![Viking FBI-1A Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/viking/fbi-1a/fbi-1a_product-manual_1025683003.webp)
If required, these optional relay contacts can control your paging system. The contacts can be set to activate
during page playback or during recording and playback (see
Programming
section
C
)
.
The
FBI-1A
is capable of cancelling a page in progress. Connect the
Cancel Page Input
to a normally open
remote switch or button at the receptionist’s desk. Momentarily pressing the button will cancel the page in progress
(during recording or playback
).
Connect the
Record Page Input
to the normally open paging control contact of your phone system. Place the
VOX sensitivity POT in the “MIN” position. The
FBI-1A
will record the page while the contact closure is maintained.
Note:
Using the Record Page Input is preferred over using the VOX circuit to control recording
.
The
FBI-1A
has a POT for adjusting pre-page
and post-page alert tone levels (see diagram,
right
).
Rotate the
Paging Volume
POT clockwise to
increase the paging volume and counter-
clockwise to decrease the paging volume (see
diagram, right).
D. Paging Control Output
E. Cancel Page Input
F. Record Page Input
G. Page Alert Tone Volume
H. Paging Volume
I. Page LED
B. Paging Port Mode
A. Trunk Port Mode
Operation
Important:
The
MODE SWITCH
must be in the
TRUNK PORT
position.
1.
Access the phone system’s trunk port that is interfaced to the
FBI-1A
.
2.
Announce the page.
3.
Hang-up.
Note:
The
FBI-1A
will record the entire time the trunk port is off hook. It is important that you hang-up immediately
after announcing the page to avoid recording silence.
Important:
The
MODE SWITCH
must be in the
PAGING PORT
position.
1.
Access the phone system’s paging port.
2.
Announce the page.
3.
Hang-up.
If you are using the
Record Page Input
(see
Programming
section
F
), the
FBI-1A
will record the entire time
you are off hook on the paging port. It is important to hang-up immediately after announcing the page to avoid
recording silence.
If you are NOT using the
Record Page Input
, the
FBI-1A
’s VOX (voice activated recording) circuit will sense the
paging audio and automatically begin recording the page. The
FBI-1A
will continue to record until 2 seconds of
silence is detected. The
FBI-1A
will then playback the recorded page. In this mode, the VOX sensitivity may
require adjustment (see
Programming
section
B
).
Note:
For both modes, if the page exceeds the recording time, you will hear two error beeps in the handset
before the page is played. On systems that do not use the paging control output (see
Programming
section
D
),
the error beeps will play over the paging system before the page.
LED lights steady when the paging port is not accessed, the VOX sensitivity is set too high and should be decreased
until the LED turns off (see
Programming
section
B
). During playback in either mode, the LED will light steady for
the entire duration of the message playback.
VIKING
©
MODEL FBI-1A
PAGING
VOLUME
VOX
SENSITIVITY
POWER 13.8V AC
PAGING
PORT
TRUNK
PORT
PAGE
TONE
VOL
1
2
3
4
5
6
7
8
9 10
PAGING
INPUT
600 OHM
AUDIO OUT
COMMON
RECORD PAGE
CANCEL PAGE
MODE SWITCH
RECORD TIME
SLP-1 MODE
PAGE REPEAT
PRE-PAGE TONE
POST PAGE TONE
PAGING
CONTROL
OUTPUT
MIN
MAX
MIN
MAX
DIGITAL ANTI-FEEDBACK
PAGING INTERFACE
1 2 3 4 5
VIKING
ELECTRONICS
HUDSON, WI 54016
N.O.
COM
N.C.
PAGING
VOLUME
MAX
MIN
VOX
SENSITIVITY
MAX
MIN
Decrease Increase
Page Alert Tone Volume
This is a recording and playback indicator. When recording in the
Trunk
Port
mode, the LED will light steady while the phone system’s trunk port is
accessed. When recording in the
Paging Port
mode, the LED can be used
as a maximum VOX sensitivity adjustment indicator; the LED should flash
only when the paging port is accessed and paging audio is present, if the
3