Disassembly
24
©2012 Viking Preferred Service
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Access Control Board Assembly
The Control board is located below the oven
cavity. Access is required in order to perform many
troubleshooting procedures.
1. Remove screws and lift kick plate from keyhole
screws.
2. Remove keyhole screws and lower access grill from
range.
3. Remove screws and slide control panel assembly
from range.
Note:
During installation, make sure the tabs on the
control panel are aligned with the slots on the
range.
4. Reverse procedure for installation.
Control and Power Board Removal
The Control Board and the Power Board are located
below the oven cavity.
1. Access Control Board (see Access Control Board
Assembly).
2. Mark and disconnect all connectors from control
board, power board, and capacitors.
3. Place control board panel assembly on suitable work
surface.
4. Remove screws and control board from lower
mounting plate.
5. Reverse procedure for installation.