Viking FDWB301R Скачать руководство пользователя страница 14

27

26

Back side of wine cellar

Red, white, and black

wiring*

*Black  = common

Red  = normally closed
White = normally open

Home Security System Connection

NOTE: 

Contact a qualified electrician or authorized agent from alarm company to connect your
home security system to the wine cellar.

Home security system connection must be hooked up before the unit is installed.
1. Remove the four mounting screws attaching the unit compartment cover to the cabinet. (2 

per side)

2. Remove the grille louver assembly to access the black safety grille.
3. Turn power off.
4. Remove the four screws that attach the top grille assembly to the mounting brackets.
5. Remove the 3 screws at the right side of the unit that attach the safety grille to the 

compartment cover.

6. Choose the desired switching position and connect according to alarm system requirements.  
7. Replace the unit compartment cover.

The home security system will be activated if temperatures in the wine cellar fluctuate outside of
the set point by 5° for and extended time period.

Securing Your Wine Cellar 

(3 options)

OPTION 1

If a solid soffit is 1” (2.5 cm) or less above the wine cellar, anti-tip boards are not required. To
secure the wine cellar raise unit until compartment is firmly seated under the soffit.

OPTION 2

If a solid soffit is not available or soffit is more than 1” (2.5 cm) above wine cellar, center wood
boards on rear wall 1/4” (0.6 cm) maximum above wine cellar. Attach wood boards to wall studs
with six of the provided wood screws, making sure that screws are engaged in wall studs 1-1/2”
(3.8 cm) minimum and that boards extend 2” (5.0 cm) minimum over the top rear of wine cellar
compressor cover. To secure the wine cellar, raise unit until compartment is firmly seated under
the anti-tip board.

OPTION 3  

Position the wood block over the unit and secure it to wall studs using eight of the provided
wood screws and “L” brackets. Make sure screws extend a minimum of 1” (2.5 cm) into each of
the two wall studs. The wood block must extend a minimum of 3” (7.6 cm) over the unit. To
secure the wine cellar, raise unit until compartment is firmly seated under the anti-tip boards.

WARNING

ELECTRICAL SHOCK HAZARD

Disconnect power at breaker or turn power

disconnect switch to OFF position before

performing any installation procedure. Failure

to do so can result in death or electrical shock.

Solid Soffit

1”

(2.5 cm)

or less

Rear

Wall

OPTION 1

1/4” (0.6 cm)

maximum

2”

(5.0 cm)

minimum

Two 2 x 4

boards

attached to

wall with six

wood screws

(minimum)

OPTION 2

1/4” (0.6 cm)

maximum

3”

(7.6 cm)

minimum

“L” bracket

with (4) screws

on each end.

(1) 2x4

attached to

both “L”

brackets -

minimum of

1” (2.5 cm) screws.

Screws extend

minimum of

1” (2.5 cm) into

each wall stud.

OPTION 3

Содержание FDWB301R

Страница 1: ...od Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com UL C UL Viking Installation Guide Professional Custom Panel Bu...

Страница 2: ...___ 31 Service Registration_______________________________________________________________ 32 3 IMPORTANT Please Read and Follow Make sure that incoming voltage is the same as unit rating An electric...

Страница 3: ...used if required by NFPA 70 National Electric Code federal state local laws or local ordinances The required use of a GFI is normally related to the location of a receptacle with respect to any signi...

Страница 4: ...y 150 bottles Approximate shipping weight 560 lbs 252 kg 82 7 8 210 5 cm min to 84 1 16 213 5 cm max 29 73 7cm 70 177 5 cm 9 5 16 23 6 cm 22 3 16 56 4 cm Standard Mount 23 13 16 60 5 cm Flush Mount 24...

Страница 5: ...They can be installed in standard 24 61 0 cm deep openings The door faces and top grille will protrude 3 4 1 9 cm into the room 2 x 4 Mounting Board 1 1 2 3 8 cm x 3 1 2 8 9 cm Attached to anti tip mo...

Страница 6: ...odels fit semi flush in standard 24 61 0 cm deep cabinet openings The door face protrudes 2 1 16 5 2 cm from the cabinet face The handle protrudes an additional 2 1 2 6 4 cm into the room TOP VIEW Cab...

Страница 7: ...rofessional with Flush Mount Trim Professional models with Flush Mount Trim fit flush in standard 24 61 0 cm deep cabinet openings with no protrusion into the room except 2 1 2 6 3 cm handle depth Doo...

Страница 8: ...d cabinet depth is used 24 61 0 cm standard cabinet depth TOP VIEW 15 Cabinet Information Custom Panel Custom Panel models 3 4 1 9 cm thick panels and custom handles locally supplied fit flush in 25 6...

Страница 9: ...sed 24 61 0 cm standard cabinet depth Cabinet front 25 63 5 cm 3 4 1 9 cm full end panel TOP VIEW Cabinet Information Custom Panel Custom Panel models can be installed in standard 24 61 0 cm deep open...

Страница 10: ...t enclosure height TOP VIEW Custom Side Panel Dimensions Custom Panel Professional with Flush Mount Trim Z Bracket 1 2 5 cm 1 4 0 6 cm 3 4 1 9 cm End panel 21 3 4 55 2 cm 21 3 4 55 2 cm 24 61 0 cm Opt...

Страница 11: ...anel Model Panels must not weigh more than 50 pounds per door Pre drill the holes in the panel per the panel dimension instructions See Panel Dimensions for proper hole locations Place the panel onto...

Страница 12: ...rack Remove the wood facing Follow the dimensions below to cut wood facing out of alternative woods Back of facing 23 7 8 60 6 cm 4X 3 32 0 1 cm dia 1 2 1 27 cm deep 1 15 16 4 9 cm 1 7 16 3 7 cm 6 11...

Страница 13: ...ng boards may be required if the unit does not touch the back wall of the enclosure To prevent unit from tipping forward it must be secured in place with a solid soffit or wood block ELECTRICAL SHOCK...

Страница 14: ...ffit OPTION 2 If a solid soffit is not available or soffit is more than 1 2 5 cm above wine cellar center wood boards on rear wall 1 4 0 6 cm maximum above wine cellar Attach wood boards to wall studs...

Страница 15: ...ric driving device Overtightening can cause damage 5 Align wine cellar with sides of cabinets by adjusting leveling legs Rotate leveling legs until firmly in place against floor 6 To secure wine cella...

Страница 16: ...location of the door 3 When proper adjustment is reached align shim with door stop pin holes and replace door stop pin Firmly tighten pin in place 90 stop farthest from unit 120 stop closest to unit...

Страница 17: ...ellar are located on the right wall in the bottom zone Record the information indicated below You will need it if service is ever required Model number ________________________________________________...

Страница 18: ...35 34...

Отзывы: