Viking FDWB301R Скачать руководство пользователя страница 3

4

IMPORTANT–Please Read and Follow!

WARNING

TIP OVER HAZARD

Appliance is top heavy

and tips easily when

not completely

installed. Keep doors

closed until appliance

is completely installed

and secured per installation instructions.

Use two or more people to move and

install appliance. Failure to do so can

result in death or serious injury.

WARNING

ELECTRICAL SHOCK 

HAZARD

Disconnect power or turn 

power disconnect switch to 

OFF position before removing 

top grille. Failure to do so can 

result in death or electrical shock.

Most of the unit’s weight is at the top. Extra care is needed when moving the unit to prevent

tipping. Use cardboard shipping material or plywood under unit until it is installed in the 

operating position to protect floor surface.

5

IMPORTANT–Please Read and Follow!

A GFI 

shall be used if required by NFPA-70 (National Electric Code), federal/state/local

laws, or local ordinances.

• The required use of a GFI is normally related to the location of a receptacle with respect to

any significant sources of water or moisture.

• Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which

are not installed properly or do not meet the requirements below.

If the use of a GFI is required

, it should be:

• Of the receptacle type (breaker type or portable type NOT recommended)

• Used with permanent wiring only (temporary or portable wiring NOT recommended)

• On a dedicated circuit (no other receptacles, switches or loads in the circuit)

• Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT

recommended)

• Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard

• In good condition and free from any loose-fitting gaskets (if applicable in outdoor situations)

• Protected from moisture (water, steam, high humidity) as much as reasonably possible

Содержание FDWB301R

Страница 1: ...od Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com UL C UL Viking Installation Guide Professional Custom Panel Bu...

Страница 2: ...___ 31 Service Registration_______________________________________________________________ 32 3 IMPORTANT Please Read and Follow Make sure that incoming voltage is the same as unit rating An electric...

Страница 3: ...used if required by NFPA 70 National Electric Code federal state local laws or local ordinances The required use of a GFI is normally related to the location of a receptacle with respect to any signi...

Страница 4: ...y 150 bottles Approximate shipping weight 560 lbs 252 kg 82 7 8 210 5 cm min to 84 1 16 213 5 cm max 29 73 7cm 70 177 5 cm 9 5 16 23 6 cm 22 3 16 56 4 cm Standard Mount 23 13 16 60 5 cm Flush Mount 24...

Страница 5: ...They can be installed in standard 24 61 0 cm deep openings The door faces and top grille will protrude 3 4 1 9 cm into the room 2 x 4 Mounting Board 1 1 2 3 8 cm x 3 1 2 8 9 cm Attached to anti tip mo...

Страница 6: ...odels fit semi flush in standard 24 61 0 cm deep cabinet openings The door face protrudes 2 1 16 5 2 cm from the cabinet face The handle protrudes an additional 2 1 2 6 4 cm into the room TOP VIEW Cab...

Страница 7: ...rofessional with Flush Mount Trim Professional models with Flush Mount Trim fit flush in standard 24 61 0 cm deep cabinet openings with no protrusion into the room except 2 1 2 6 3 cm handle depth Doo...

Страница 8: ...d cabinet depth is used 24 61 0 cm standard cabinet depth TOP VIEW 15 Cabinet Information Custom Panel Custom Panel models 3 4 1 9 cm thick panels and custom handles locally supplied fit flush in 25 6...

Страница 9: ...sed 24 61 0 cm standard cabinet depth Cabinet front 25 63 5 cm 3 4 1 9 cm full end panel TOP VIEW Cabinet Information Custom Panel Custom Panel models can be installed in standard 24 61 0 cm deep open...

Страница 10: ...t enclosure height TOP VIEW Custom Side Panel Dimensions Custom Panel Professional with Flush Mount Trim Z Bracket 1 2 5 cm 1 4 0 6 cm 3 4 1 9 cm End panel 21 3 4 55 2 cm 21 3 4 55 2 cm 24 61 0 cm Opt...

Страница 11: ...anel Model Panels must not weigh more than 50 pounds per door Pre drill the holes in the panel per the panel dimension instructions See Panel Dimensions for proper hole locations Place the panel onto...

Страница 12: ...rack Remove the wood facing Follow the dimensions below to cut wood facing out of alternative woods Back of facing 23 7 8 60 6 cm 4X 3 32 0 1 cm dia 1 2 1 27 cm deep 1 15 16 4 9 cm 1 7 16 3 7 cm 6 11...

Страница 13: ...ng boards may be required if the unit does not touch the back wall of the enclosure To prevent unit from tipping forward it must be secured in place with a solid soffit or wood block ELECTRICAL SHOCK...

Страница 14: ...ffit OPTION 2 If a solid soffit is not available or soffit is more than 1 2 5 cm above wine cellar center wood boards on rear wall 1 4 0 6 cm maximum above wine cellar Attach wood boards to wall studs...

Страница 15: ...ric driving device Overtightening can cause damage 5 Align wine cellar with sides of cabinets by adjusting leveling legs Rotate leveling legs until firmly in place against floor 6 To secure wine cella...

Страница 16: ...location of the door 3 When proper adjustment is reached align shim with door stop pin holes and replace door stop pin Firmly tighten pin in place 90 stop farthest from unit 120 stop closest to unit...

Страница 17: ...ellar are located on the right wall in the bottom zone Record the information indicated below You will need it if service is ever required Model number ________________________________________________...

Страница 18: ...35 34...

Отзывы: