VIKING TECHNICAL SUPPORT 1.800.908.0884
2 2
Two Wire Communication
!
IMPORTANT:
DO NOT run the Master/Slave communication cable in the same conduit
or within 12” of 115 - 230V power supply cables.
!
Technical Tip:
DO NOT set the “Timer” and/or “Overlap” features on both operators
Control Boards. Only turn these features on at the Master Control Board.
MASTER/SLAVE SETUP
SLAVE MODE
ON
Step 3
At the Slave Operator:
Turn ON the SLAVE MODE
Feature:
• Toggle the “Diagnose”
button until you see
SLAVE
MODE
on the LCD Display.
• Default setting is OFF.
• Press and hold the “Stop”
button.
• Toggle the “Diagnose”
button once.
• The feature should now be
displayed as “ON”.
Step 2
At the Master Operator:
Connect the entrapment
protection sensor(s)
as
described on page 11.
Drain Wire
Shielded
Cable
Condui
t
CABLE REQUIREMENTS:
• 2 Conductor (wire)
• 18 AWG or better
• Shielded (overall foil)
• Drain Wire (bare wire)
MS1
MS2
MS1
MS2
Step 1
Connect shielded cable to “Master/Slave” connectors at the control boards