VIKING TECHNICAL SUPPORT 1.800.908.0884
2 0
Open Limit
Close Limit
LIMITS SETUP
STEP 1
Connect the Motor Harness to the:
“OPEN LEFT” connector if the
gate opens to the left.
“OPEN RIGHT” connector if the
gate opens to the right.
STEP 2
Move the gate at the desired open
position then press the “Open Limit”
button and hold it down until the LED
stops flashing.
STEP 3
Move the gate at the desired close
position then press the “Close Limit”
button and hold it down until the LED
stops flashing.
Tip:
The gate can be moved electronically with the “Open”, “Stop” and “Close” buttons
on the Control Board or manually by following the instructions on page 11.
“Close Limit” LED
flashes if the close
limit is not set.
“Open Limit” LED
flashes if the open
limit is not set.
!
IMPORTANT:
In the event of a complete power failure, including battery backup, the
limits positions will have been cleared and will need to be reset by following the steps
below..