug

.

WARNING

BURN HAZARD

The use of cabinets for storage above the
appliance may result in a potential burn
hazard. Combustible items may ignite,
metallic items may become hot and
cause burns. If a cabinet storage is to be
provided the risk can be reduced by
installing a range hood that projects
horizontally a minimum of 5” (12.7 cm)
beyond the bottom of the cabinets.

CAUTION

Before placing the cooktop into operation,
always check for gas leaks with a soapy
water solution or other acceptable method.

DO NOT

USE AN OPEN FLAME TO

CHECK FOR LEAKS.

CAUTION

This appliance shall not be used for
space heating. This information is based
on safety considerations.

WARNING

Содержание VGSU104

Страница 1: ...ional Built In Gas Cooktops Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at v...

Страница 2: ...R WARNING or CAUTION These words mean Hazards or unsafe practices which WILL result in severe personal injury or death DANGER Hazards or unsafe practices which COULD result in severe personal injury o...

Страница 3: ...if a gas leak occurs Formaldehyde and soot are byproducts of incomplete combustion Properly adjusted burners with a bluish rather than yellow flame will minimize incomplete combustion WARNING ELECTRI...

Страница 4: ...hanged Order conversion kit NK2VGSU to convert to natural and LPK3VGSU to convert to LP Uses standard residential 1 2 1 3 cm I D gas service line Electrical requirements 120 VAC 60 Hz 4 ft 121 9 cm 3...

Страница 5: ...2 6 4 cm 36 min 91 4 cm 28 1 8 71 4 cm 5 12 7 cm max toe kick 28 1 2 72 4 cm 2 6 7 8 7 3 3 c m 2 1 2 6 4 c m m i n 1 2 1 4 3 1 1 c m 1 4 5 8 3 7 2 c m 14 1 4 36 2 cm 14 1 4 36 2 cm 18 5 8 47 3 cm 30 W...

Страница 6: ...aces above 36 91 4 cm high There must be a minimum of 8 20 3 cm side clearance from the cooktop to such combustible surfaces above the 36 91 4 cm counter height Within the 8 20 3 cm side clearance to...

Страница 7: ...uirements There is no connection necessary beyond plugging the unit into a polarized grounded 120 volt 60 Hz 15 amp circuit A minimum of 120VAC is required for proper operation of gas ignition systems...

Страница 8: ...ld current 120 volts 60 Hz 15 amps single phase Electrical installation should comply with national and local codes Air Supply and Ventilation Means must be provided for any heavy duty cooking applian...

Страница 9: ...el parts should be wiped regularly with hot soapy water and with a liquid cleanser designed for this material if build up occurs DO NOT USE steel wool abrasive cloths cleansers or powders If it is nec...

Страница 10: ...u will need it if service is ever required Model number ____________________________________________________________________________________ Serial number _____________________________________________...