Viking FBI-1A Скачать руководство пользователя страница 3

If required, these optional relay contacts can control your paging system. The contacts can be set to activate
during page playback or during recording and playback (see 

Programming

section 

C

)

.

The 

FBI-1A

is capable of cancelling a page in progress. Connect the 

Cancel Page Input

to a normally open

remote switch or button at the receptionist’s desk. Momentarily pressing the button will cancel the page in progress
(during recording or playback

).

Connect the 

Record Page Input

to the normally open paging control contact of your phone system. Place the

VOX sensitivity POT in the “MIN” position. The 

FBI-1A

will record the page while the contact closure is maintained.

Note: 

Using the Record Page Input is preferred over using the VOX circuit to control recording

.

The 

FBI-1A

has a POT for adjusting pre-page

and post-page alert tone levels (see diagram,
right

).

Rotate the 

Paging Volume

POT clockwise to

increase the paging volume and counter-
clockwise to decrease the paging volume (see
diagram, right).

D.  Paging Control Output

E.  Cancel Page Input

F.  Record Page Input

G.  Page Alert Tone Volume

H.  Paging Volume

I.  Page LED

B.  Paging Port Mode

A.  Trunk Port Mode

Operation

Important:

The 

MODE SWITCH

must be in the 

TRUNK PORT

position.

1. 

Access the phone system’s trunk port that is interfaced to the 

FBI-1A

.

2. 

Announce the page.

3. 

Hang-up.

Note:

The 

FBI-1A

will record the entire time the trunk port is off hook. It is important that you hang-up immediately

after announcing the page to avoid recording silence.

Important:

The 

MODE SWITCH

must be in the 

PAGING PORT

position.

1.

Access the phone system’s paging port.

2. 

Announce the page.

3. 

Hang-up.

If you are using the 

Record Page Input 

(see 

Programming

section 

F

), the 

FBI-1A

will record the entire time

you are off hook on the paging port. It is important to hang-up immediately after announcing the page to avoid
recording silence.

If you are NOT using the 

Record Page Input

, the 

FBI-1A

’s VOX (voice activated recording) circuit will sense the

paging audio and automatically begin recording the page. The 

FBI-1A

will continue to record until 2 seconds of

silence is detected. The 

FBI-1A

will then playback the recorded page. In this mode, the VOX sensitivity may

require adjustment (see 

Programming

section 

B

).

Note:

For both modes, if the page exceeds the recording time, you will hear two error beeps in the handset

before the page is played. On systems that do not use the paging control output (see 

Programming

section 

D

),

the error beeps will play over the paging system before the page.

LED lights steady when the paging port is not accessed, the VOX sensitivity is set too high and should be decreased
until the LED turns off (see 

Programming

section 

B

). During playback in either mode, the LED will light steady for

the entire duration of the message playback.

VIKING

©

MODEL FBI-1A

PAGING

VOLUME

VOX

SENSITIVITY

POWER 13.8V AC 

PAGING

PORT

TRUNK

PORT

PAGE
TONE

VOL

1

2

3

4

5

6

7

8

9 10

PAGING

INPUT

600 OHM

AUDIO OUT 

COMMON

RECORD PAGE  

CANCEL PAGE

MODE SWITCH

RECORD TIME 

SLP-1 MODE 

PAGE REPEAT

PRE-PAGE TONE

 POST PAGE TONE 

PAGING

CONTROL

OUTPUT

MIN

MAX

MIN

MAX

DIGITAL ANTI-FEEDBACK

    PAGING INTERFACE

1 2 3 4 5

VIKING

ELECTRONICS

HUDSON, WI 54016 

N.O. 

COM

N.C. 

PAGING

VOLUME

     MAX

MIN  

VOX

SENSITIVITY

     MAX

MIN  

Decrease Increase 

Page Alert Tone Volume

This is a recording and playback indicator. When recording in the 

Trunk

Port

mode, the LED will light steady while the phone system’s trunk port is

accessed. When recording in the 

Paging Port 

mode, the LED can be used

as a maximum VOX sensitivity adjustment indicator; the LED should flash
only when the paging port is accessed and paging audio is present, if the

3