2
Installation
VIKING
©
MODEL FBI-1A
PAGING
VOLUME
VOX
SENSITIVITY
POWER 13.8V AC
PAGING
PORT
TRUNK
PORT
PAGE
TONE
VOL
1
2
3
4
5
6
7
8
9 10
PAGING
INPUT
600 OHM
AUDIO OUT
COMMON
RECORD PAGE
CANCEL PAGE
MODE SWITCH
RECORD TIME
SLP-1 MODE
PAGE REPEAT
PRE-PAGE TONE
POST PAGE TONE
PAGING
CONTROL
OUTPUT
MIN
MAX
MIN
MAX
DIGITAL ANTI-FEEDBACK
PAGING INTERFACE
1 2 3 4 5
VIKING
ELECTRONICS
HUDSON, WI 54016
N.O.
COM
N.C.
Mode Switch
(see
Programming
section
A
)
Page LED
- Lights during recording and playback
(see
Programming
section
I
)
Page Alert Tone Volume
(see
Programming
section
G
)
DIP Switches
(See
Programming
section
C
)
Secondary Paging Control Output
(see
Programming
section
D
)
N.C. relay contact
COM relay contact
N.O. relay contact
Paging Control Output
(see
Programming
section
D
)
N.C. relay contact
COM relay contact
N.O. relay contact
Cancel Page
(see
Programming
section
E
)
Record Page
(see
Programming
section
F
)
Common
To Paging System
(not included)
600 ohm paging port
or unused trunk port
Phone System
(PABX/KSU)
13.8V AC
Adapter
(included)
120V AC
600 ohm page output
(to paging amp input)
VOX Sensitivity -
Voice Operated
Recording Adjustment
(see
Programming
section
B
)
Paging Volume
(see
Programming
section
H
)
IMPORTANT:
Electronic devices are susceptible to lightning and power station electrical surges from both the AC
outlet and the telephone line. It is recommended that a surge protector be installed to protect against such surges.
Programming
A. Mode Switch
B. VOX Sensitivity
In the Trunk Port position, 24V talk battery is supplied for connecting the
FBI-1A
paging input to a phone system’s
unused trunk port. In the Paging Port position, a 600 ohm audio input is supplied for connecting to a phone
system’s paging port output.
If the
FBI-1A
is installed on a phone system’s paging port that does not supply a page control contact (normally
open relay contact that closes while the paging port is activated) the VOX (Voice Operated Recording) feature
may be used. The VOX sensitivity may require adjustment. Rotate the POT clockwise to increase the sensitivity
for low level input signals (see Programming section I).
Note:
The VOX (Voice Operated Recording) feature is not used in the trunk mode or when a page control contact
is connected to the record page input of the
FBI-1A
to trigger the recording. In these applications, set the VOX
sensitivity to the minimum level.
C. DIP Switch programming
Switch
Position
Description
1
ON
Enables the post page tone - a high tone after the page
1
OFF
Disables the post page tone)
2
ON
Enables the pre-page tone - a low tone before the page)
2
OFF
Disables the pre-page tone
3
ON
Enables page repeat - the message is played twice
3
OFF
Disables page repeat
4
ON
Enables
SLP-1
mode - the paging control outputs activate
during record and playback
4
OFF
Disables
SLP-1
mode - the paging control outputs activate
during playback only
5
ON
Standard record time - 16 seconds (high quality/80K)
5
OFF
Extended record time - 32 seconds (low quality/40K
)
VIKING
©
MODEL FBI-1A
PAGING
VOLUME
VOX
SENSITIVITY
POWER 13.8V AC
PAGING
PORT
TRUNK
PORT
PAGE
TONE
VOL
1
2
3
4
5
6
7
8
9 10
PAGING
INPUT
600 OHM
AUDIO OUT
COMMON
RECORD PAGE
CANCEL PAGE
MODE SWITCH
RECORD TIME
SLP-1 MODE
PAGE REPEAT
PRE-PAGE TONE
POST PAGE TONE
PAGING
CONTROL
OUTPUT
MIN
MAX
MIN
MAX
DIGITAL ANTI-FEEDBACK
PAGING INTERFACE
1 2 3 4 5
VIKING
ELECTRONICS
HUDSON, WI 54016
N.O.
COM
N.C.
1 2 3 4 5
ON
OFF
DIP Switches
Note: DIP Switches are
shown in the factory