11

2.  Unit Name

3.  Mute Current  / Next Alarm

4.  Phone Firmware

5.  IP Firmware

Up to a 31 character phone name can be assigned to the 

K-1900-6/7-IP

being programmed. Often times the building

name and entrance location near the unit are used for the name.

A network failure alarm will be indicated by flashing the ”SIP Alarm LED” (located on PCB) and providing 3 beeps every
30 seconds in the handset of the 

K-1900-6/7-IP

. A network failure indicates the unit is not registered to the SIP server

or there is a communication failure with the gateway. The three beeps can be muted by clicking on the “Mute Current /
Next Alarm”.   

If new 

K-1900-6/7-IP

firmware is available, after opening the programming software a pop window will  ask if you would

like to update firmware. Another way to update is accomplished by clicking the phone firmware “Update” button. You
can then browse to the folder that contains the HEX file for updating the unit’s firmware. This method is typically only
used when Viking Technical Support has sent you updated firmware.

If new 

K-1900-6/7-IP

firmware is available, after opening the programming software a pop window will  ask  if you would

like to update firmware. Another way to update is accomplished by clicking the IP firmware “Update” button. You can
then browse to the folder that contains the PIP file for updating the unit’s IP firmware. This method is typically only used
when Viking Technical Support has sent you updated IP firmware.

6.  Import/Export

The Import/Export feature is useful for backing up all the 

K-1900-6/7-IP’s

programming or for importing programming

when installing multiple units with a majority of the same programming.

Clicking on the “Clear Phone settings” button in programming will reset all of the Programming Features back to their
factory default settings. 

Note: 

This    command will not change or reset your IP settings or phone numbers.

7. Clear Phone Settings

9. Diagnostics

The Diagnostics section in the 

K-1900-6/7-IP

Programming can be used to test the status & functionality of the relay.

Clicking on the “Clear IP Settings” will reset IP setting only. 

Note: 

This    command will not change or reset your phone

settings or phone numbers.

8. Clear IP Settings

The phone number programmed in the first location is the number that is dialed when the ”

K-1900-6/7-IP

” goes off

hook.  Additional numbers will be dialed when there is no answer or a busy signal is detected. The 

K-1900-6/7-IP

phone

is factory set with no phone numbers programmed. These phone numbers can be up to 20 digits.

1.  Phone Numbers (1-5)

Programming Features

Содержание K-1900-7-EWP

Страница 1: ...del Phone only 5 0 x 10 0 x 5 1 127mm x 254mm x 130mm Including rough in box 5 0 x 10 0 x 5 4 127mm x 254mm x 137mm Shipping Weight for K 1900 6 IP 2 0 lbs 0 9 kg Shipping Weight for K 1900 7 IP 3 7 l...

Страница 2: ...tform V6 2 9 or earlier Avaya IP Office Platform BlueBox Brekeke Cisco Unified Communications Manager CUCM Cisco Unified Communications Manager Express CUCME Elastix epygi QX200 4 Freeswitch Grandstre...

Страница 3: ...nsport Protocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A co...

Страница 4: ...designed for insulation displacement on 19 26 gauge wire with a maximum insulation of 0 082 inches Front View of the K 1900 7 IP VoIP Panel Phone Condensation Drain Hole Mounting Screws 8 6 32 x 3 4...

Страница 5: ...g the K 1900 6 IP B Installing the K 1900 7 IP To install the K 1900 7 IP panel phone attach the panel to a standard double gang electrical box using the provided screws or use the optional VE 5x10 or...

Страница 6: ...IP Entry Phone 4 K 1900 6 IP Entry Phone 3 N O COM 2 Gel Filled Butt Connectors included Doorstrike Magnetic Lock 120V AC Door near Entry Phone 2 N O COM Relay 4 Output Contacts 5A 30VDC 250VAC max C...

Страница 7: ...oIP Phone System SIP VoIP PBX or PC with SIP Server Software 100m 328 ft maximum Viking supplies Customer s Responsibility Internet 10 100 Mbps Maximum Viking K 1900 6 7 IP VoIP Phone Note A PoE exten...

Страница 8: ...ame MAC addresses must be used to identify each phone When finished programming click on the Disconnect button at the bottom Closing the program will also automatically disconnect the unit With the un...

Страница 9: ...it Name field When finished click on the Apply button to send the IP settings to the connected unit See Examples 1 and 2 of the required fields below E Manually Resetting All Network Parameters to Fac...

Страница 10: ...Mode Ring Ring Flash factory set to Door Strike 14 13 Relay Activation Command 1 or 2 digits factory set to QQ Relay Mode must be set to Door Strike 15 13 Relay Activation Time 0 5 99 sec factory set...

Страница 11: ...her way to update is accomplished by clicking the IP firmware Update button You can then browse to the folder that contains the PIP file for updating the unit s IP firmware This method is typically on...

Страница 12: ...ing pattern selected in Ring Cadence The call can then be answered by taking the handset off hook Ring High In the High mode the phone will output a slightly louder higher pitched ring signal out of t...

Страница 13: ...ory setting is 5 seconds THis also controls the length of relay closure in Door Bell Mode 16 Relay Activation Time Doorstrike Mode When programmed for Doorstrike Mode the relay is intended for door st...

Страница 14: ...you are making an outbound call through your VoIP phone system and are relying on In Band analog audio for ringback or busy detection The factory default is Enabled 19 In Band Audio Call Progress The...

Страница 15: ...nd you can now enter the Remote Access Operation Commands below The relay must be set to Door Strike Mode to be controlled by these commands Note Latching commands must be enabled in programming Troub...

Страница 16: ...m panel The user can customize the clear coated aluminum panel to mount an PRX 1 card reader PRX 2 keypad or switch The kits come complete with box gasket panel and screws Model numbers that end with...

Страница 17: ...r SIP VoIP phone systems with PoE The unit can be programmed from any PC on the same LAN or remotely using a Static IP Address The K 1900 8 IP phone can dial up to 250 programmable numbers and another...

Страница 18: ...to a PO Box 4 RA number on carton In large printing write the R A number on the outside of each carton being returned RETURNING PRODUCT FOR EXCHANGE The following procedure is for equipment that has...

Отзывы: