4
Features
Keyless entry codes ..........................................................................................
Relay activation time in sec (00-99, 00 = 0.5 sec, factory set to 05) ..................
Relay activation code (0-9*, 00-99, or
, factory set to
) ............................
Security code (factory set to 845464) ................................................................
To enter a
(relay activation or keyless entry codes only)** .............................
Entry device may dial through unit ....................................................................
Entry device may not dial through unit (factory setting) .....................................
Keyless entry codes enabled ............................................................................
Keyless entry codes disabled (factory setting) ..................................................
Exit programming ..............................................................................................
Restore all programming to factory defaults ......................................................
1-6 digits
2 digits
1-2 digits
6 digits
1
2
3
4
##7
###
#00 - #31
#40
#41
#47
* When a single digit relay activation code is programmed (0-9), the activation touch tone must be held for a minimum of 120 msec. Most cell phones
and some cordless phones produce short touch tones below 100msec in length regardless of the length of time the digit is held, it is recommended
to use a 2-digit activation code in these situations.
** Entering a
uses one digit location and can only be used in the relay activation code or keyless entry codes.
Note:
A double beep indicates a valid complete entry; three beeps indicate an error or that you are leaving the programming mode.
D. Quick Programming Features
Memory
Location
Enter Digits
- then -
+
+
+
+
To Program the SRC-1 to...
...operate the doorstrike for 2 seconds
...activate the doorstrike when touch tones “
“ are detected
...activate the doorstrike when touch tone “6” is detected
...allow the entry device to dial through the unit
Enter Digits:
0 2 # 4 0
# 4 1
6 # 4 1
1
E. Programming Examples
Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries
assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.
DOD# 176
Printed in the U.S.A.
P
P
r
r
o
o
d
d
u
u
c
c
t
t
S
S
u
u
p
p
p
p
o
o
r
r
t
t
L
L
i
i
n
n
e
e
.
.
.
.
.
.
7
7
1
1
5
5
.
.
3
3
8
8
6
6
.
.
8
8
6
6
6
6
6
6
F
F
a
a
x
x
B
B
a
a
c
c
k
k
L
L
i
i
n
n
e
e
.
.
.
.
.
.
7
7
1
1
5
5
.
.
3
3
8
8
6
6
.
.
4
4
3
3
4
4
5
5
ZF302690 Rev A
O
O
p
p
e
e
r
r
a
a
t
t
i
i
o
o
n
n
This mode is used when the entry device needs to dial to connect to the secure phone. Going off-hook with the entry device starts
a 5 second timer that is restarted by any touch tone until it has timed out. After 5 seconds without any touch tones, the next touch
tone will cause the unit to disconnect the entry device and listen for the relay activation code from the line in side.
Special Cases:
If '
' is the first digit dialed after going off-hook, the unit will bypass the timer, disconnect the entry device, and listen for the secu-
rity code or a second '
'. If '
' is dialed after any other digits and the relay activation code is set to '
', the unit will bypass the timer, disconnect
the entry device, and listen for the second '
'. If '#' is the first digit dialed after going off-hook and keyless entry codes are enabled (
3
), the unit
will bypass the timer, disconnect the line in side, and listen for a keyless entry code from the entry device.
A.
1 Mode (Dialing Allowed)
This mode is used when the entry device doesn't need to dial to connect to the secure phone. After going off-hook, the first touch
tone will cause the unit to disconnect the entry device and listen for the relay activation code from the line in side.
Special Cases:
If '
' is the first digit dialed after going off-hook, the unit will disconnect the entry device and listen for the security code or a sec-
ond '
'. If '#' is the first digit dialed after going off-hook and keyless entry codes are enabled (
3
), the unit will disconnect the line in side and listen
for a keyless entry code from the entry device.
B.
2 Mode (Dialing Disabled)
The
SRC-1
can be programmed with up to 32 keyless entry codes. This feature allows a user to activate the relay by entering a
pre-programmed code on the entry phone keypad. Each keyless entry code can contain 1-6 digits (0-9 or
) and is programmed
by entering the digits to any of the locations
#00 - #31
. To clear a location, enter # + the position number without any preceding
numbers.
C. Keyless Entry Codes
A momentary closure across terminals 5 and 6 will activate the relay for the programmed time. If the closure is longer than the pro-
grammed relay activation time, the relay will remain activated until the closure is released.
C. Trigger Input