Locate water filter door. The door is located under 

the Adjustable Cold Zone™ handle.

Push upper left corner of door to release latch 

and pull door downward.

Insert filter cartridge into circular opening in filter
housing. Rotate clockwise gently until filter stops.

Close water filter door.

Flush 3 gallons through filter before use (flush

approximately 3 minutes). If water spurts occur,

continue to run water until water runs steady.

Additional flushing may be required in areas with poor

quality water.

NOTE:

Allow 1-2 minute delay in water dispersal to

allow internal water tank to fill.

24

2

1

25

1

3

2

26

27

   Water Filter Installation 

(Side-by-Side with Dispenser)

Water Filter System Specification and Performance Data

This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration of less than or
equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.* (100% safety factors
built-in for unmetered usage for health claims only.)

*Based on the use of Cryptosporidium parvum oocysts

Operating Specifications

Capacity:  

Certified for up to 750 gallons (2,838 L); up to nine months

Pressure Requirement:  

20 - 120 psi (1.4 - 8.2 bar)

Temperature: 33-100

o

F (0.6 - 37.8

o

C)

Flow rate:

0.78 gpm (2.9 l/min.)

Check for compliance with the state and local laws and regulations.

Note: 

While the testing was performed under standard laboratory conditions, actual performance may vary.  

Must be installed and operated in accordance with manufacturer’s recommended procedures and guidelines.
Installation instructions, parts and service availability, and standard warranty are included with the product when
shipped. This drinking water system must be maintained according to manufacturer’s instruction, including
replacement of filter cartridges.

Manufactured by:

3M Purification Inc.
400 Research
Parkway
Meriden, CT  06770

System tested and certified by NSF International
against Standard 42 for the reduction of chlorine
taste and odor, particulate Class I and Standard 53
for the reduction of Lead, Lindane, Atrazine, Mercury,
Toxaphene, Cyst, Turbidity, and Abestos.

Contaminant

Reduction

Average

Influent

NSF Specified

Challenge

Concentration

Avg %

Reduction

Average

Product Water

Concentrtation

Max Permissible

Product Water

Concentration 

NSF

Reduction

Requirements

NSF Test

Report

Chlorine Taste and 
Odor

2.0 mg/L

2.0 mg/L + 10%

97.5%

0.05 mg/L

N/A

> 50%

J-00056501

Nominal Particulate
Class I, >0.5 to < 

1.0 µm

13,666,667

pts/mL

At least 10,000

particles/mL

98.9%

143,333 pts/mL

N/A

> 85%

J-00056506

Asbestos

96 MF/L

10

7

to 10

8

fibers/L;

fibers greater than

10µm in length

>99%

<1 MF/L

N/A

> 99%

J-00056511

Atrazine

0.010 mg/L 0.009 mg/L + 10%

89.3%

0.001 mg/L

0.003 mg/L

N/A

J-00056512

Cyst*

122,500

cysts/L

Minimum 50,000

cysts/L

99.99%

1 cyst/L

N/A

> 99.95%

J-00056513

Lead @ pH 6.5

0.153 mg/L 0.15 mg/L + 10%

99.3%

0.001 mg/L

0.010 mg/L

N/A

J-00056515

Lead @ pH 8.5

0.150 mg/L 0.15 mg/L + 10%

99.3%

0.001 mg/L

0.010 mg/L

N/A

J-00058784

Lindane

0.002 mg/L 0.002 mg/L + 10%

97.8%

0.00004 mg/L

0.0002 mg/L

N/A

J-00058969

Mercury @ pH 6.5

0.006 mg/L 0.006 mg/L + 10%

95.0%

0.0003 mg/L

0.002 mg/L

N/A

J-00058785

Mercury @ pH 8.5

0.006 mg/L 0.006 mg/L + 10%

88%

0.0007 mg/L

0.002 mg/L

N/A

J-00058783

Toxaphene

0.015 mg/L 0.015 mg/L + 10%

93.2%

0.001 mg/L

0.003 mg/L

N/A

J-00056531

Turbidity

10.8 NTU

11 + 1 NTU

98.7%

0.153 NTU

0.5 NTU

N/A

J-00058972

Содержание Quiet Cool VCSB5421

Страница 1: ...reenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit the Viking Web site at vikingrange com F20842A EN 041513 Viking Installation Guide Side By Side Bottom...

Страница 2: ...___ 18 Cabinet Information Professional with flush mount trim _______________________________ 20 Custom Side Panel Dimensions Professional _________________________________________ 22 Custom Side Pane...

Страница 3: ...ood screws longer screws may be required 1 Saddle valve do not use self piercing feature of the valve assure that floor will support unit door panels and contents approximately 1200 pounds 540 kg prov...

Страница 4: ...height from bottom 82 3 4 210 2 cm min to 84 1 16 213 5 cm max Overall depth from rear To front edge of side trim 22 3 16 56 4 cm To front of top grille 24 61 0 cm To front of handle endcap 26 1 2 67...

Страница 5: ...h 48 121 9 cm Overall height from bottom 82 3 4 210 2 cm min to 84 1 16 213 5 cm max Overall depth from rear To front edge of side trim 23 3 8 59 4 cm To front of top grille 24 61 0 cm To front of han...

Страница 6: ...0 1 2 204 6 cm max to bottom of anti tip board 35 88 9 cm 3 1 2 8 9 cm 3 7 6 cm 35 88 9 cm 3 1 2 8 9 cm 1 5 3 8 cm Anti Tip Dimensions Side By Side 11 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min ant...

Страница 7: ...1 2 204 6 cm max to bottom of anti tip board 41 104 1 cm 3 1 2 8 9 cm 3 7 6 cm 41 104 1 cm 3 1 2 8 9 cm 1 1 2 3 8 cm Anti Tip Dimensions Side By Side 13 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min a...

Страница 8: ...n to 84 1 16 213 5 cm max Overall depth from rear To front edge of side trim 23 3 8 59 4 cm To front of top grille 24 61 0 cm To front of handle endcap 26 1 2 67 3 cm Cutout wdth 36 91 4 cm Cutout hei...

Страница 9: ...1 2 204 6 cm max to bottom of anti tip board 29 1 2 74 9 cm 3 1 2 8 9 cm 3 7 6 cm 29 1 2 74 9 cm 3 1 2 8 9 cm 1 5 3 8 cm Anti Tip Dimensions Bottom Mount 17 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm...

Страница 10: ...cm Space if 24 standard cabinet depth is used Door 24 61 0 cm Standard Cabinet Depth Wall 3 4 1 9 cm Full End Panel 1 3 4 4 4 cm Offset Partial Overlay Cabinet Door Cabinet Information Professional 18...

Страница 11: ...4 1 9 cm Full End Panel 3 4 1 9 cm space if 24 61 0 cm standard cabinet depth is used Flush Cabinet Door Door Wall 3 4 1 9 cm Full End Panel 1 2 5 cm space if 25 63 5 cm cabinet depth is used Flush 2...

Страница 12: ...Flush Mount Trim 23 3 4 1 9 cm End panel 5 32 0 4 cm 3 16 0 5 cm Back filler panel 22 7 16 57 0 cm 22 7 16 57 0 cm 22 1 4 61 0 cm 6 15 2 cm Optional kickplate Notch dimensions determined by cabinets...

Страница 13: ...ally mounted 2X4s included bolted to two wall studs The 2X4 board bolt heads must be flush with 2X4 to prevent obstruction Remove anything attached to rear or side walls that can obstruct unit install...

Страница 14: ...p 3 Cut carton rear approximately 1 4 0 6 cm to 1 2 5 cm from right corner with a utility knife extended 1 4 0 6 cm 4 Remove carton and exterior packaging Save cardboard shipping material to protect f...

Страница 15: ...off Connect supply tube to water valve using a 1 2 wrench NOTE DO NOT overtighten 28 Remove four side screws and remove unit top Loosen the four hinge screws Adjust door Retighten four hinge screws Re...

Страница 16: ...crew and place in 90 or 120 position 30 Lift unit off rollers to desired height and level unit using a 5 16 head wrench NOTE DO NOT use an electric device Overtightening can cause damage Attach positi...

Страница 17: ...edures and guidelines Installation instructions parts and service availability and standard warranty are included with the product when shipped This drinking water system must be maintained according...

Страница 18: ...nd verify unit is secure Position unit in cutout level at desired height and secure unit Plug in unit and verify operation Connect water supply if applicable Verify icemaker fill tube is properly inse...

Страница 19: ...to obtain the name of an authorized service agency or if you continue to have service problems contact Viking Range Corporation at 1 888 845 4641 or write to VIKING RANGE LLC PREFERRED SERVICE 111 Fr...

Страница 20: ...39 38...

Отзывы: