background image

P

P

r

r

a

a

c

c

t

t

i

i

c

c

e

e

T

T

E

E

L

L

E

E

C

C

O

O

M

M

S

S

O

O

L

L

U

U

T

T

I

I

O

O

N

N

S

S

F

F

O

O

R

R

T

T

H

H

E

E

2

2

1

1

S

S

T

T

C

C

E

E

N

N

T

T

U

U

R

R

Y

Y

TECHNICAL

TECHNICAL

The 

LC-6

Line Concentrator eliminates the monthly

charges for a dedicated line to each elevator. The 

LC-6

is

designed to be used with the Viking 

1600A Series

Elevator

Phones. Up to six of these emergency phones can commu-
nicate with authorized personnel on 3 other phones within a
building, or add a telephone line to allow communication
outside the building. A call initiated by an emergency phone
can dial internally, externally, or both. Any other phones that
are activated will be bridged with authorized personnel, thus
fulfilling ASME A17.1 requirements. 

All telephone line inbound calls are answered by the 

LC-6

.

A touch tone command will route the call to any of the

phone ports. If no command is detected within 4 seconds, the call will be routed to the last emergency
phone that was used. This allows emergency personnel to easily call back to the same phone.

Connections include a Fire Floor phone, a Machine Room phone and a Lobby phone. An output is also
provided for driving up to three Viking 

LM-24D

displays to show status of all ports.

Per ASME A17.1 requirements, the 

LC-6

can verify the operability of the telephone line on a daily basis

and with the optional Viking model 

LV-1K

line verification alarm panel, can display an “Elevator

Communications Failure”. 

Note: 

Per ASME A17.1 requirements, the 

LC-6

must be used with a battery

backup (UPS) capable of keeping the 

LC-6

running for up to 4 hours. 

Concentrate up to Six Emergency Phones and

Comply with ASME A17.1 Elevator Code

h

h

t

t

t

t

p

p

:

:

/

/

/

/

w

w

w

w

w

w

.

.

v

v

i

i

k

k

i

i

n

n

g

g

e

e

l

l

e

e

c

c

t

t

r

r

o

o

n

n

i

i

c

c

s

s

.

.

c

c

o

o

m

m

•  Connects up to (6) emergency phones 

•  Communicate with local and remote authorized 

personnel  

•  Automatic answering of inbound calls

•  Touch Tone transferring

•  Separate Fire Floor phone port

•  Machine Room phone and Lobby phone ports

•  Accommodates the re-dialing feature of the 

Viking 

1600A Series

phones

•  Programmable daily line verification check

Power: 

120V AC/13.8V AC UL listed adapter provided

Dimensions:

210 mm x 159 mm x 45 mm (8.25” x 6.25” x 1.75”)

Shipping Weight:

1.5 kg (3.2 lbs.)

Environmental:

0 C to 32 C (32 F to 90 F) with 5% to 95% non-

condensing humidity

Maximum LM-24D Wire Length:

152m (500 ft) with #24 gauge

wire

Maximum LV-1K Wire Length:

610m (2000 ft) with #24 gauge

wire

Battery Backup: 

Greater than 4 hours when using TRIPP-LITE

model INTERNET550U (not included)

Connections:

25 screw terminal block positions

F

F

e

e

a

a

t

t

u

u

r

r

e

e

s

s

S

S

p

p

e

e

c

c

i

i

f

f

i

i

c

c

a

a

t

t

i

i

o

o

n

n

s

s

•  Elevator phones

•  Emergency phones

•  Area-of-Refuge phones

•  E-30 courtesy phones

A

A

p

p

p

p

l

l

i

i

c

c

a

a

t

t

i

i

o

o

n

n

s

s

LC-6

LC-6

6 Port Line

Concentrator for

Emergency Phones

September 28, 2012

P

P

h

h

o

o

n

n

e

e

.

.

.

.

.

.

7

7

1

1

5

5

.

.

3

3

8

8

6

6

.

.

8

8

8

8

6

6

1

1

m

m

a

a

i

i

l

l

@

@

v

v

i

i

k

k

i

i

n

n

g

g

e

e

l

l

e

e

c

c

t

t

r

r

o

o

n

n

i

i

c

c

s

s

.

.

c

c

o

o

m

m

Содержание LC--6

Страница 1: ...ation alarm panel can display an Elevator Communications Failure Note Per ASME A17 1 requirements the LC 6 must be used with a battery backup UPS capable of keeping the LC 6 running for up to 4 hours...

Страница 2: ...t be provided to the telephone company The REN is used to determine the number of devices that may be connected to a telephone line Excessive REN s on a telephone line may result in the devices not ri...

Страница 3: ...s emergency phones can be installed to internally communicate with a Fire Floor phone a Machine Room phone and a Lobby phone through the LC 6 The Lobby phone connection is not a separate port but is s...

Страница 4: ...When the LC 6 answers wait for the beep then enter Q followed by the 6 digit security code factory set to 845464 see Programming section B A double beep should then be heard indicating you have entere...

Страница 5: ...the number of times the LC 6 will ring the called device when a transfer is initiated Entering a 0 count will disable the ring counter altogether and the port will continue to ring until answered or t...

Страница 6: ...econds of silence so the LC 6 knows it is a trans fer command and not part of a dialing string Note The internal line does not supply dial tone 2 DIP Switch 2 Line Verification Test When this switch i...

Страница 7: ...a single touch tone 7 or 8 respectively D Fire Floor Phone When the Fire Floor phone goes off hook the LC 6 will send a single beep The user can then enter a touch tone 1 to 6 to call emergency phone...

Страница 8: ...cation fault is detected The LV 1K line verification alarm panel can service a group of elevators controlled by a Fire Recall switch and must be located in the vicinity of that switch and be visible t...

Отзывы: