ACTIVATE
CONTROLS
FAST
COOL
ACTIVATE
CONTROLS
MAX
FRZ
Operation
©2012 Viking Preferred Service
7
and releasing the "MAX FRZ" tab.
This causes the control to
temporarily (factory setting is 6
hours) change the current freezer set point
to -5
o
F. This set point temperature is not
adjustable and is programmed from factory.
The time duration is adjustable in Program
Mode B, range is 1 to 20 hours in 1 hour
increments.
When MAX FRZ is selected, the display
illuminates "MAX FRZ" as shown above. The
temperature display will move towards that
set point temperature (- 5
o
F) as the unit pulls
down. The down arrow will flash 1 sec on and
1 sec off until cabinet temperature reaches
set point temperature.
Max Frz will terminate at the conclusion
of the time duration or if another mode is
selected, or if the temperature is manually
changed by pressing "HIGHER or LOWER"
tabs. Max Frz can also be terminated by
again pressing and releasing "MAX FRZ".
The conclusion or termination of this mode is
confirmed by "MAX FRZ" extinguishing from
display.
Max Frz is enabled by pressing
and releasing the "ACTIVATE
CONTROLS" pad and then Pressing
MAX FRZ
When "FAST COOL" is selected by pressing
the pad, "FAST COOL" is illuminated on the
display as shown in illustration above. The
down arrow will flash 1 sec on and 1 sec off
until cabinet temperature reaches set point
temperature.
Fast Cool will terminate after the time
duration has expired or if another mode is
selected or if temperature is increased or
decreased by pressing "HIGHER or LOWER"
tabs. Fast Cool can be cancelled by pressing
"FAST COOL" again, the Fast Cool will
extinguish on the display.
Fast Cool
Fast Cool is enabled by pressing
and releasing the "ACTIVATE
CONTROLS" pad and then
pressing and releasing the "FAST
COOL"pad.
This causes the control to
temporarily (predetermined time, factory
default is 2 hours) replace the freezer setpoint
to Max Frz temperature (factory default -5
o
F)
and also the refrigerator setpoint to Max Ref
temperature (factory default 33
o
F).
Max Frz and Max Ref time duration is
adjustable in Program Mode B, range is 1 to
20 hours in 1 hour increments.
The only temperature speed used during this
mode of operation is high speed (115HZ).
Содержание Quiet Cool VCFB5301
Страница 48: ...Schematic 48 2012 Viking Preferred Service 30 All Freezer Schematic Upper Section...
Страница 49: ...Schematic 2012 Viking Preferred Service 49 30 All Freezer Schematic Lower Section...
Страница 50: ...Schematic 50 2012 Viking Preferred Service 36 All Freezer Schematic Upper Section...
Страница 51: ...Schematic 2012 Viking Preferred Service 51 36 All Freezer Schematic Lower Section...
Страница 52: ...Wiring Diagrams 52 2012 Viking Preferred Service UPPER SECTION WIRING 30...
Страница 53: ...Wiring Diagrams 2012 Viking Preferred Service 53 LOWER SECTION WIRING 30...
Страница 54: ...Wiring Diagrams 54 2012 Viking Preferred Service UPPER SECTION WIRING 36...
Страница 55: ...Wiring Diagrams 2012 Viking Preferred Service 55 LOWER SECTION WIRING 36...