background image

Viking Range, LLC

111 Front Street 

Greenwood, Mississippi 38930 USA

(662) 455-1200

For product information,

call 1-888-(845-4641)

or visit the Viking Web site at 

vikingrange.com

UL

C

UL

Viking Installation Guide

Professional/Custom Panel

Built-In Full Height Wine Cellar

F20904B EN

(043013))

Содержание FDWB301

Страница 1: ...ood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit the Viking Web site at vikingrange com UL C UL Viking Installation Guide Professional Custom Panel Built In Full Height Wine Cellar F20904B EN 043013 ...

Страница 2: ...__ 31 Service Registration_______________________________________________________________ 32 3 IMPORTANT Please Read and Follow Make sure that incoming voltage is the same as unit rating An electric rating plate specifying voltage frequency wattage amperage and phase is attached to the product To reduce the risk of fire electric shock or injury to persons installation work and electrical wiring mu...

Страница 3: ...e used if required by NFPA 70 National Electric Code federal state local laws or local ordinances The required use of a GFI is normally related to the location of a receptacle with respect to any significant sources of water or moisture Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not meet the requirements below If the us...

Страница 4: ...sage 2 3 amps Overall capacity 150 bottles Approximate shipping weight 560 lbs 252 kg 82 7 8 210 5 cm min to 84 1 16 213 5 cm max 29 73 7cm 70 177 5 cm 9 5 16 23 6 cm 22 3 16 56 4 cm Standard Mount 23 13 16 60 5 cm Flush Mount 24 1 32 61 0 cm 30 76 2 cm 27 68 6 cm NOTE Flush Mount Trim PBIRFTKSS purchased separately Description FDWB301 Overall width 30 76 2 cm Overall height from bottom 82 3 4 210...

Страница 5: ... They can be installed in standard 24 61 0 cm deep openings The door faces and top grille will protrude 3 4 1 9 cm into the room 2 x 4 Mounting Board 1 1 2 3 8 cm x 3 1 2 8 9 cm Attached to anti tip mounting bracket Note If unit is installed deeper than 24 61 0 cm then shim behind anti tip bracket thickness by the same amount to Cabinet Information Professional Professional models fit semi flush i...

Страница 6: ...models fit semi flush in standard 24 61 0 cm deep cabinet openings The door face protrudes 2 1 16 5 2 cm from the cabinet face The handle protrudes an additional 2 1 2 6 4 cm into the room TOP VIEW Cabinet Information Professional Door Wall Partial overlay cabinet door 1 13 16 4 6 cm space if 24 61 0 cm standard cabinet depth is used 3 4 1 9 cm full end panel 24 61 0 cm standard cabinet depth 2 1 ...

Страница 7: ...Professional with Flush Mount Trim Professional models with Flush Mount Trim fit flush in standard 24 61 0 cm deep cabinet openings with no protrusion into the room except 2 1 2 6 3 cm handle depth Door Flush Wall 25 63 5 cm 1 2 5 cm 3 4 1 9 cm full end panel TOP VIEW Door Flush Countertop depth Wall 1 2 5 cm space if 25 63 5 cm cabinet depth is used 24 61 0 cm standard cabinet depth Cabinet front...

Страница 8: ...rd cabinet depth is used 24 61 0 cm standard cabinet depth TOP VIEW 15 Cabinet Information Custom Panel Custom Panel models 3 4 1 9 cm thick panels and custom handles locally supplied fit flush in 25 63 5 cm deep countertop depth cabinet openings with no protrusion into room except custom handles Door Flush Wall 25 63 5 cm 1 4 0 6 cm 3 4 1 9 cm full end panel TOP VIEW ...

Страница 9: ...used 24 61 0 cm standard cabinet depth Cabinet front 25 63 5 cm 3 4 1 9 cm full end panel TOP VIEW Cabinet Information Custom Panel Custom Panel models can be installed in standard 24 61 0 cm deep openings However the door faces and top ventilation grille will protrude 3 4 1 9 cm into the room ideal for alignment with full overlay cabinet doors Door Wine cellar and cabinet door flush Wall 24 3 4 6...

Страница 10: ...et enclosure height TOP VIEW Custom Side Panel Dimensions Custom Panel Professional with Flush Mount Trim Z Bracket 1 2 5 cm 1 4 0 6 cm 3 4 1 9 cm End panel 21 3 4 55 2 cm 21 3 4 55 2 cm 24 61 0 cm Optional kickplate Notch dimensions determined by cabinets 24 61 0 cm 82 7 8 210 5 cm min to 84 1 16 213 5 cm max 82 7 8 210 5 cm min to 84 1 16 213 5 cm max Depending on how high leveling feet are rais...

Страница 11: ...Panel Model Panels must not weigh more than 50 pounds per door Pre drill the holes in the panel per the panel dimension instructions See Panel Dimensions for proper hole locations Place the panel onto the door and using 1 2 1 3 cm 8 wood screws attach the panel in 12 places 2 at the top and bottom 4 on each side Note The handle must be attached to the panel prior to installing the panel onto the d...

Страница 12: ...e rack Remove the wood facing Follow the dimensions below to cut wood facing out of alternative woods Back of facing 23 7 8 60 6 cm 4X 3 32 0 1 cm dia 1 2 1 27 cm deep 1 15 16 4 9 cm 1 7 16 3 7 cm 6 11 16 17 0 cm 2X 45 x 1 8 0 3 cm 3X R1 8 0 3 cm 1 7 16 3 7 cm 1 8 0 3 cm 1 32 0 03 cm 31 32 2 5 cm 1 8 0 3 cm 1 4 0 6 cm SIDE VIEW SHORT FACING TOP TWO ZONES Custom Wood Facing Dimensions Back of facin...

Страница 13: ...ting boards may be required if the unit does not touch the back wall of the enclosure To prevent unit from tipping forward it must be secured in place with a solid soffit or wood block ELECTRICAL SHOCK HAZARD Plug into a grounded 3 prong outlet DO NOT remove ground plug DO NOT use an adapter DO NOT use an extension cord Failure to follow these instructions could result in fire or electrical shock ...

Страница 14: ...eath or electrical shock Solid Soffit 1 2 5 cm or less Rear Wall OPTION 1 1 4 0 6 cm maximum 2 5 0 cm minimum Two 2 x 4 boards attached to wall with six wood screws minimum OPTION 2 1 4 0 6 cm maximum 3 7 6 cm minimum L bracket with 4 screws on each end 1 2x4 attached to both L brackets minimum of 1 2 5 cm screws Screws extend minimum of 1 2 5 cm into each wall stud OPTION 3 OPTION 1 If a solid so...

Страница 15: ...tric driving device Overtightening can cause damage 5 Align wine cellar with sides of cabinets by adjusting leveling legs Rotate leveling legs until firmly in place against floor 6 To secure wine cellar raise unit until compartment cover is firmly seated under the soffit or anti tip boards 7 Open door Control panel should be lit Verify the position of the power on off and showroom switch if there ...

Страница 16: ...e location of the door 3 When proper adjustment is reached align shim with door stop pin holes and replace door stop pin Firmly tighten pin in place 90 stop farthest from unit 120 stop closest to unit Performance Checklist Verify cabinet size Verify electrical supply and water supply if applicable Install anti tip device s and verify unit is secure Position unit in cutout level at desired height a...

Страница 17: ...e cellar are located on the right wall in the bottom zone Record the information indicated below You will need it if service is ever required Model number ____________________________________________________________________________________ Serial number _____________________________________________________________________________________ Date of purchase ___________________________________________...

Страница 18: ...35 34 ...

Отзывы: