VIKING TECHNICAL SUPPORT 1.800.908.0884
1 3
!
CAUTION: To Reduce the Risk of Fire or Injury to Persons:
!
WARNING: For use with gates at a maximum 1500 lbs. in weight or 16 ft. in length.
IMPORTANT INSTALLATION INFORMATION
1000 lb.
Locate Control Buttons:
1. Within sight of the gate,
2. At a minimum height of 5 feet
so small children are not able to
reach it; and
3. At least 6 feet away from all
moving parts of the gate.
DO NOT allow pedestrian use of this gate
DO NOT install the gate operator to lift gates
16 ft.
1500 lb.
12 ft.
Specifications:
UL 325 Classifcation:
Class I, II, III and IV
*Refer to page 9
Maximum Gate Length:
16 ft. / 12 ft.
Maximum Gate Weight:
1000 lb. / 1500 lb.
Operating Temperature:
-20°F (-28°C) to 160°F (71°C)
Power Requirements:
120VAC / 240VAC (5.5* Amp / 1.25 Amp)
*Includes 3 amp load on receptacle
Single Phase (50Hz / 60Hz)
Alternative Power
24VAC / VDC (60VA) or Solar